Downloaded from www.Manualslib.com manuals search engine 73
ENGINE
73
COOLING SYSTEM SPECIFICATIONS
Engine type
Capacity
Radiator surface
Pressurisation
Opening of thermostatic regulator
Cooling fan
1st speed
2nd speed
3rd speed
Air con cut-off
Alert
Post cooling
Marking
Information
Sensor
Colour of connector
Tightening (m.daN)
Engines: ES9A - DTE17BTED4
3.0i 24S 2,7 24V
XFV UHZ
11,3 13,2
27 dm
2
1,4 bar
78°C 83°C
1 x 600 W 2 x 150W
FRIC function 97°C or aircon in operation
105°C 101°C or 17 bars in the aircon circuit
105° or 30 bars in the aircon circuit
115°C or 30 bars in the aircon circuit
118°C
6 minutes
11 6
Level of coolant Temperature of coolant Temperature, diesel injection, alert, aircon
Resistance Thermostat Thermostat
Black Blue Grey
1,7 ± 0,4
Angl-C6-page022-82-2005 4/02/05 17:19 Page 73