YH4
GRAND
VITARA
Terminal
Switch
Type 1
Type 2
1. Door lock switch
2. Door lock switch coupler
Terminal
Switch
8D-20 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR LOCK SYSTEM (IF KEYLESS
ENTRY IS NOT EQUIPPED)
INSPECTION
POWER DOOR LOCK SWITCH
Check for continuity between terminals at each switch position as
shown below.
Type 1
ALK
LOCK
NEUTRAL
UNLOCK
Type 2
ABF
LOCK
OFF
UNLOCK
POWER DOOR LOCK CONTROLLER (CANVAS TOP
MODEL)
1) Disconnect power door lock controller coupler.
2) Connect (+) wire and (±) wire of 12 V battery to terminal ªAº, ªEº
and ªFº as shown in figure.
3) Disconnect cord from terminal ªEº and connect it to terminal ªGº.
4) Repeat Steps 2) and 3) several times and if relay operation is
heard every time, it means that controller is operating.
POWER DOOR LOCK CONTROLLER (HARD TOP MODEL)
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, power door lock
controller is OK. If check result is not satisfactory, go to next Step 3).
3) Disconnect negative cable at battery.
4) Disconnect coupler of power door lock controller.
5) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is not satisfactory, repair circuit and recheck.
If check result is satisfactory, go to next Step 6).
YH4
GRAND
VITARA
Terminal
Key
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-21
6) Connect negative cable at battery.
7) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimecontinuity
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is not satisfactory, repair circuit and recheck.
If check result is satisfactory, replace controller.
KEY CYLINDER SWITCH (DRIVER SIDE)
Check for continuity between terminals according to the key action
shown below.
321
LOCK
OFF
UNLOCK
YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-23
POWER DOOR LOCK AND KEYLESS ENTRY SYSTEM (IF KEYLESS ENTRY IS
EQUIPPED)
SYSTEM INSPECTION
STEPACTIONYESNO
1Check power door lock operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 2.Go to Step 3.
2Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 4.Go to Step 6.
3Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 5.Go to Step 7.
4Check hazard warning lights operation referring to
its INSPECTION in this section.
Is this operation OK?This system is OK.Go to Step 10.
5Check door lock key and power door lock switch
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
6Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
7Check power door lock actuator circuit referring to
its INSPECTION in this section.
Is this circuit OK?Go to Step 8.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 8.
8Check power supply and grounding circuit
referring to its INSPECTION in this section.
Is this circuit OK?Go to Step 9.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 9.
91) Check door lock key and power door lock
switch circuit referring to its INSPECTION in
this section.
2) Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Are these circuits OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
YH4
GRAND
VITARA
8D-24 WINDOWS, MIRRORS, SECURITY AND LOCKS
STEPACTIONYESNO
10Check that hazard warning lights flash with hazard
switch ON.
Is check result OK?Go to Step 11.Refer to ªTurn Signal
and Hazard Warning
Lightsº in DIAGNOSIS
and repair.
And go to Step 4.
11Check door knob switch and turn signal relay
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
POWER DOOR LOCK OPERATION
INSPECTION
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
KEYLESS ENTRY OPERATION
INSPECTION
1) With the IG switch OFF and all doors closed, push LOCK button
on transmitter. Check all power doors are locked.
2) Push UNLOCK button on transmitter. Check only driver side
power door is unlocked.
3) Push UNLOCK button on transmitter again within 5 seconds.
Check all power doors are unlocked.
But if any door is not opened within 30 seconds after power
door(s) unlocked, all power doors are locked again automatical-
ly.
If check result of Step 1) to Step 3) is satisfactory, this operation is
OK.
HAZARD WARNING LIGHTS OPERATION
INSPECTION
1) Check that hazard warning lights flash one time when power
doors are locked by pushing LOCK button on transmitter.
2) Check that hazard warning lights flash two times when power
door(s) is (are) unlocked by pushing UNLOCK button on trans-
mitter.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
YH4
GRAND
VITARA
8G
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-1
GENERAL DESCRIPTION8G- 2 . . . . . . . . . . . . . .
Ignition Key 8G- 3. . . . . . . . . . . . . . . . . . . . . . . . . .
Coil Antenna 8G- 3. . . . . . . . . . . . . . . . . . . . . . . . .
Immobilizer Control Module 8G- 4. . . . . . . . . . . .
ECM/PCM 8G- 4. . . . . . . . . . . . . . . . . . . . . . . . . . .
On-Board Diagnostic System
(Self-Diagnosis Function) 8G- 4. . . . . . . . . . . . .
DIAGNOSIS8G- 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Precautions in Diagnosing Troubles 8G- 6. . . . .
Diagnostic Flow Table
Diagnostic Flow Table
Diagnostic Trouble Code Check
(Immobilizer Control Module) 8G-11. . . . . . . .
Diagnostic Trouble Code Check
(ECM / PCM) 8G-11. . . . . . . . . . . . . . . . . . . . . .
Diagnostic Trouble Code Table 8G-13. . . . . . . . .
TABLE A DTC is not Output
from Diagnostic Output Terminal 8G-14. . . . . . .
TABLE B Immobilizer Indicator Lamp
Check (Immobilizer Indicator Lamp
does not Light at Ignition Switch ON) 8G-15. . .
TABLE C Immobilizer Indicator Lamp
Check (Immobilizer Indicator Lamp
Remains on after Engine Starts) 8G-16. . . . . . .
DTC11 Transponder Code Not Matched8G-17 . .
DTC31 Transponder Code Not
Registered 8G-17. . . . . . . . . . . . . . . . . . . . . . . . .
DTC12 Fault in Immobilizer
Control Module 8G-17. . . . . . . . . . . . . . . . . . . . . .
DTC13 No Transponder Code Transmitted
or Coil Antenna Opened/Shorted 8G-18. . . . . . DTC21 ECM/Immobilizer Control Module
Code Not Matched (Immobilizer Control
Module Side) 8G-20. . . . . . . . . . . . . . . . . . . . . . .
DTC81 (P1623) ECM/Immobilizer
Control Module Code Not Matched
(ECM/PCM Side) 8G-20. . . . . . . . . . . . . . . . . . . .
DTC84 (P1620) ECM/Immobilizer Control
Module Code Not Registered 8G-20. . . . . . . . .
DTC22 Ignition Switch Circuit Open/Short8G-21 . .
DTC23 No ECM/Immobilizer Control
Module Code Transmitted from ECM/
PCM or DLC Circuit Opened/Shorted8G-22 . . . .
DTC83 (P1621) No ECM/Immobilizer
Control Module Code Transmitted from
Immobilizer Control Module or DLC
Circuit Opened/Shorted 8G-22. . . . . . . . . . . . . .
DTC82 (P1622) Fault in ECM/PCM 8G-23. . . . .
Inspection of ECM/PCM, Immobilizer
Control Module and Its Circuit 8G-24. . . . . . . . .
Voltage Check 8G-24. . . . . . . . . . . . . . . . . . . . .
Resistance Check 8G-25. . . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE8G-26 . . . . . . . . . . . . . . . .
Precautions in Handling Immobilizer
Control System 8G-26. . . . . . . . . . . . . . . . . . . . .
Immobilizer Control Module 8G-27. . . . . . . . . . . .
Coil Antenna 8G-27. . . . . . . . . . . . . . . . . . . . . . . . .
HOW TO REGISTER IGNITION KEY8G-28 . . . . .
PROCEDURE AFTER IMMOBILIZER
CONTROL MODULE REPLACEMENT8G-29 . .
PROCEDURE AFTER ECM/PCM
REPLACEMENT8G-30 . . . . . . . . . . . . . . . . . . . . . .
SPECIAL TOOLS8G-30 . . . . . . . . . . . . . . . . . . . . . .
SECTION 8G
IMMOBILIZER CONTROL SYSTEM
(IF EQUIPPED)
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
CONTENTS
YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-17
DTC11 TRANSPONDER CODE NOT MATCHED
DESCRIPTION:
Immobilizer Control Module checks if Transponder code transmitted from ignition key and that registered in Immo-
bilizer Control Module match when ignition switch is ON. If they do not, this DTC is set.
INSPECTION:
Register ignition key with built-in transponder by using Suzuki scan tool (TECH1 cartridge for immobilizer control
system and TECH 1A kit) and performing following steps.
1) Register Transponder code in Immobilizer Control Module by performing procedure described in ªHow to regis-
ter ignition keyº section.
2) Turn ignition switch OFF, then turn it ON and check that DTC11 is not set.
DTC31 TRANSPONDER CODE NOT REGISTERED
DESCRIPTION:
Immobilizer Control Module checks if Transponder code transmitted from ignition key and that registered in Immo-
bilizer Control Module match when ignition switch is ON. If there is no Transponder code registered in Immobilizer
Control Module, this DTC is set.
INSPECTION:
Register ignition key with built-in transponder by using Suzuki scan tool (TECH1 cartridge for immobilizer control
system and TECH 1A kit) and performing following steps.
1) Register Transponder code in Immobilizer Control Module by performing procedure described in ªHow to regis-
ter ignition keyº section.
2) Turn ignition switch OFF, then turn it ON and check that DTC31 is not set.
DTC12 FAULT IN IMMOBILIZER CONTROL MODULE
DESCRIPTION:
This DTC is set when an internal fault is detected in Immobilizer Control Module.
INSPECTION:
STEPACTIONYESNO
11) Ignition switch OFF.
2) Disconnect connectors from Immobi-
lizer Control Module.
3) Check for proper connection to Im-
mobilizer Control Module at all termi-
nals.
Are they in good condition?Substitute a known-good Immobilizer
Control Module and recheck.
NOTE:
After replacing with a known-good
Immobilizer Control Module, register
ECM/Immobilizer Control Module
code in ECM / PCM and Transponder
code and ECM/Immobilizer
Control Module code in Immobilizer
Control Module by performing
procedure described in ªProcedure
after Immobilizer Control Module
Replacementº section.Repair or replace.
YH4
GRAND
VITARA
8G-22 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
A812
To SDM (if equipped with AIRBAG)
To data link connector (DLC)1. Immobilizer Control Module
2. ECM / PCM (j) (i)
(i)
(i)
DTC23 NO ECM/IMMOBILIZER CONTROL MODULE CODE TRANSMITTED
FROM ECM/PCM OR DLC CIRCUIT OPENED/SHORTED
DTC83 NO ECM/IMMOBILIZER CONTROL MODULE CODE TRANSMITTED
(P1621) FROM IMMOBILIZER CONTROL MODULE OR DLC CIRCUIT
OPENED/SHORTED
DESCRIPTION
When the ignition switch is ON, Immobilizer Control Module requests ECM / PCM and ECM / PCM requests Immobi-
lizer Control Module to transmit ECM/Immobilizer Control Module code. If ECM/Immobilizer Control Module code
is not transmitted from ECM / PCM or Immobilizer Control Module, Immobilizer Control Module sets DTC23 and
ECM / PCM sets DTC83 (P1621).
INSPECTION:
STEPACTIONYESNO
1Check voltage between
Immobilizer Control Mod-
ule coupler terminal A8
and body ground with igni-
tion switch turned ON.
Is it 4 ± 5V?Go to Step 2.ª(i)º or ª(j)º wire
short.
21) Disconnect ECM /
PCM coupler with igni-
tion switch turned
OFF.
2) Is there continuity be-
tween Immobilizer
Control Module cou-
pler terminal A8 and
Data link connector
terminal of ECM / PCM
coupler? (For posi-
tions of Data link con-
nector terminal of
ECM / PCM coupler,
refer to Section 6E1 or
6E2.)Poor A8 connection (Immobilizer Control Module) or
Poor Data link connector terminal connection (ECM /
PCM). If connections are OK, substitute a known-good
ECM / PCM or Immobilizer Control Module and re-
check.
NOTE :
After replacing with a known-good ECM / PCM,
register ECM/Immobilizer Control Module code
in ECM / PCM by performing procedure de-
scribed in ªProcedure after ECM / PCM Replace-
mentº section.
After replacing with a known-good Immobilizer
Control Module, register ECM/Immobilizer Control
Module code in ECM / PCM and Transponder code
and ECM/Immobilizer Control Module code in Im-
mobilizer Control Module by performing proce-
dure described in ªProcedure after Immobilizer
Control Module Replacementº section.ª(i)º or ª(j)º wire be-
tween Immobilizer
Control Module and
ECM / PCM open.
Fig. 1 for step 1
1
A8
1. Immobilizer Control Module
1. Immobilizer Control Module coupler disconnected1
A8Connect to Data link connector terminal
of ECM / PCM coupler disconnected
Fig. 2 for step 2
YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-23
DTC82 (P1622) FAULT IN ECM / PCM
DESCRIPTION:
This DTC is set when an internal fault is detected in ECM / PCM.
INSPECTION:
STEPACTIONYESNO
11) Ignition switch OFF.
2) Disconnect connectors from
ECM / PCM.
3) Check for proper connection
to ECM / PCM at all terminals.
Are they in good condition?Substitute a known-good ECM / PCM and
recheck.
NOTE:
After replacing with a known-good ECM /
PCM, register ECM/Immobilizer Control
Module code in ECM / PCM by performing
procedure described in ªProcedure after
ECM / PCM Replacementº section.Repair or replace.