YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-3
BODY VENTILATION
The body ventilation system of this vehicle has a fresh air intake located at the cowl top panel. When fresh air intake
control lever is at FRESH AIR position, ventilating air is drawn into the interior from the cowl center garnish and
drawn out from the ventilator outlet provided at each side body outer panel (both right and left side).
DIAGNOSIS
DIAGNOSIS TABLE
TroublePossible causeRemedy
Heater blower won't
work even when its
switch is ON.Blower fuse blown
Blower resistor faulty
Blower motor faulty
Wiring or grounding faultyReplace fuse to check for short.
Check resistor.
Replace motor.
Repair as necessary.
Incorrect temperature
output.Control cables broken or binding
Air damper broken
Air ducts clogged
Heater radiator leaking or clogged
Heater hoses leaking or cloggedCheck cables.
Repair damper.
Repair air ducts.
Replace radiator.
Replace hoses.
When mode control
switch is changed,
air outlet port is not
changed.Mode control switch faulty
Mode actuator faulty
Fuse blown
Wiring or grounding faulty
Air damper broken
Air ducts cloggedCheck and replace as necessary.
Check and replace as necessary.
Replace fuse to check for short.
Repair as necessary.
Repair damper.
Repair air ducts.
YH4
GRAND
VITARA
1B
AIR CONDITIONING (OPTIONAL) 1B-1
GENERAL DESCRIPTION1B- 3 . . . . . . . . . . . . . .
Identification of Refrigerating System 1B- 3. . . .
Refrigerant Flow of Air Conditioning
System 1B- 4. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Major Components and Location 1B- 5. . . . . . .
DIAGNOSIS1B- 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
General 1B- 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis of Abnormal Noise 1B- 8. . . . . . . . . .
Quickly Checking of Refrigerant Charge
(If Equipped with Sight Glass) 1B-10. . . . . . . . .
Compression System Diagnosis 1B-11. . . . . . . .
Performance Diagnosis 1B-12. . . . . . . . . . . . . . .
Wiring Circuit 1B-16. . . . . . . . . . . . . . . . . . . . . . . .
Inspection of A / C Controller and Its
Circuits 1B-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT RECOVERY,
EVACUATION AND CHARGING1B-23 . . . . . . . .
Operation Procedure for Charging A / C
with Refrigerant 1B-23. . . . . . . . . . . . . . . . . . . . .
Recovery 1B-24. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Evacuating 1B-25. . . . . . . . . . . . . . . . . . . . . . . . . .
Charging 1B-26. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Manifold Gauge Set 1B-29. . . . . . . . .
Leak-Testing Refrigerant System 1B-29. . . . . . .
Liquid Leak Detectors 1B-29. . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE1B-30 . . . . . . . . . . . . . . . .
Precaution 1B-30. . . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Condenser Assembly 1B-33. . . . . . . . . . . . .
Condenser Cooling Fan Assembly 1B-35. . . . . .
SECTION 1B
AIR CONDITIONING (OPTIONAL)
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System:
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
CAUTION:
The air conditioning system of this vehicle uses refrigerant HFC-134a (R-134a).
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using refrigerant CFC-12 (R-12) and the other using refrigerant HFC-134a (R-134a).
Be sure to check which refrigerant is used before any service work including inspection and mainte-
nance. For identification between these two types, refer to the description in page 1B-2.
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
For basic servicing method of the air conditioning system that is not described in this section, refer to AIR CONDI-
TIONING BASIC MANUAL (99520-02130).
CONTENTS
YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
YH4
GRAND
VITARA
1B-8 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS OF ABNORMAL NOISE
There are various types of noise, ranging from those produced in the engine compartment to those from the pas-
senger compartment, also from rumbling noises to whistling noises.
ABNORMAL NOISE FROM COMPRESSOR
ConditionPossible CauseCorrection
During compressor operation, a
rumbling noise is heard
proportional to engine
revolutions.Inadequate clearance in piston
area (piston or swash-plate).Repair or replace compressor as
necessary.
A loud noise is heard at a certain
rpm, disproportionately to engine
revolution.Loose or faulty V-belt.
Loose mounting bolts.Adjust V-belt tension, or
replace belt.
Retighten mounting bolts.
A loud rattle is heard at low
engine rpm.Loose compressor center bolt.Retighten center bolt.
Replace compressor if it was
operated in this condition for a
long time.
ABNORMAL NOISE FROM MAGNETIC CLUTCH
ConditionPossible CauseCorrection
A rumbling noise is heard when
compressor is not operating.Worn or damaged bearings.Replace bearings.
A chattering noise is heard when
compressor is engaged.Faulty clutch gap (excessive).
Worn clutch friction surface.
Compressor oil leaked from shaft
seal, contaminating the friction
surface.Adjust clutch gap.
Replace clutch.
Replace compressor shaft oil
seal.
ABNORMAL NOISE FROM TUBING
ConditionPossible CauseCorrection
A droning noise is heard inside
vehicle, but not particularly
noticeable in engine
compartment.Faulty tubing clamps.
Resonance caused by pulsation
from variations in refrigerant
pressure.Reposition clamps or increase
the number of clamps.
Attach a silencer to tubing, or
modify its position and length.
ABNORMAL NOISE FROM CONDENSER
ConditionPossible CauseCorrection
Considerable vibration in
condenser.Resonance from condenser
mounting stay and body.Firmly insert a silencer between
condenser mounting stay and
body.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-11
COMPRESSION SYSTEM DIAGNOSIS
Compressor troubles are mainly following three types: gas leakage, noise and insufficient pressure.
Compressor gas leakages in most cases develop from the shaft seal. When detecting gas leakage, always use
a leak tester. If a small amount of oil seeps out from the shaft seal, there is no necessity of replacing the seal. The
shaft seal has been designed to allow a small amount of oil to leak out for lubricating purpose. Thus, the shaft seal
should be replaced only when a large amount of compressor oil is leaking out or when gas leakage is discovered
by using gas tester.
In regard to noise and insufficient pressure, repairs should be made only after diagnosing the trouble properly.
CONDITION
POSSIBLE CAUSESCORRECTION
Noise from compressorDefective bearing
Defective cylinder and / or shaftReplace.
Replace.
Noise from magnetic clutchDefective bearing
Defective clutch faceReplace.
Replace.
Insufficient coolingDefective gasketReplace.
Defective reed valveReplace.
Not rotatingLocked compressor
Seized magnetic clutch
Rotating parts seized by insufficient oil
amountReplace.
Replace.
Replace.
Oil and / or gas leakageDefective seal
Defective O-ringReplace.
Replace.
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-13
9) Check for each pressure of low side and high side if it is within
shaded range of graph.
If each gauge reading is out of specified pressure, correct de-
fective part referring to following Test Diagnosis table.
Example:
Gauges should read as follows when ambient
temperature is 30C.
Pressure on high pressure
gauge (HI):1400 ± 1750 kPa
14.0 ± 17.5 kg / cm
2
Pressure on high pressure
gauge (LO):230 ± 350 kPa
2.3 ± 3.5 kg / cm
2
NOTE:
Pressure registered on gauge varies with ambient temper-
ature. Therefore, use left graphs when determining if pres-
sures are normal or not.
10) Check inlet port temperature-to-outlet port temperature rela-
tionship using graph.
For example, if evaporator inlet port temperature is 25C
(77F) and center duct air outlet temperature is 8C (46.4F),
their crossing point is within acceptable range as shown in
graph.
11) If crossing point is out of acceptable range, diagnose trouble
referring to following Performance Diagnosis table.
YH4
GRAND
VITARA
1B-14 AIR CONDITIONING (OPTIONAL)
HIGH PRESSURE CAUGE LOW PRESSURE GAUGE THERMOMETER AT
CENTER DUCT
Insufficient
cooling of
condenser
PERFORMANCE DIAGNOSIS TABLE
TESTING RESULTSPOSSIBLE CAUSEREMEDY
Pressure high
(ªAº area of high side
graph)Refrigerant overcharged
Expansion valve frozen or clogged
Clogged refrigerant passage of high side
Condenser fan malfunction
Dirty or bent condenser fins
Compressor malfunction (Insufficient oil etc.)
Engine overheatRecharge
Check expansion valve
Clean or replace
Check condenser fan
Clean or repair
Check compressor
Check engine cooling
system
Pressure low
(ªBº area of high side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check for leakage, repair if
necessary and recharge
Check expansion valve
Check compressor
Pressure high
(ªAº area of low side
graph)Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check expansion valve
Check compressor
Pressure low
(ªBº area of low side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
narrow)
Clogged refrigerant passage (Crashed pipe)Check for leakage, repair if
necessary and recharge
Check expansion valve
Repair or replace
Outlet air temperature
at center duct is high
(Crossing point is in
area ªAº)Insufficient or excessive charge of refrigerant
Dirty or bent evaporator fins
Air leakage from cooling (heater) unit or air
duct
Malfunctioning, switchover function of damper
in cooling (heater) unit
Compressor malfunctionCheck refrigerant
pressure
Clean or repair
Repair or replace
Repair or replace
Check compressor
Outlet air temperature
at center duct is low
(Crossing point is in
area ªBº)Insufficient air volume from center duct
(Heater blower malfunction)
Compressor malfunctionCheck blower motor and
fan
Check compressor
NOTE:
If ambient temperature is within 30 ± 35C (85 ± 95F), it is possible to do using next page table for more
detail diagnosis.