Page 52 of 64
ZKE - 52
ALARM INDICATION
When the alarm is triggered, the siren will sound for 30 seconds. At the same time the low
beam headlights and four way flashers will flash for 5 minutes. The GM signals the the LCM
III via the K bus -- I bus to flash the lights.
Following an alarm trigger, the system will reset and trigger again if further tampering is
done to the vehicle.
DWA LED STATUS
DWA STATUS DWA LED CONDITION
Disarmed OFF
Armed Continual slow flash
Armed with one or more monitored Rapid flash for 10 seconds,
inputs not in closed position then continual slow flash.
(ie: trunk not fully closed, etc)
Alarm activated Rapid flash for 5 minutes,
then continual slow flash.
Rearmed in less then 10 seconds. ON for 1 second
Disarmed after activated alarm Rapid flash for 10 seconds,
then OFF.
Page 61 of 64
GENERAL FUNCTIONS OF ZKE III
CONSUMER CUT OFF
The interior lights are connected to the consumer cut out circuit. These consumers are con-
nected to KL 30 and can remain on if one of the control switches are left on. This would
prevent the ZKE from going into the sleep mode. However, the consumer cut off will switch
Kl 30, to the interior lighting, off after 16 minutes.
OVERLOAD PROTECTION
The seat and steering column motors are provided operating power through the consumer
cutoff / overload protection relay module as on the E38. The consumer cutoff signal from
the GM signals the relay to maintain operating power to the consumers.
If an overload condition exists, the relay module detects the increase in amperage and
opens the relay. The relay module is located in the electrical carrier forward of the glove
box.
ZKE -61
Page 62 of 64

62
SLEEP MODE
To lower the constant battery draw when the vehicle is parked, The complete ZKE system
will go into the “Sleep Mode” 16 minutes after the ignition has been switched off and no
further ZKE function is active.
Approximate X5 Battery draw: • Ignition switch off = approx 750 mA.
• One minute after = approx. 560 mA.
• After 16 minutes (sleep mode) = approx. 18 mA.
All modules in the ZKE system will go into the sleep mode. The P-Bus remains active, how-
ever no data transfer takes place until a wake-up request is received. The general module,
door modules or keyless remote module can wake the system up and put the ZKE back
on line. The K-Bus is not active in the sleep mode, however the GM III of Remote Entry
Module can put the K-Bus back on-line with a wake-up request.
SLEEP MODE CRITERIA: KL R, 15 OFF and no further function activated for 16 minutes.
WAKE UP CRITERIA: KL R or 15 “ON” or a change in one of the signal states listed below.
SIGNAL ACTIVITY ORIGINATING
MODULE
K-BUS High General Module
Door jamb switches (possibility of 4) Low “
Trunk lid lock cylinder microswitch High “
Trunk lid pushbutton microswitch Low “
Interior Trunk lid pushbutton microswitch Low “
Central locking button Low “
Hood microswitch Low “
Trunk Lid microswitch Low “
Interior light switch Low “
FIS sensor Low “
Tilt Alarm sensor Low “
FBZV operational signal High FBZV Module
Driver’s door lock microswitch - (lock) High PM-FT/SB
““““ - (unlock) High “
Passenger door lock microswitch - (lock) High PM-BT
““““ - (unlock) High “
Tailgate
Tailgate
Tailgate
Tailgate
UIS