YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-11
1. Immobilizer diagnostic coupler
EXAMPLE : COIL ANTENNA FAILURE (CODE NO.13)
Voltmeter indicator
NORMAL (No code)
Voltmeter indicatorTIME (sec.)
TIME (sec.) CODE No. 13CODE No. 13CODE No. 13
High
Low
High
Low
1. Monitor coupler
2. Service wire
A: Diagnosis switch
terminal
B: Ground terminal
DIAGNOSTIC TROUBLE CODE (DTC) CHECK
(IMMOBILIZER CONTROL MODULE)
1) Using analog type voltmeter, connect positive probe to diagnos-
tic output terminal and negative probe to ground of immobilizer
diagnostic coupler with ignition switch turned ON.
2) Read deflection of voltmeter indicator which represents DTC as
shown in example below and write it down. For details of DTC,
refer to Immobilizer Control Module side in ªDiagnostic Trouble
Code Tableº.
If voltmeter indicator dose not deflect, go to ªDiagnostic Flow
Table Aº.
NOTE:
If abnormality or malfunction lies in two or more areas, volt-
meter indicates applicable codes three times each.
DIAGNOSTIC TROUBLE CODE (DTC) CHECK (ECM/PCM)
[Not using SUZUKI scan tool] (Vehicle equipped with
monitor coupler)
1) Using service wire, ground diagnostic switch terminal in monitor
coupler.
2) Read DTC from flashing pattern of malfunction indicator lamp as
shown in example below and write it down. For details of DTC,
refer to ECM / PCM side in ªDiagnostic Trouble Code Tableº.
If lamp remains ON, go to ªMalfunction Indicator Lamp Checkº
in Section 6.
NOTE:
If abnormality or malfunction lies in two or more areas, mal-
function indicator lamp indicates applicable codes three
times each.
And flashing of these codes is repeated as long as diagno-
sis terminal is grounded and ignition switch is held at ON
position.
YH4
GRAND
VITARA
8G-12 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
EXAMPLE: When serial data link wire is defective (Code No.83)
ON
OFFMalfunction
indicator lamp
Code No.83 Code No.83 Code No.83
Time (sec.)
1. Data link connector (DLC)
3) After completing the check, turn ignition switch OFF and discon-
nect service wire from monitor coupler.
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) After setting cartridge to Suzuki scan tool, connect it to data link
connector (DLC) located on underside of instrument panel at
driver's seat side.
Special Tool
(A): 09931-76011 (Suzuki scan tool)
(B): Mass storage cartridge
(C): 09931-76030 (16 / 12 pin DLC adapter)
3) Turn ignition switch ON.
4) Read DTC according to instructions displayed on Suzuki scan
tool and print it or write it down. Refer to Suzuki scan tool opera-
tor's manual for further details.
NOTE:
When reading DTC stored in ECM / PCM using Suzuki scan
tool, select ªECMº from the applications menu and ªSU-
ZUKI modeº from the communication mode menu dis-
played on Suzuki scan tool.
If ECM / PCM detects a trouble in both electric fuel injec-
tion system and immobilizer control system, Suzuki scan
tool indicates trouble codes of both systems using Suzu-
ki mode of ECM application.
If communication between Suzuki scan tool and ECM / PCM is
not possible, check if Suzuki scan tool is communicable by con-
necting it to ECM / PCM in another vehicle. If communication is
possible in this case, Suzuki scan tool is in good condition. Then
check data link connector and serial data line (circuit) in the ve-
hicle with which communication was not possible.
5) After completing the check, turn ignition switch OFF and discon-
nect Suzuki scan tool from data link connector (DLC).
YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-13
DIAGNOSTIC TROUBLE CODE TABLE
Immobilizer Control Module side
DIAGNOSTIC TROUBLE CODEDIAGNOSTIC AREADIAGNOSISNO.VOLTMETER INDICATIONDIAGNOSTIC AREADIAGNOSIS
±Normal (No code)This code appears when none of the
other codes are identified.
11
Transponder code
31
Trans onder code
12Immobilizer Control Module
Diagnose trouble according to
13Coil antenna or ignition key with
built-in transponderDiagnose trouble according to
ªDIAGNOSTIC FLOW TABLEº
corresponding to each code No.
21ECM/Immobilizer Control Module code
corres onding to each code No.
22Ignition switch circuit
23Serial data link wire
ECM / PCM side
DTC
(indicated on
Suzuki
scan tool)DTC
(indicated
by MIL)Malfunction Indicator lamp
(MIL) flashing patternDIAGNOSTIC AREADIAGNOSIS
NO DTC12Normal
This code appears when it is
confirmed that none of other
trouble codes is set for immo-
bilizer control system or elec-
tronic fuel injection system.
P162381ECM/Immobilizer
P162084Control Module codeDiagnose trouble according to
ªDIAGNOSTIC FLOW
P162282ECM / PCMTABLEº corresponding to
each code No.
P162183Serial data link wire
YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-15
1. Main fuse
2. Main relay
3. ECM/PCM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler) For G16 / J20 engine For H25 engine
G16 / J20 Engine
H25 Engine
TABLE B IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP DOSE NOT LIGHT AT IGNITION
SWITCH ON)
STEPACTIONYESNO
11) Turn ignition switch ON.
Do other indicator / warning lights in
combination meter come ON?Go to Step 2.ªIGº fuse blown, main fuse blown,
ignition switch malfunction,
ªB / Wº circuit between ªIGº fuse
and combination meter or poor
coupler connection at
combination meter.
21) Turn ignition switch OFF and
disconnect connectors from ECM /
PCM.
2) Check for proper connection to ECM /
PCM at terminal E61-5 for G16 / J20
engine or E61-23 for H25 engine.
3) If OK, then using service wire, ground
terminal E61-5 for G16 / J20 engine or
E61-23 for H25 engine in connector
disconnected.
Does immobilizer indicator lamp turn on
at ignition switch ON?Substitute a known-
good ECM / PCM and
recheck.Bulb burned out or ª(b)º wire
circuit open.
YH4
GRAND
VITARA
8G-16 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
1. Main fuse
2. Main relay
3. ECM / PCM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler) For G16 / J20 engine For H25 engine
G16 / J20 Engine
H25 Engine
TABLE C IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP REMAINS ON AFTER ENGINE
STARTS)
STEPACTIONYESNO
11) With ignition switch OFF, disconnect
couplers from ECM / PCM.
Does immobilizer indicator lamp turn ON
at ignition switch ON?ª(p)º wire shorted to
ground circuit.Substitute a known-good ECM /
PCM and recheck.
YH4
GRAND
VITARA
8G-28 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
1
1. Ignition key with built-in transponder 1. Data link connector (DLC)
HOW TO REGISTER IGNITION KEY
Register the ignition key with a built-in transponder in Immobilizer
Control Module by using the following procedure.
1) Prepare Suzuki scan tool (TECH 1A kit and cartridge for immobi-
lizer control system).
2) With ignition switch OFF, connect Suzuki scan tool to data link
connector (DLC) located on underside of instrument panel at
driver's seat side.
Special Tool
(A): 09931-76011 (Tech 1A)
(B): Immobilizer cartridge
(C): 09931-76030 (16 / 14-pin DLC cable)
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator's manual.
3) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
4) Number of Transponder codes for ignition key with a built-in
transponder that can be registered in Immobilizer Control Mod-
ule is limited to 4. If needed, clear all Transponder codes for igni-
tion key with a built-in transponder that have been registered in
Immobilizer Control Module by executing the ªCLR. TRANS
COD (CLEAR TP CODE)º command in the SELECT MODE
menu by using Suzuki scan tool.
NOTE:
When ªCLR. TRANS COD (CLEAR TP CODE)º command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicle not equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
5) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing ªENT. TRANS COD (ENT. TP
CODE)º command in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-29
7) If any other Transponder code for ignition key with a built-in
transponder needs to be registered, repeat above Steps 3), 5)
and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
PROCEDURE AFTER IMMOBILIZER
CONTROL MODULE REPLACEMENT
When Immobilizer Control Module was replaced, including when
replaced because rechecking by using a known-good Immobilizer
Control Module was necessary during trouble diagnosis, register
Transponder code and ECM / Immobilizer Control Module code in
Immobilizer Control Module and ECM / Immobilizer Control Module
code in ECM/PCM by performing following procedure.
1) Perform Steps 1) and 2) described in ªHow to register ignition
keyº section.
2) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
3) Using Suzuki scan tool, clear all transponder codes registered
in Immobilizer Control Module by executing ªCLR. TRANS COD
(CLEAR TP CODE)º command in SELECT MODE menu.
NOTE:
When ªCLR. TRANS COD (CLEAR TP CODE)º command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicles not
equipped with the monitor coupler) ON, it remains ON even
after execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
4) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing ªENT. TRANS COD (ENT. TP
CODE)º command in SELECT MODE menu.
5) Using Suzuki scan tool, register ECM / Immobilizer Control Mod-
ule code in both Immobilizer Control Module and ECM / PCM by
executing ªRECORD ECU (RECORD ECM / PCM / ICM)º com-
mand in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
7) If any other Transponder code for ignition key with a built-in trans-
ponder needs to be registered, repeat above Steps 2), 4) and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
YH4
GRAND
VITARA
8G-30 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
09931-76030
16 / 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)1. Storage case
2. Operator's manual
3. Tech 1A
4. DLC cable
(14 / 26 pin, 09931-76040)
5. Test lead/probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version1.5 or more
PROCEDURE AFTER ECM / PCM
REPLACEMENT
When ECM / PCM was replaced, including when replaced because
rechecking by using a known-good ECM / PCM was necessary dur-
ing trouble diagnosis, register ECM/Immobilizer Control Module
code in ECM / PCM by performing following procedure.
1) Perform Steps 1) and 2) described in ªHow to register ignition
keyº section. And then turn ignition switch ON.
2) Using TECH1, register ECM/Immobilizer Control Module code in
ECM / PCM by executing ªRECORD ECU (RECORD ECM / PCM/
ICM)º command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to TECH1
operator's manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS