Page 287 of 462
Downloaded from www.Manualslib.com manuals search engine 281
ENGINE
CHECKING THE OIL PRESSURE
To be read with the Petrol and Diesel correspondence tables
XSARA PICASSO
Engine type NFV 6FZ RFN 9HZ 9HY RHY
Temperature (°C) 90°C 80°C 90°C
Pressure (bars) 3,3 1,5 1,3 2
Rpm 1000
Pressure (bars) 3
Rpm 2000
Pressure (bars) 5
Rpm 3000
Pressure (bars) 4 6,3 3,5 4
Rpm 4000 4000
Tools (Toolkit 4103-T)
2279-T.Bis X X X X X X
4103-T X X X X X X
7001-T X
4202-T X X X
1503-J X X
NOTE: The oil pressure should be checked with the engine hot, after the oil level has been checked.
XSARA PICASSO
Angl.-t2-page240-282-2005 9/01/06 10:16 Page 281
Page 366 of 462
Downloaded from www.Manualslib.com manuals search engine 360
CLUTCH
GEARBOX
TRANSMISSION
DRIVESHAFTS - GEARBOX
Tightening torques (m.daN)Gearbox oil seal mandrels
Vehicles GearboxDriveshaft Driveshaft
Engines
bearing nutRH side LH side Toolkit
C4
MA/5ET3J4 TU5JP4
XSARA TU3JP TU5JP4
C4EW10/DV6 7114-T.W 7114-T.X 7116-T
BE4/5All types
XSARA EW7/10J4B DW8
XSARA PICASSO DV6/DW10
C4ML6 DW10BTED4 9017-T.C 5701-T.A 9017-T
TU5JP4 EW10A 2 ± 0,2 32,5 ± 2,6
(-) 0338 J1 (-) 0338 H1
XSARATU5JP EW10J4
+ (-) 0338 J3 (-) 0338 H2
DW10ATED
AL4Seal extractor
RH / LH(-). 0338
XSARA PICASSO EW10J4 (-) 0338 C
(-) 0338 J1 (-) 0338 H1
+ (-) 0338 J3 (-) 0338 H2
Tightening torque (m.daN) for wheel bolts.
C4 = 9 ± 1 XSARA = 8,5 ± 0,8 XSARA PICASSO = 10 ± 1
Angl.-t2-page306-360-2005 9/01/06 10:20 Page 360
Page 434 of 462
Downloaded from www.Manualslib.com manuals search engine AIR CONDITIONING R 134.a (HFC)
Vehicle
All types
C4(except DW10BTED4)
09/04 ➔ ➔
450 ± 25SD 7C 12
DW10BTED4 SD 6 C 12
XSARAAll types 10/00 ➔ ➔
565 ± 25
135 SP 10
TU5JP + EW7
XSARAEW10J412/02 ➔ ➔
675 ± 50
SD 6 V 12
PICASSODV6TED4 01/04 ➔ ➔
625 ± 50
DW10 12/02 ➔ ➔
675 ± 50 Engines DateRefrigerant
refill (gr)Compressor
Variable
CapacityOil quantity
ccOil reference
428
AIR
CONDITIONING
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 428
Page 436 of 462
Downloaded from www.Manualslib.com manuals search engine 430
AIR
CONDITIONING
Checking the compressor oil level (continued)
2/ Slow leak.
Slow leaks do not lead to oil loss, therefore the same procedure should be followed as if there was no leak at all.
3/ Fast leak.
This type of leak causes both oil loss as well as allowing air to enter the system.
It is therefore necessary to:
- Replace the dehydrator.
- Drain as much oil as possible
(when replacing the faulty component).
Either before or during filling of the system with R 134.afluid, introduce 80 ccof NEWoil into the circuit.
When changing one of the following components, add the quantity stated:
- A drying bottle : 15 ccof compressor oil.
- A condenser or an evaporator : 20 ccof compressor oil.
- High pressure or low pressure pipework : 5 ccof compressor oil.
- A drying cartridge : 15 ccof compressor oil.
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 430
Page: