Page 153 of 462
Downloaded from www.Manualslib.com manuals search engine 147
ENGINE
SPECIAL FEATURES - TIGHTENING TORQUES (m.daN)
Accessories
34 Alternator support 2 ± 0,2
35 Alternator 4,9 ± 0,4
36 Aircon compressor 2,5 ± 0,2
37 Accessories belt tensioner roller 4,3 ± 0,4
Engine: RHR
B1BP390D
C4
Angl.-t2-page135-239-2005 9/01/06 10:13 Page 147
Page 163 of 462
Downloaded from www.Manualslib.com manuals search engine 157
ENGINE
B1EP1GQD
AUXILIARY EQUIPMENT DRIVE BELT
Engine: KFU
Véhicule with air conditioning.
Removing.
Place tool [4]at «a».
Compress the dynamic tensioner roller.
Place tool [3]at «b».
Remove the auxiliary equipment drive belt.
IMPERATIVE: Check that the dynamic tensioner roller turns freely
(without play and without tight
spots).
Refitting.
NOTE: Visually check the condition of the auxiliary equipment drive belt prior to refitting.
Place tool [4]at «a».
Compress the dynamic tensioner roller.
Remove tool [3].
Refit the auxiliary equipment drive belt.
Respect the following sequence:
- Crankshaft pinion, aircon compressor pulley, alternator pulley, dynamic tensioner roller.
Remove the tools.
Complete the refitting.
C4
Angl.-t2-page135-239-2005 9/01/06 10:14 Page 157
Page 167 of 462
![Citroen C4 2005 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 161
ENGINE
B1EP1FUD
B1EP1FVC
AUXILIARY EQUIPMENT DRIVE BELT
Engine: RFJ
Tool.
[1]«Junior» T extension: (-).1608.E
Removing.
Engage tool [1]in Citroen C4 2005 2.G Workshop Manual Downloaded from www.Manualslib.com manuals search engine 161
ENGINE
B1EP1FUD
B1EP1FVC
AUXILIARY EQUIPMENT DRIVE BELT
Engine: RFJ
Tool.
[1]«Junior» T extension: (-).1608.E
Removing.
Engage tool [1]in](/manual-img/9/4138/w960_4138-166.png)
Downloaded from www.Manualslib.com manuals search engine 161
ENGINE
B1EP1FUD
B1EP1FVC
AUXILIARY EQUIPMENT DRIVE BELT
Engine: RFJ
Tool.
[1]«Junior» T extension: (-).1608.E
Removing.
Engage tool [1]in the notch «a».
Exert on the roller (1)an effort upwards to hold it at maximum.
Remove the auxiliaries drive belt.
Carefully release the tensioner roller (1)to reach its minimum.
Remove tool[1].
IMPERATIVE: Check that the roller (1) turns freely
(without play and without tight spots).
Refitting.
If removing the auxiliaries drive belt tensioner roller, tighten the screws 2 ± 0,2 m.daN.
Engage tool [1]in the notch at «a».
Exert on the roller (1)an effort upwards to hold it at maximum.
Position the
(new)auxiliaries drive belt, in the following sequence:
- Auxiliaries drive pulley (4), aircon compressor pulley (3), tensioner roller (1)and alternator pulley (2).
IMPERATIVE: Make sure that the auxiliaries drive belt is correctly positioned in the grooves of
the various pulleys.
Release the tensioner roller (1).
Remove tool [1].
Checking the tension of the auxiliaries drive belt.
Check the tension of the auxiliaries drive belt:
- Mark «b»at the level of mark «c», new belt.
- Mark «b»at the level of mark «d», belt to be changed.
C4
Angl.-t2-page135-239-2005 9/01/06 10:14 Page 161
Page 438 of 462
Downloaded from www.Manualslib.com manuals search engine 432
AIR
CONDITIONING
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Pollen filter
XSARA
Removing-refitting.
Remove:
- The interior trim (1).
- The cover (4).
- The pollen filter (3).
Concerns vehicles equipped with aircon without temperature regulation.
Fitting of a new pollen filter necessitates the following operations:
- Engage the pollen filter upwards
(following arrow «c»).- Slide the pollen filter towards the rear (following arrow «d»).- Position the index(4)on the cover forward of the pollen filter ((4)Index on
the cover).
C5HP07JC
C5FP075D
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 432
Page 441 of 462
Downloaded from www.Manualslib.com manuals search engine 435
AIR
CONDITIONING
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]Charge station:
(according to workshop equipment)[2]TORX adaptor: TORX 70 FACOM
Removing.
Depressurise the aircon circuit, using tool [1].
Uncouple the hose (2).
Remove:
- The air filter assembly (3).
- The nuts (1).
Protect the radiator harness with strong cardboard cut to the dimensions of the radiator.
Move aside the cooling fan.
Remove:
- The screws (4).
- The brackets (5).
B1BP23FCB1BP23GC
XSARA PICASSO
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 435
Page 442 of 462

Downloaded from www.Manualslib.com manuals search engine 436
AIR
CONDITIONING
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Move aside the radiator/condenser assembly.
Remove the plug (6), using tool [2].
Support the radiator/condenser assembly thus moved aside.
Remove the filtering/drying cartridge (7), using pliers.
Refitting.
Refit the filtering/drying cartridge (7).
Clean the threads of the plug (6).
It is essntial to change the O-ring seals (8).
Lubricate the O-ring seals (8)with aircon compressor oil.
Refit:
- The plug (6), using tool [2], tighten to 1,4 ± 0,2 m.daN.
- The brackets (5).
- The screws (4).
- The cardboard from the radiator harness.
- The nuts (1).
- The air filter assembly (3).
Couple the hose (2).
Recharge the circuit (R134.a)
(according to equipment) (see corresponding
operation).
Check the operation of the air conditioning.
C5HP14NCC5HP14PCC5HP14QC
XSARA PICASSO
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 436
Page 446 of 462

Downloaded from www.Manualslib.com manuals search engine 440
AIR
CONDITIONING
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Interpretation of the measurements.
«m»:High pressure.«s»:Over-heating (SC).
«n»:High temperature.«t»:Ambient air temperature.
«p»:Under-cooling (SR).«u»:Blown air temperature.
«q»:Low pressure.«v»: Humidity.
«r»:Low temperature.«w»: Temperature T3.
Under-cooling.
The under-cooling represents the difference between the condensation temperature and the aircon
fluid temperature at the aircon condenser outlet.
The under-cooling gives the quantity of aircon fluid
(in the liquid state)in the air conditioning circuit.
Values for under-cooling (SR).
Values «p» Origins Solutions
SR < 2°CLack of aircon fluid in the aircon condenser
(should be more than 150grammes)
Add some
2°C < SR <4°CLack of aircon fluid in the aircon condenser aircon fluid
(should be around 100to 150grammes)
4°C < SR < 10°C/12°CCorrect quantity
SR > 10°C/12°CRemove some
Excess aircon fluid in the aircon condenser aircon fluid
SR > 15°C
Blown air temperature «u».
The blown air temperature should be between 2°Cand 10°C.
E5AP2FBC
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 440
Page 447 of 462

Downloaded from www.Manualslib.com manuals search engine 441
AIR
CONDITIONING
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Interpretation of the measurements.
«m»:High pressure.«s»: Over-heating (SC).
«n»:High temperature.«t»:Ambient air temperature.
«p»:Under-cooling (SR).«u»:Blown air temperature.
«q»:Low pressure.«v»:Humidity.
«r»: Low temperature.«w»: Temperature T3.
Over-heating (SC).
The over-heating represents the difference between the aircon fluid temperature at the evaporator outlet
and the evaporation temperature.
The over-heating gives the quantity of aircon fluid (in the liquid state) in the air conditioning circuit
Values for over-heating (SC).
Values «s» Origins Solutions
2° < SC < 15°CCorrect quantity
SC > 15°CLack of aircon fluid in the cooling circuitAdd some
aircon fluid
SC < 2°CExcess aircon fluid in the cooling circuitRemove some
aircon fluid
Blown air temperature «u».
The blown air temperature should be between 2°Cand 10°C.
E5AP2FBC
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 441