Page 568 of 788
HEATER UNIT, HEATER CORE, BLOWER ASSEMBLY AND EVAPORATOR UNIT
HEATER, AIR CONDITIONER AND VENTILATION55-84
BLOWER ASSEMBLY
DISASSEMBLY AND REASSEMBLYM1551005500179
AC3054131AB
3
4
57
6
12
Disassembly steps
1. Joint duct
2. Resister
3. Outside/inside air selection damper
control motor
4. Hose5. Blower motor
6. Air filter
7. Blower caseDisassembly steps (Continued)
Page 569 of 788
Page 570 of 788
Page 571 of 788
BLOWERMOTOR, RESISTOR AND OUTSIDE/ INSIDE AIR SELECTION DAMPER CONTROL MOTOR
HEATER, AIR CONDITIONER AND VENTILATION55-87
OUTSIDE/INSIDE AIR SELECTION
DAMPER CONTROL MOTOR CHECK
CAUTION
Cut off the battery voltage when the damper is in
the inside/outside air position.
Lever position Battery
connectionLever
operation
At the inside
position•Connect
terminal 7 to
the positive
battery
terminal
•Connect
terminal 4 to
the negative
battery
terminalThe lever
moves from the
inside position
to the outside
position
At the outside
position•Connect
terminal 7 to
the positive
battery
terminal
•Connect
terminal 6 to
the negative
battery
terminalThe lever
moves from the
outside position
to the inside
position
AC100625
Inside air
Outside air
AE
Page 572 of 788
Page 573 of 788
Page 574 of 788
Page 575 of 788