Page 1954 of 4731
![INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation Proced INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation Proced](/manual-img/42/57020/w960_57020-1953.png)
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation ProcedureABS006VX
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-II changes to “COMPLETED”. (It will take approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
564, "Diagnostic Procedure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Select Service $07 with GST.
5. If 1st trip DTC is detected, go to EC-564, "
Diagnostic Procedure" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1444
1444 EVAP canister purge
volume control solenoid
valve The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve is
completely closed.
EVAP control system pressure sensor
EVAP canister purge volume control
solenoid valve
(The valve is stuck open.)
EVAP canister vent control valve
EVAP canister
Hoses
(Hoses are connected incorrectly or
clogged.)
PBIB0839E
Page 1955 of 4731
EC-562
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Wiring DiagramABS006VY
TBWM0398E
Page 1957 of 4731
![INFINITI FX35 2005 Service Manual EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SU INFINITI FX35 2005 Service Manual EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SU](/manual-img/42/57020/w960_57020-1956.png)
EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
IPDM E/R harness connector E7
20A fuse
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2006E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 1960 of 4731
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-567
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Component InspectionABS006W0
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Without CONSULT-II
Check air passage continuity of EVAP canister purge volume control
solenoid valve under the following conditions.
Removal and InstallationABS006W1
EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EM-19, "INTAKE MANIFOLD COLLECTOR" .
Condition
(PURG VOL CONT/V value) Air passage continuity
between A and B
100% Yes
0% No
PBIB0149E
Condition Air passage continuity
between A and B
12V direct current supply between
terminals 1 and 2 Ye s
No supply No
PBIB0150E
Page 1961 of 4731
![INFINITI FX35 2005 Service Manual EC-568
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
DTC P1446 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS006W2
The EVAP canister vent control INFINITI FX35 2005 Service Manual EC-568
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
DTC P1446 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS006W2
The EVAP canister vent control](/manual-img/42/57020/w960_57020-1960.png)
EC-568
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
DTC P1446 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS006W2
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows EVAP
Control System diagnosis.
CONSULT-II Reference Value in Data Monitor ModeABS006W3
Specification data are reference values.
On Board Diagnosis LogicABS006W4
PBIB1263E
PBIB1611E
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V
Ignition switch: ON OFF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1446
1446 EVAP canister vent con-
trol valve close EVAP canister vent control valve remains
closed under specified driving conditions.
EVAP canister vent control valve
EVAP control system pressure sensor
and the circuit
Blocked rubber tube to EVAP canister
vent control valve
EVAP canister is saturated with water
Page 1962 of 4731
![INFINITI FX35 2005 Service Manual DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-569
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC Confirmation ProcedureABS006W5
NOTE:
If DTC Confirmation Procedure h INFINITI FX35 2005 Service Manual DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-569
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC Confirmation ProcedureABS006W5
NOTE:
If DTC Confirmation Procedure h](/manual-img/42/57020/w960_57020-1961.png)
DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-569
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC Confirmation ProcedureABS006W5
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON and wait at least 5 seconds.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
4. Start engine and let it idle for at least 1 minute.
5. Repeat next procedures 3 times.
a. Increase the engine speed up to 3,000 to 3,500 rpm and keep it for 2 minutes and 50 seconds to 3 minutes.
Never exceed 3 minutes.
b. Fully released accelerator pedal and keep engine idle for about 5 seconds.
6. If 1st trip DTC is detected, go to EC-571, "
Diagnostic Procedure"
.
If 1st trip DTC is not detected, go to the next step.
7. Repeat next procedure 20 times.
a. Quickly increase the engine speed up to 4,000 to 4,500 rpm or more and keep it for 25 to 30 seconds.
b. Fully released accelerator pedal and keep engine idle for at least 35 seconds.
8. If 1st trip DTC is detected, go to EC-571, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF058Y
PBIB0972E
Page 1963 of 4731
EC-570
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
Wiring DiagramABS006W6
TBWH0110E
Page 1964 of 4731
![INFINITI FX35 2005 Service Manual DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-571
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each ter INFINITI FX35 2005 Service Manual DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-571
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each ter](/manual-img/42/57020/w960_57020-1963.png)
DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-571
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006W7
1. CHECK RUBBER TUBE
1. Turn ignition switch OFF.
2. Disconnect rubber tube connected to EVAP canister vent control valve.
3. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 2.
NG >> Clean rubber tube using an air blower.
2. CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-348, "
Component Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Replace EVAP canister vent control valve.
3. CHECK IF EVAP CANISTER SATURATED WITH WATER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
2. Check if water will drain from the EVAP canister.
Ye s o r N o
Ye s > > G O T O 4 .
No >> GO TO 6.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
11 7 R / Y EVAP canister vent control
valve [Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
PBIB1611E
PBIB1031E