Downloaded from www.Manualslib.com manuals search engine 489
ELECTRICAL
SYSTEM
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Pollen filter
Note:
The pollen filter is located in the engine compartment on the RH side.
Removing.
Remove:
The three screws (1).
The plastic cover (2).
Tilt the flap
(3).
Remove the pollen filter
(4).
Refitting.
Proceed in reverse order.
C4AP169CC4AP16ACC4AP16BC
C3 C3 PLURIEL
Downloaded from www.Manualslib.com manuals search engine 490
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]
Charge station :(according to workshop equipment)[2]TORX adaptor: TORX 70 FACOM
[3]Inertia extractor:1671 T Tool kit 4114 T
[4]Endpiece Ø 20 : 1671 T.D20
[5]Set of plugs: ( ).0188.T
[6]Circlip pliers: FACOM
Removing.
Depressurise the aircon circuit, using tool [1].
Remove the grille.At
«a», remove the pin and the plastic cover.
Unclip the condenser at «b»and «c», using a screwdriver.
Tilt the condenser towards the front.
Lift and release the condenser.Clean the area around the cap
(3).
Remove the plastic cap (3), using tool [2].
Remove the safety circlip (4), using tool [6].
Position the tool [3]and[4]in the aperture of the cartridge (5).
Extract the cartridge from the reservoir (6), using tool [3]and [4].
Block the reservoir (6), using tool [5].
C4AP163CC4AP164CC4AP166CC4AP165C
C2 C3 C3 PLURIEL
Downloaded from www.Manualslib.com manuals search engine 506
ELECTRICAL
SYSTEM
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP1A8D
Key.
T/P
= Average temperature(°C ) at the air vents/
high pressure(Bars).
P
= Low pressure(Bars).
TE = Exterior temperature(C°).
HP = Pressure at compressor outlet (Bars).
BP = Pressure at compressor inlet(Bars).
TA = Average temperature(°C) of air blown from
the central vents.
C3 C3 PLURIEL BV MECANIQUE 8HX 8HW