Downloaded from www.Manualslib.com manuals search engine 274
INJECTION
PARTICLE FILTER SAFETY AND CLEANLINESS REQUIREMENTS
Operations on the fuel additive circuit.
IMPERATIVE: For all operations on the additive circuit, wear protective goggles and gloves that are resistant to hydrocarbons.
The work area must be ventilated.
In the event of any significant dispersion of additive:
Wear a breathing mask for filtering the particles.
Recover as much of the product as possible.
Place the product thus recovered in an appropriately labelled container. Wash the soiled area with copious amounts of water.
Dispose of materials and solid residues in an authorised recovery point.
IMPERATIVE:The filling kit should be recycled following a repair. All «Eolys» additive containers that have been opened should be
disposed of.
Cleanliness rules.
ESSENTIAL: The operator should wear clean overalls.
Before working on the injection circuit, it may be necessary to clean the unions of the following sensitive components(see corresponding operations).
Fuel filter.
Fuel high pressure pump.
Fuel high pressure regulator.
Fuel high pressure common injection rail. Fuel high pressure piping. Diesel injector carriers.
IMPERATIVE: After dismantling, immediately blank the unions of the sensitive components with plugs, to prevent any ingress of impurities.
ALL TYPES
Downloaded from www.Manualslib.com manuals search engine 278
INJECTION
SPECIAL FEATURES: PARTICLE FILTER / CHECKING THE ADDITIVE PUMP
Sealing of the additive injector.
Couple tool [1] to the tube (1).
Action the manual pump [1].
WARNING:The additive injector should open at a pressure of 100 ± 20 Bars.
Action the manual pump in vacuum
[1]at 800 m.bars.
WARNING:The downstream pressure should not fall rapidly.
NOTE:Replace the fuel tank if the injector is defective.
Couple the tube
(1).
Operate the actuator test «Filling the tube: additive pump – additive injector», with the aid ofLEXIAor PROXIA.
Check the additive level.
The checking of the additive level is done with reference to the gradations «a»marked on the additive
reservoir.
The top graduation indicates maximum filling
(3 Litres).
The difference between the two gradations equates to 0,25 Litres.
XSARA PICASSO
B1HP1UUC
B1KP019C