EC-226
[VQ35DE]
DTC P0134, P0154 HO2S1
Revision: 2004 November 2004 FX35/FX45
DTC P0134, P0154 HO2S1PFP:22690
Component DescriptionABS006O8
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS006O9
Specification data are reference values.
On Board Diagnosis LogicABS006OA
Under the condition in which the heated oxygen sensor 1 signal is
not input, the ECM circuits will read a continuous approximately
0.3V. Therefore, for this diagnosis, the time that output voltage is
within 200 to 400 mV range is monitored, and the diagnosis checks
that this time is not inordinately long.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times
during 10 seconds.
SEF237U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0134
0134
(Bank 1)Heated oxygen sensor
1 circuit no activity
detectedThe voltage from the sensor is constantly
approx. 0.3V.
Harness or connectors
(The sensor circuit is open or shorted)
Heated oxygen sensor 1 P0154
0154
(Bank 2)
EC-234
[VQ35DE]
DTC P0134, P0154 HO2S1
Revision: 2004 November 2004 FX35/FX45
4. CHECK HEATED OXYGEN SENSOR 1
Refer to EC-234, "
Component Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Replace malfunctioning heated oxygen sensor 1.
5. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionABS006OF
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)/(B2)” and “HO2S1 MNTR (B1)/(B2)”.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode
changes from “RICH” to “LEAN” to “RICH” 5 times in 10 sec-
onds.
5 times (cycles) are counted as shown at right.
“HO2S1 (B1)/(B2)” voltage goes above 0.6V at least once.
“HO2S1 (B1)/(B2)” voltage goes below 0.3V at least once.
“HO2S1 (B1)/(B2)” voltage never exceeds 1.0V.
SEF646Y
SEF647Y
SEF648Y
DTC P0139, P0159 HO2S2
EC-247
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
6. Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
A change of voltage should be more than 0.06V for 1 sec-
ond during this procedure.
If the voltage can be confirmed in step 6, step 7 is not nec-
essary.
7. Keep vehicle at idling for 10 minutes, then check the voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in D
position with “OD” OFF.
A change of voltage should be more than 0.06V for 1 sec-
ond during this procedure.
8. If NG, go to EC-251, "
Diagnostic Procedure" .
PBIB1607E
EC-322
[VQ35DE]
DTC P0441 EVAP CONTROL SYSTEM
Revision: 2004 November 2004 FX35/FX45
Always perform test at a temperature of 5°C (41°F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 70 seconds.
4. Select “PURG FLOW P0441” of “EVAPORATIVE SYSTEM” in “DTC CONFIRMATION” mode with CON-
SULT-II.
5. Touch “START”.
If “COMPLETED” is displayed, go to step 7.
6. When the following conditions are met, “TESTING” will be displayed on the CONSULT-II screen. Maintain
the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take at least 35 seconds.)
If “TESTING” is not changed for a long time, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
323, "Diagnostic Procedure" .
Overall Function CheckABS006QO
Use this procedure to check the overall monitoring function of the EVAP control system purge flow monitoring.
During this check, a 1st trip DTC might not be confirmed.
WITH GST
1. Lift up drive wheels.
2. Start engine (TCS switch or VDC switch OFF) and warm it up to normal operating temperature.
3. Turn ignition switch OFF, wait at least 10 seconds.
4. Start engine and wait at least 70 seconds.
5. Set voltmeter probes to ECM terminals 32 (EVAP control system
pressure sensor signal) and ground.
6. Check EVAP control system pressure sensor value at idle speed
and note it.
7. Establish and maintain the following conditions for at least 1
minute.
Selector lever Suitable position
Vehicle speed 32 - 120 km/h (20 - 75 MPH)
ENG SPEED 500 - 3,000 rpm
B/FUEL SCHDL 1.3 - 9.0 msec
Engine coolant temperature 70 - 100°C (158 - 212°F)
PBIB0826E
Air conditioner switch ON
Headlamp switch ON
Rear window defogger switch ON
Engine speed Approx. 3,000 rpm
Gear position Any position other than P, N or R
PBIB1109E
DTC P1143, P1163 HO2S1
EC-433
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P1143, P1163 HO2S1PFP:22690
Component DescriptionABS006TY
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS006TZ
Specification data are reference values.
On Board Diagnosis LogicABS006U0
To judge the malfunction, the output from the heated oxygen sensor
1 is monitored to determine whether the rich output is sufficiently
high and whether the lean output is sufficiently low. When both the
outputs are shifting to the lean side, the malfunction will be detected.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times
during 10 seconds.
SEF300U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1143
11 4 3
(Bank 1)
Heated oxygen sensor
1 lean shift monitoringThe maximum and minimum voltage from the
sensor are not reached to the specified volt-
ages.
Heated oxygen sensor 1
Heated oxygen sensor 1 heater
Fuel pressure
Injector
Intake air leaks P1163
11 6 3
(Bank 2)
DTC P1143, P1163 HO2S1
EC-437
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Component InspectionABS006U4
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)/(B2)” and “HO2S1 MNTR (B1)/(B2)”.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode
changes from “RICH” to “LEAN” to “RICH” 5 times in 10 sec-
onds.
5 times (cycles) are counted as shown at right.
“HO2S1 (B1)/(B2)” voltage goes above 0.6V at least once.
“HO2S1 (B1)/(B2)” voltage goes below 0.3V at least once.
“HO2S1 (B1)/(B2)” voltage never exceeds 1.0V.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] or 16 [HO2S1 (B2) signal] and
ground.
SEF646Y
SEF647Y
SEF648Y
DTC P1144, P1164 HO2S1
EC-439
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
DTC P1144, P1164 HO2S1PFP:22690
Component DescriptionABS006U6
The heated oxygen sensor 1 is placed into the exhaust manifold. It
detects the amount of oxygen in the exhaust gas compared to the
outside air. The heated oxygen sensor 1 has a closed-end tube
made of ceramic zirconia. The zirconia generates voltage from
approximately 1V in richer conditions to 0V in leaner conditions. The
heated oxygen sensor 1 signal is sent to the ECM. The ECM adjusts
the injection pulse duration to achieve the ideal air-fuel ratio. The
ideal air-fuel ratio occurs near the radical change from 1 to 0V.
CONSULT-II Reference Value in Data Monitor ModeABS006U7
Specification data are reference values.
On Board Diagnosis LogicABS006U8
To judge the malfunction, the output from the heated oxygen sensor
1 is monitored to determine whether the rich output is sufficiently
high and lean output is sufficiently low. When both the outputs are
shifting to the rich side, the malfunction will be detected.
SEF463R
SEF288D
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 (B1)
HO2S1 (B2)
Engine: After warming up Maintaining engine speed at 2,000 rpm0 - 0.3V ←→ Approx. 0.6 -
1.0V
HO2S1 MNTR (B1)
HO2S1 MNTR (B2)LEAN ←→ RICH
Changes more than 5 times
during 10 seconds.
SEF299U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1144
11 4 4
(Bank 1)
Heated oxygen sensor
1 rich shift monitoringThe maximum and minimum voltages from the
sensor are beyond the specified voltages.
Heated oxygen sensor 1
Heated oxygen sensor 1 heater
Fuel pressure
Injector P1164
11 6 4
(Bank 2)
EC-444
[VQ35DE]
DTC P1144, P1164 HO2S1
Revision: 2004 November 2004 FX35/FX45
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode
changes from “RICH” to “LEAN” to “RICH” 5 times in 10 sec-
onds.
5 times (cycles) are counted as shown at right.
“HO2S1 (B1)/(B2)” voltage goes above 0.6V at least once.
“HO2S1 (B1)/(B2)” voltage goes below 0.3V at least once.
“HO2S1 (B1)/(B2)” voltage never exceeds 1.0V.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 [HO2S1 (B1) signal] or 16 [HO2S1 (B2) signal] and
ground.
3. Check the following with engine speed held at 2,000 rpm con-
stant under no load.
The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V
more than 5 times within 10 seconds.
The maximum voltage is over 0.6V at least one time.
The minimum voltage is below 0.3V at least one time.
The voltage never exceeds 1.0V.
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 - 1.0V
CAUTION:
Discard any heated oxygen sensor which has been
dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor;
use a new one.
SEF646Y
SEF647Y
SEF648Y
PBIB1107E