GW-16
POWER WINDOW SYSTEM
Revision: 2006 December 2006 FX35/FX45
System DescriptionNIS001QQ
Power is supplied at all time
through 50A fusible link (letter M , located in the fuse and fusible link box)
to BCM terminal 55, and
through BCM terminal 54
to power window main switch terminal 19
to front power window switch (passenger side) terminal 10.
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 42.
With ignition switch in ON or START position,
Power is supplied
through 15A fuse [No. 1 , located in the fuse block (J/B)]
to BCM terminal 38, and
trough BCM terminal 53
to power window main switch terminal 10
to rear power window switch (LH and RH) terminal 1.
Ground supplied
to BCM terminal 49 and 52
through body grounds M35, M45 and M85.
to power window main switch terminal 17
through body grounds M35, M45 and M85.
to front power window switch (passenger side) terminal 11
through body grounds M35, M45 and M85.
MANUAL OPERATION
Front Driver Side Door
WINDOW UP
When the front LH switch in the power window main switch is pressed in the up position,
Power is supplied
through power window main switch terminal 8
to front power window motor (driver side) terminal 2.
Ground is supplied
to front power window motor (driver side) terminal 1
through power window main switch terminal 11.
Then, the motor raises the window until the switch is released.
WINDOW DOWN
When the front LH switch in the power window main switch is pressed in the down position
Power is supplied
through power window main switch terminal 11
to front power window motor (driver side) terminal 1.
Ground is supplied
to front power window motor (driver side) terminal 2
through power window main switch terminal 8.
Then, the motor lowers the window until the switch is released.
Front Passenger Side Door
FRONT POWER WINDOW SWITCH (PASSENGER SIDE) OPERATION
WINDOW UP
When the front power window switch (passenger side) is pressed in the up position
Power is supplied
through front power window switch (passenger side) terminal 8
to front power window motor (passenger side) terminal 2.
POWER WINDOW SYSTEM GW-19
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2006 December 2006 FX35/FX45
POWER WINDOW SERIAL LINK
Power window main switch, front power window switch (passenger side), and BCM transmit and receive the
signal by power window serial link.
The under mentioned signal is transmitted from BCM to power window main switch and front power window
switch (passenger side)
Keyless power window down signal.
The under mentioned signal is transmitted from power window main switch to front power window switch (pas-
senger side)
Front passenger side door window operation signal.
Power window control by key cylinder switch signal.
Power window lock signal.
Retained power operation signal.
POWER WINDOW LOCK
The power window lock is designed to lock operation of all windows except for driver side door window.
When the lock position, ground of the rear power window switches in the power window main switch is discon-
nected. The power window lock signal is transmitted to front power window switch (passenger side) by power
window serial link. This prevents the power window motors from operating.
RETAINED POWER OPERATION
When the ignition switch is turned to the OFF position from ON or START position.
Power is supplied for 45 seconds
through BCM terminal 53
to power window main switch terminal 10
to rear power window switch (LH and RH) terminals 1.
When power and ground are supplied, the BCM continues to be energized, and the power window can be
operated.
The retained power operation is canceled when the driver or passenger side door is opened.
RAP signal period can be changed by CONSULT-II. Refer to GW-29, "
CONSULT-II Function (BCM)" .
ANTI-PINCH SYSTEM
Power window main switch and front power window switch (passenger side) monitors the power window motor
operation and the power window position (full closed or other) for driver side and passenger side power win-
dow by the signals from encoder and limit switch in front power window motor (driver side and passenger
side).
When power window main switch detects interruption during the following close operation,
automatic close operation when ignition switch is in the “ON” position
automatic close operation during retained power operation
manual close operation during retained power operation
power window main switch or front power window switch (passenger side) controls each power window motor
for open and the power window will be lowered about 150 mm (5.91 in).
POWER WINDOW CONTROL BY THE KEY CYLINDER SWITCH
When ignition key switch is OFF, front power window can be opened or closed by turning the key cylinder
switch UNLOCK / LOCK position more than 1.5 second over condition.
Power window can be opened as the door key cylinder is kept fully turning to the UNLOCK position.
Power window can be closed as the door key cylinder is kept fully turning to the LOCK position.
The power window DOWN stops when the following operations are carried out.
While performing open / close the window, power window is stopped at the position as the door key cylin-
der is placed on NEUTRAL.
When the ignition switch is turned ON while the power window DOWN is operated.
GW-26
POWER WINDOW SYSTEM
Revision: 2006 December 2006 FX35/FX45
Terminal and Reference Value for BCMNIS001QV
Te r -
minal Wire
color Item Signal
Input/Output Condition Voltage [V]
(Approx.)
12 P/B Front door switch
passenger side signal Input ON (Open) 0
OFF (Close) Battery voltage
22 OR Power window serial link Input/Output IGN SW ON or power window
timer operating.
38 W/L Ignition switch
(ON or START) Input Ignition switch
(ON or START position) Battery voltage
39 L CAN - H Input/Output — —
40 P CAN - L Input/Output — —
42 L/R Power source (Fuse) Input — Battery voltage
49 B Ground (signal) — — 0
52 B Ground (power) — — 0
53 Y/B Rap signal Output IGN SW ON Battery voltage
Within 45 second after ignition
switch is turned to OFF Battery voltage
When driver side or passen-
ger side door is open in power
window timer is operates 0
54 W Power window power supply Output — Battery voltage
55 G Power source
(Fusible link) Input — Battery voltage
62 W Front door switch
driver side signal Input ON (Open) 0
OFF (Close) Battery voltage
PIIA2344J
POWER WINDOW SYSTEM GW-27
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2006 December 2006 FX35/FX45
Terminal and Reference Value for Power Window Main Switch NIS001QW
Te r -
minal Wire
color Item Signal
Input/Output Condition Voltage [V]
(Approx.)
1Y Rear LH power window
UP signal Output When rear LH switch in
power window main switch is
UP at operated. Battery voltage
2SB Limit switch and encoder
ground —— 0
3R Rear LH power window
DOWN signal Output When rear LH switch in
power window main switch is
DOWN at operated. Battery voltage
4P Door key cylinder switch
LOCK signal InputKey position
(Neutral → Locked) 5
→ 0
5G Rear RH power window
DOWN signal Output When rear RH switch in
power window main switch is
DOWN at operated. Battery voltage
6OR Door key cylinder switch
UNLOCK signal InputKey position
(Neutral → Unlocked) 5
→ 0
7LG Rear RH power window
UP signal Output When rear RH switch in
power window main switch is
UP at operated. Battery voltage
8L Front driver side
power window motor UP signal Output When front LH switch in
power window main switch is
UP at operated Battery voltage
9 GY Limit switch signal Input Driver side door window is
between fully-open and just
before fully-closed position
(ON) 0
Driver side door window is
between just before fully-
closed position and fully-
closed position (OFF) 5
10 BR Rap signal Input IGN SW ON Battery voltage
Within 45 second after ignition
switch is turned to OFF Battery voltage
When driver side or passenger
side door open in power win-
dow timer is operates 0
11 B Front driver side
power window motor DOWN
signal Output When front LH switch in
power window main switch is
DOWN at operated Battery voltage
13 PU Encoder pulse signal Input When power window motor
operates.
14 Y Power window serial link Input/Output IGN SW ON or power window
timer operating.
OCC3383D
PIIA2344J
GW-28
POWER WINDOW SYSTEM
Revision: 2006 December 2006 FX35/FX45
Terminal and Reference Value for Front Power Window Switch (Passenger Side) NIS001QX
15 W Encoder power supply Output When ignition switch ON or
power window timer operates 10
17 B Ground — — 0
19 W Battery power supply Input — Battery voltage
Te r -
minal Wire
color Item Signal
Input/Output Condition Voltage [V]
(Approx.)
Te r -
minal Wire
color Item
Signal
Input/Output Condition
Voltage [V]
(Approx.)
3SB Limit switch and encoder
ground Input — 0
4 R Encoder power supply Output When ignition switch ON or
power window timer operates 10
8L Front passenger side
power window motor UP signal Output
When power window motor is
UP at operated. Battery voltage
9G Front passenger side
power window motor DOWN
signal Output
When power window motor is
DOWN at operated. Battery voltage
10 W Battery power supply Input — Battery voltage 11 B Ground — — 0
12 PU Encoder pulse signal Input When power window motor
operates.
15 GY Limit switch signal Input Passenger side door window
is between fully-open and just
before fully-closed position
(ON) 0
Passenger side door window
is between just before fully-
closed position and fully-
closed position (OFF) 5
16 Y Power window serial link Input/Output IGN SW ON or power window
timer operating.
OCC3383D
PIIA2344J
POWER WINDOW SYSTEM GW-29
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2006 December 2006 FX35/FX45
CONSULT-II Function (BCM)NIS001R3
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II OPERATION
Refer to GI-38, "CONSULT-II Start Procedure" .
ACTIVE TEST
WORK SUPPORT
DATE MONITOR
BCM diagnostic test item Check item diagnostic test mode Content RETAINED PWR Work support Changes setting of each function.
Data monitor Displays the input data of BCM in real time.
Active test Gives a drive signal to a load to check the operation.
Test Item Description
RETAINED PWR This test is able to supply RAP signal (power) from BCM (body control module) to power window
system and power sunroof system (if equipped). Those systems can be operated when turning on
“RETAINED PWR” on CONSULT-II screen even if the ignition switch is turned OFF.
NOTE:
During this test, CONSULT-II can be operated with ignition switch in “OFF” position. “RETAINED
PWR” should be turned “ON” or “OFF” on CONSULT-II screen when ignition switch is ON. Then
turn ignition switch OFF to check retained power operation. CONSULT-II might be stuck if
“RETAINED PWR” is turned to “ON” or “OFF” on CONSULT-II screen when ignition switch is OFF.
Work item Description
RETAINED PWR Rap signal’s power supply period can be changed by mode setting. Selects rap signal’s power
supply period between three steps
MODE1 (45 sec.) / MODE2 (OFF) / MODE 3 (2 min.).
Work item Description
IGN ON SW Indicates (ON / OFF) condition of ignition switch
DOOR SW–DR Indicates (ON / OFF) condition of front door switch driver side
DOOR SW–AS Indicates (ON / OFF) condition of front door switch passenger side
GW-32
POWER WINDOW SYSTEM
Revision: 2006 December 2006 FX35/FX45
Check BCM Power Supply and Ground CircuitNIS001R7
1. CHECK FUSE
Check 15A fuse [No. 1, located in fuse block (J/B)]
Check 15A fuse [No. 22, located in fuse block (J/B)]
Check 50A fusible link (letter M , located in the fuse and fusible link box).
NOTE:
Refer to GW-15, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown out, be sure to eliminate cause of malfunction before installing new fuse. Refer to
PG-3, "
POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
Check voltage between BCM connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check BCM power supply circuit for open or short.
3. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check continuity between BCM connector M4 terminal 49, 52 and ground.
OK or NG
OK >> Power supply and ground circuit are OK.
NG >> Check BCM ground circuit for open or short.
Connector Terminal (Wire color)
Condition of
ignition switch Voltage [V]
(Approx.)
(+) (–)
M3 38 (W/L) Ground ON
Battery
voltage
M4 42 (L/R)
OFF
55 (G)
PIIB1383E
49 (B) – Ground : Continuity should exist.
52 (B) – Ground : Continuity should exist.
PIIA6161E
POWER WINDOW SYSTEM GW-33
C
D E
F
G H
J
K L
M A
B
GW
Revision: 2006 December 2006 FX35/FX45
Check Power Window Main Switch Power Supply Circuit NIS001R8
1. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between power window main switch connector D6, D7 terminal 10, 19 and ground.
OK or NG
OK >> Power window main switch power supply and ground circuit are OK.
NG >> GO TO 2.
2. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect power window main switch connector.
3. Check continuity between power window main switch connector D7 terminal 17 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK HARNESS CONTINUITY
1. Disconnect BCM connector.
2. Check continuity between BCM connector M4 terminal 53, 54 and power window main switch connector D6, D7 terminal 10,
19.
3. Check continuity between BCM connector M4 terminal 53, 54 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness. 10 (BR) – Ground : Battery voltage
19 (W) – Ground : Battery voltage
PIIA4171E
17 (B) – Ground : Continuity should exist.
PIIA4172E
53 (Y/B) – 10 (BR) : Continuity should exist.
54 (W) – 19 (W) : Continuity should exist.
53 (Y/B) – Ground : Continuity should not exist.
54 (W) – Ground : Continuity should not exist.
PIIA6280E