Page 441 of 462
Downloaded from www.Manualslib.com manuals search engine 435
AIR
CONDITIONING
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]Charge station:
(according to workshop equipment)[2]TORX adaptor: TORX 70 FACOM
Removing.
Depressurise the aircon circuit, using tool [1].
Uncouple the hose (2).
Remove:
- The air filter assembly (3).
- The nuts (1).
Protect the radiator harness with strong cardboard cut to the dimensions of the radiator.
Move aside the cooling fan.
Remove:
- The screws (4).
- The brackets (5).
B1BP23FCB1BP23GC
XSARA PICASSO
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 435
Page 442 of 462

Downloaded from www.Manualslib.com manuals search engine 436
AIR
CONDITIONING
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Move aside the radiator/condenser assembly.
Remove the plug (6), using tool [2].
Support the radiator/condenser assembly thus moved aside.
Remove the filtering/drying cartridge (7), using pliers.
Refitting.
Refit the filtering/drying cartridge (7).
Clean the threads of the plug (6).
It is essntial to change the O-ring seals (8).
Lubricate the O-ring seals (8)with aircon compressor oil.
Refit:
- The plug (6), using tool [2], tighten to 1,4 ± 0,2 m.daN.
- The brackets (5).
- The screws (4).
- The cardboard from the radiator harness.
- The nuts (1).
- The air filter assembly (3).
Couple the hose (2).
Recharge the circuit (R134.a)
(according to equipment) (see corresponding
operation).
Check the operation of the air conditioning.
C5HP14NCC5HP14PCC5HP14QC
XSARA PICASSO
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 436
Page 446 of 462

Downloaded from www.Manualslib.com manuals search engine 440
AIR
CONDITIONING
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Interpretation of the measurements.
«m»:High pressure.«s»:Over-heating (SC).
«n»:High temperature.«t»:Ambient air temperature.
«p»:Under-cooling (SR).«u»:Blown air temperature.
«q»:Low pressure.«v»: Humidity.
«r»:Low temperature.«w»: Temperature T3.
Under-cooling.
The under-cooling represents the difference between the condensation temperature and the aircon
fluid temperature at the aircon condenser outlet.
The under-cooling gives the quantity of aircon fluid
(in the liquid state)in the air conditioning circuit.
Values for under-cooling (SR).
Values «p» Origins Solutions
SR < 2°CLack of aircon fluid in the aircon condenser
(should be more than 150grammes)
Add some
2°C < SR <4°CLack of aircon fluid in the aircon condenser aircon fluid
(should be around 100to 150grammes)
4°C < SR < 10°C/12°CCorrect quantity
SR > 10°C/12°CRemove some
Excess aircon fluid in the aircon condenser aircon fluid
SR > 15°C
Blown air temperature «u».
The blown air temperature should be between 2°Cand 10°C.
E5AP2FBC
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 440
Page 447 of 462

Downloaded from www.Manualslib.com manuals search engine 441
AIR
CONDITIONING
CHECKING THE EFFICIENCY OF THE AIR CONDITIONING SYSTEM
Interpretation of the measurements.
«m»:High pressure.«s»: Over-heating (SC).
«n»:High temperature.«t»:Ambient air temperature.
«p»:Under-cooling (SR).«u»:Blown air temperature.
«q»:Low pressure.«v»:Humidity.
«r»: Low temperature.«w»: Temperature T3.
Over-heating (SC).
The over-heating represents the difference between the aircon fluid temperature at the evaporator outlet
and the evaporation temperature.
The over-heating gives the quantity of aircon fluid (in the liquid state) in the air conditioning circuit
Values for over-heating (SC).
Values «s» Origins Solutions
2° < SC < 15°CCorrect quantity
SC > 15°CLack of aircon fluid in the cooling circuitAdd some
aircon fluid
SC < 2°CExcess aircon fluid in the cooling circuitRemove some
aircon fluid
Blown air temperature «u».
The blown air temperature should be between 2°Cand 10°C.
E5AP2FBC
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 441
Page 461 of 462
Downloaded from www.Manualslib.com manuals search engine 455
AIR
CONDITIONING
(1)High pressure valve
(2)Low pressure valve
(3)Dryer
NOTE:The filtering and drying cartridge is removed from under the condenser.
(4)Pressostat
T
ightening torques (m.daN).
«a» Outlet and inlet of the aircon pressure reducer, tighten to 0,8 m.daN
«b»Outlet and inlet of the aircon compressor, tighten to 0,7 m.daN
«c»and «d»Outlet and inlet of the aircon condenser, tighten to 0,6 m.daN
XSARA PICASSO AIR CONDITIONING SYSTEM (R 134.a)
C5HP1AGP
Engine: DV6TED4
Angl.-t2-page428-456-2005 9/01/06 10:25 Page 455