HEATER AND VENTILATION 1A-9
1. LO
2. M1
3. M2
4. HI
BLOWER MOTOR RESISTOR
REMOVAL
1) Disconnect negative (±) cable (2) at battery (1).
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Open glove box (1), then remove screw (2).
4) Remove glove box.
5) Disconnect blower motor resistor (1) at coupler.
6) Remove heater blower resistor (1) by removing its fastening
screw (2).
INSPECTION
Measure each terminal-to-terminal resistance on resistor.
Resistance H-LO: Approx. 2.0
H-M1: Approx. 1.0
H-M2: Approx. 0.4
If measured resistance is incorrect, replace heater blower resistor.
INSTALLATION
1) Install heater blower resistor with screws.
2) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
Page 62 of 801
YH4
GRAND
VITARA
1A-10 HEATER AND VENTILATION
2. Screws1 2
HEATER MODE CONTROL SWITCH
REMOVAL
1) Disconnect negative (±) cable at battery.
2) If equipped with air bag system, disable air bag system.
Refer to DISABLING AIR BAG SYSTEM in Section 10B.
3) Remove meter cluster hood (1) by removing its mounting
screws (2).
4) Remove ashtray, center garnish (1) and instrument glove box
compartment.
5) Remove radio (1) (if equipped) or clock or accessory case.
6) Disconnect control cables (3) from blower motor unit (2) and
heater unit (1).
Page 63 of 801
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-11
1
1. Mode control switch coupler
7) Disconnect heater blower motor switch connector (1).
8) Remove mode control switch with heater control lever assem-
bly from the removed hole in mentioned step (5).
9) Pull off heater control lever knob.
10) Remove heater mode control switch (2) with heater control
panel (3) from heater control lever assembly (1).
11) Remove heater control panel from mode control switch.
INSPECTION
Mode Control Switch
Check if continuity exists between each pair of terminals listed be-
low when mode control button is pressed.
Mode
Mode control switch terminals
VENTF ± M
BI-LEVELF ± N
HEATF ± E
DEF / HEATF ± B
DEFF ± C
With battery voltage (+) connected to terminal ªIº and (±) to termi-
nal ªFº, press each mode control button and check if indicator
lamp (3) lights.
With battery voltage (+) connected to terminal ªAº and (±) to termi-
nal ªHº, check if illumination lamp lights.
Page 64 of 801
YH4
GRAND
VITARA
1A-12 HEATER AND VENTILATION
1. Temperature control lever
2. Fresh air control lever
1. Fresh air control cable 1. Heater unit
2. Control cable1
2
INSTALLATION
1) Install in reverse order of removal procedure.
2) Adjust cables as follows.
(1) Move control lever fully in arrow direction.
(2) Push heater lever fully in arrow direction and fix cable with
clamp in position as shown in left figure.
(3) Push blower lever fully in arrow direction and fix cable with
clamp in position as shown in left figure.
NOTE:
After installing control cables, be sure that control levers
move smoothly and stop at proper position.
3) If equipped with air bag, enable air bag system. Refer to ªENAB-
LING AIR BAG SYSTEMº in Section 10B.
HEATER MODE CONTROL ACTUATOR
REMOVAL
1) Disconnect negative (±) cable at battery.
2) If equipped with air bag system, disable air bag system.
Refer to DISABLING AIR BAG SYSTEM in Section 10B.
3) Remove column hole cover.
Page 66 of 801
YH4
GRAND
VITARA
1. Blower motor switch connector
1
1A-14 HEATER AND VENTILATION
HEATER CONTROL LEVER ASSEMBLY
REMOVAL
1) Disconnect negative (±) cable at battery.
2) If equipped with air bag system, disable air bag system.
Refer to DISABLING AIR BAG SYSTEM in Section 10B.
3) Remove mode control switch. Refer to item HEATER MODE
CONTROL SWITCH in this section.
INSPECTION
Check heater blower motor switch for each terminal-to-terminal
continuity. For the detail refer to WIRING CIRCUIT earlier in this
section.
EFLMLMHH
LOW
M1
M2
HIGH
Page 67 of 801
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-15
1. Heater unit
2. Blower unit
3. Fresh air control cable
4. Temperature control cable
5. Heater control lever assembly
HEATER CONTROL CABLES
REMOVAL
1) Remove heater control lever assembly.
Refer to HEATER CONTROL LEVER ASSEMBLY in this sec-
tion.
2) Remove control cables (2) from control lever assembly (1).
INSTALLATION
1) Install in reverse order of removal procedure.
Refer to HEATER MODE CONTROL SWITCH in this section.
2) If equipped with air bag, enable air bag system.
Refer to ENABLING AIR BAG SYSTEM in Section 10B.
Page 77 of 801

YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
Page 78 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-7
ConditionPossible CauseCorrection
Cool air does not come
out or insufficient
cooling (A / C system
normal operative)Compressor faulty
Air in A / C system
Air leaking from cooling unit or air
duct
Heater and ventilation system faulty
Blower motor faulty
Excessive compressor oil existing in
A / C systemCheck compressor.
Replace condenser dryer, and
evacuation and charging.
Repair as necessary.
Check blower unit.
Check heater control lever assembly.
Check heater assembly.
Check blower motor.
Pull out compressor oil in A / C system
circuit, and replace compressor.
Cool air does not comes
out only intermittentlyWiring connection faulty
Expansion valve faulty
Excessive moisture in A / C system
A / C controller faulty
Magnetic clutch faulty
Excessive charge of refrigerantRepair as necessary.
Check expansion valve.
Replace condenser dryer, and
evacuation and charging.
Check A / C controller.
Check magnetic clutch.
Check charge of refrigerant.
Cool air comes out only
at high speedsCondenser clogged
Insufficient charge of refrigerant
Air in A / C system
Drive belt slipping
Compressor faultyCheck condenser.
Check charge of refrigerant.
Replace condenser dryer, and
evacuation and charging.
Adjust or replace drive belt.
Check compressor.
Cool air does not comes
out only at high speedsExcessive charge of refrigerant
A / C evaporator frostedCheck charge refrigerant.
Check A / C evaporator.
Check A / C thermistor.
Insufficient velocity of
cooled airA / C evaporator clogged or frosted
Air leaking from cooling unit or air
duct
Blower motor faulty
Wiring or grounding faultyCheck A / C evaporator.
Repair as necessary.
Check blower motor.
Repair as necessary.