Page 104 of 801

YH4
GRAND
VITARA
2. Bolt
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-33
A / C CONDENSER ASSEMBLY
INSPECTION
Check
a) condenser fins for blockage
b) condenser fittings for leakage
c) condenser fins for damage
Clogged condenser fins should be washed with water, and should
be dried with compressed air.
CAUTION:
Be careful not to damage condenser fins. If condenser fin is
bent, straighten it by using a screwdriver or pair of pliers. If
any leakage is found from fitting or tube, repair or replace
condenser.
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
3) Remove front bumper assembly and remove lower stay (1) if
equipped (Refer to Section 9 ªBODY SERVICEº).
4) Disconnect compressor discharge hose (1) from condenser in-
let fittings.
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust do not enter
condenser.
Page 108 of 801
YH4
GRAND
VITARA
1
For CAMI production vehicle
For IWATA production vehicle
1
AIR CONDITIONING (OPTIONAL) 1B-37
AIR FILTER ELEMENT
REMOVAL
1) Disconnect negative (±) cable at battery.
2) For vehicle with air bag system, disable air bag system. Refer
to ªDISABLING AIR BAG SYSTEMº in Section 10B.
3) Pull down glove box (1) by pushing the shown part (a).
4) Remove filter cover (1).
5) Pull out filter element (1). Pull out upper filter first then the lower
one.
Page 110 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-39
COOLING UNIT (EVAPORATOR)
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Disable air bag system. Refer to ªDisabling Air Bag Systemº in
Section 10B.
3) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
4) For G16 and J20 engine
Disconnect suction pipe (1), and liquid pipe (2) from evaporator
(cooling unit).
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust may not enter
cooling unit.
5) Remove blower motor unit. Refer to Section 1A ªHEATER AND
VENTILATIONº.
6) Disconnect thermistor wire coupler.
7) Remove cooling unit (evaporator).
DISASSEMBLY (FOR CAMI PRODUCTION VEHICLE)
1) Remove filter (2) from cooling unit (3) assembly by removing fil-
ter cover (1).
2) Remove screws (1) to separate evaporator upper and lower
cases from each other.
Page 111 of 801
YH4
GRAND
VITARA
1
1B-40 AIR CONDITIONING (OPTIONAL)
3) Remove upper case (1) and remove evaporator (2) from lower
case (3).
4) Remove following components from evaporator.
Expansion valve (5)
Thermistor (evaporator temperature sensor) (4)
DISASSEMBLY (FOR IWATA PRODUCTION VEHICLE)
1) Remove filter (2) from cooling unit (3) assembly by removing fil-
ter cover (1).
2) Detach clamps (1) to separate evaporator upper and lower
cases from each other.
3) Remove upper case (1) and remove evaporator (2) from lower
case (3).
4) Remove following components from evaporator.
Expansion valve (5)
Thermistor (evaporator temperature sensor) (4)
Page 113 of 801
YH4
GRAND
VITARA
3. Pipe clamp
1B-42 AIR CONDITIONING (OPTIONAL)
EXPANSION VALVE
INSPECTION
Refer to ªTroubleshooting Procedure Using Manifold Gauge Setº in
this section.
REMOVAL
1) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment. The
amount of compressor oil removed must be measured and the
same amount added to the system.
2) Remove front grill.
3) Disconnect suction pipe (1), and liquid pipe (2) from evaporator
(Cooling unit).
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust may not enter
cooling unit.
4) Disconnect suction pipe, and liquid pipe from suction hose (1)
and condenser outlet pipe (2).
5) Remove pipe clamp then remove suction pipe and liquid pipe.
6) Remove expansion valve (1).
INSTALLATION
1) Reverse removal sequence to install expansion valve.
2) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.
Page 115 of 801
YH4
GRAND
VITARA
1B-44 AIR CONDITIONING (OPTIONAL)
REFRIGERANT PIPES AND HOSES
INSPECTION
1) Use a leak tester to check hoses and pipes for any gas leakage.
2) Check each hose or pipe clamp for tightness.
Retighten or replace loose clamp as required, if any.
REMOVAL
1) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount must be added to the system when reinstal-
ling.
2) Replace defective hose or pipe.
CAUTION:
As soon as the above hose or pipe is disconnected, cap
its opened fitting to prevent moisture and dust from en-
tering.
INSTALLATION
1) Reverse removal procedure to install refrigerant line.
2) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.
INSPECTION OF IDLE SPEED WITH A / C ON
For G16 and J20 engines model, refer to Section 6E1.
For H25 engine model, refer to Section 6E2.
Page 121 of 801
YH4
GRAND
VITARA
1B-50 AIR CONDITIONING (OPTIONAL)
REMOVAL
1) Run engine at idle with A / C ON for 10 minutes.
2) Disconnect negative (±) cable at battery.
3) Recover refrigerant from refrigeration system using recovery
and recycling equipment.
NOTE:
The amount of compressor oil at removed must be mea-
sured and the same amount must be poured when installing
the compressor.
4) Disconnect thermal protector lead wire.
5) Disconnect suction and discharge hoses from compressor as-
sembly.
NOTE:
Cap open fitting immediately to keep moisture out of sys-
tem.
6)For G16 engine:
Remove compressor drive belt by loosening compressor as-
sembly mounting bolts.
For J20 engine:
Remove generator belt. Refer to Section 6H.
For H25 engine:
Remove compressor drive belt by loosening tension pulley bolt.
7) Remove compressor with magnet clutch assembly from its
mount.
8) If compressor assembly is replaced. Drain oil from compressor
assembly, and measure its amount.
Page 128 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-57
3) Using special tool (B), remove clutch plate (1).
Special Tool
(B): 09991-06030
4) Disconnect clutch coil lead wire from compressor thermal switch
led wire.
5) Remove felt ring (if equipped) and shims from shaft.
6) Using special tool (C), remove circlip.
Special Tool
(C): 09900-06107
7) Remove clutch coil lead wire clamp screw.
8) Remove clutch pulley with puller (1) from compressor (2).
NOTE:
Be careful not to damage pulley when tapping magnet
clutch.
9) Remove clutch coil.
INSTALLATION
1) Install clutch coil (2).
Protrusion on under side of clutch coil must match hole in com-
pressor (3) to prevent movement ant correctly locate lead wire.
2) Using special tool (C), install snap ring (1) as shown.
Special Tool
(C): 09990-06107
3) Clamp covering portion of lead wire.