YAMAHA WR 250F 2005  Manuale duso (in Italian) MAINTENANCE SPECIFICATIONS
2 - 10
SPEC
Part to be tightened Thread size Q’tyTightening torque
Nm m·kg ft·lb
Spark plug M10S × 1.0 1 13 1.3 9.4
Camshaft cap M6 × 1.0 10 10 1.0 7.2
Cylinder head b

Page 90 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) MAINTENANCE SPECIFICATIONS
2 - 11
SPEC
NOTE:
 - marked portion shall be checked for torque tightening after break-in or before each race. Silencer M8 × 1.25 2 35 3.5 25
Silencer clamp M8 × 1.25 1 16

Page 91 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) MAINTENANCE SPECIFICATIONS
2 - 12
SPEC
CHASSIS
Item Standard Limit
Steering system:
Steering bearing type Taper roller bearing ----
Front suspension: USA, CDN EUROPE AUS, NZ, ZA
Front fork travel 300

Page 96 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) MAINTENANCE SPECIFICATIONS
2 - 17
SPEC
EC212300
ELECTRICAL
Item Standard Limit
Ignition system:
Advancer type Electrical ----
CDI:
Pickup coil resistance (color) 248 ~ 372 Ω at 20°C (68 °F) 
(Whit

Page 97 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) MAINTENANCE SPECIFICATIONS
2 - 18
SPEC
NOTE:
Tighten the rotor nut to 65 Nm (6.5 m  kg, 47 ft  lb), loosen and retighten the rotor nut to 65 Nm
(6.5 m  kg, 47 ft  lb). Starter relay:
Model/manufac

Page 111 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) CARACTERISTIQUES D’ENTRETIEN
2 - 32
SPEC
Roue: USA, CDN, ZA EUROPE, AUS, NZ
Type de roue avant Roue à rayons← ----
Type de roue arrière Roue à rayons← ----
Taille/matériau de la jante avant

Page 176 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) SPEC
2 - 97
CABLE ROUTING DIAGRAM
EC240000
CABLE ROUTING DIAGRAM
1Fuel tank breather hose
2Oil tank breather hose
3Clamp
4Diode
5Wire harness
6Hot starter cable
7Throttle position sensor lead
8Neutral

Page 178 of 864

YAMAHA WR 250F 2005  Manuale duso (in Italian) SPEC
2 - 99
CABLE ROUTING DIAGRAM
ÊFasten the diode (at the white tape), rectifier/regulator lead,
CDI unit lead (at the protecting tube) and AC magneto coupler
(connected to the CDI unit).
ËFasten