YH4
GRAND
VITARA
5E1-26 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
1. ABS hydraulic unit/
control module assembly
2. ABS hydraulic unit/
control module
connector of harness
1. ABS hydraulic
unit / control
module connector
DTC 41 (DTC C1041 / C1042) ± RIGHT-FRONT SOLENOID CIRCUIT
DTC 45 (DTC C1045 / C1046) ± LEFT-FRONT SOLENOID CIRCUIT
DTC 56 (DTC C1055 / C1056) ± REAR SOLENOID CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage of the terminal of the solenoid circuit constantly with the ignition
switch turned ON. It sets this DTC when the terminal voltage does not become low / high for the ON / OFF command
to the solenoid or the voltage difference between solenoid circuit terminals exceeds the specified value with the
solenoid turned OFF.
INSPECTION
STEPACTIONYESNO
11) Check solenoid referring to item
ªABS HYDRAULIC UNIT OPERATION CHECKº
in this section.
Is it in good condition?Check terminals ªA11º
and ªA27º connection.
If connections OK,
substitute a known-
good ABS hydraulic
unit / control module
assembly and
recheck.Go to step 2.
21) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check for proper connection to ABS hydraulic
unit / control module connector at terminal ªA11º.
4) If OK, then measure voltage between terminal
ªA11º of module connector and body ground.
Is it 10 ± 14 V?Substitute a known-
good ABS hydraulic
unit / control module
assembly and
recheck.ªW / Blº circuit open.
Fig. 1
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-27
1. ABS hydraulic unit/
control module assembly
2. ABS hydraulic unit/
control module
connector
1. ABS hydraulic
unit / control
module connector
DTC 57 (DTC C1057) ± SOLENOID AND PUMP MOTOR POWER SOURCE
CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage at terminal ( ªA11º and ªA27º) of the fail-safe and pump motor relays
circuit constantly with the ignition switch turned ON. When all solenoid circuit voltages are below the specified value
or the voltage at the terminal ªA27º became below the specified value while the pump motor is operating, this DTC
will be set. As soon as the voltage rises to the specified level, the set DTC will be cleared.
INSPECTION
STEPACTIONYESNO
1Check battery voltage. Is it about 11 V or higher?Go to step 2.Check charging
system referring
to ªCHARGING
SYSTEMº section.
2Check ABS main fuse and connection. Is it in good
condition?Go to step 3.Repair and / or
replace fuse.
31) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check proper connection to ABS hydraulic unit /
control module connector at terminal ªA27º.
4) If OK, then measure voltage between connector
terminal ªA27º and body ground.
Is it 10 ± 14 V?Substitute a
known-good
ABS hydraulic
unit / control
module assembly
and recheck.ªW / Blº circuit open.
Fig. 1
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-29
1. Ignition switch
2. ABS hydraulic unit/
control module assembly
3. ABS hydraulic unit/
control module connector
of harness 2
1. ABS hydraulic
unit / control
module connector
DTC 63 (DTC C1063) ± ABS FAIL-SAFE RELAY CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage at the terminal of the solenoid circuit constantly with the ignition
switch turned ON. Also, immediately after the ignition switch is turned ªONº, perform an initial check as follows.
Switch the fail-safe relay in the order of ON OFF ON and check if the voltage at 6 solenoid circuit terminals
changes to High Low High. If anything faulty is found in the initial check and when the voltage at all solenoid
circuit terminals is low with the ignition switch turned ON and ABS not operated, this DTC will be set.
INSPECTION
STEPACTIONYESNO
1Check battery voltage. Is it about 11 V or higher?Go to step 2.Check charging
system referring
to ªCHARGING
SYSTEMº section.
2Check ABS main fuse and connection. Is it in good
condition?Go to step 3.Repair and / or
replace fuse.
31) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check proper connection to ABS hydraulic unit /
control module at terminal ªA11º.
4) If OK, then measure voltage between connector
terminal ªA11º, and body ground.
Is it 10 ± 14 V?Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.ªW / Blº circuit open
or short to ground.
Fig. 1
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-31
1. Diagnosis
connector
(6 pins connector)
2. Diag. switch
terminal
3. Ground
4. Service wire
Brake
pedal
Ignition
sw.
Motor
Solenoid
Rear3.0 sec.
3.0
ON-VEHICLE SERVICE
PRECAUTION
When connector are connected to ABS hydraulic unit / control mod-
ule assembly, do not disconnect connectors of sensors and turn
ignition switch ON. Then DTC will be set in ABS control module.
ABS HYDRAULIC UNIT OPERATION CHECK
1) Check that basic brake system other than ABS is in good condi-
tion.
2) Check that battery voltage is 11V or higher.
3) With ªABSº warning lamp, check that no abnormality is de-
tected in ABS. Refer to ªDIAGNOSTIC TROUBLE CODE
(DTC) CHECKº in this section.
4) Lift up vehicle.
5) Set transmission to neutral and release parking brake.
6) Turn each wheel gradually by hand to check if brake dragging
occurs. If it does, correct.
7) With diag. switch terminal of diagnosis connector connected to
ground by using service wire, turn ignition switch ON and check
if ªABSº warning lamp indicates DTC 12.
8) Turn ignition switch OFF.
9) Perform following checks with help of another person.
Brake pedal should be depressed and then ignition switch
turned ON by one person and wheel should be turned by
another person's hand. At this time, check that:
Operation sound of solenoid is heard and wheel turns only
about 0.5 sec. (Brake force is depressurized).
Operation sound of pump motor is heard and pulsation is felt
at brake pedal.
10) If all 4-wheels cannot be checked during one ignition cycle
(OFF ON), repeat Steps 8) and 9) till all 4 wheels are
checked.
If a faulty condition is found in Steps 9) and 10), replace hydrau-
lic unit / control module assembly.
11) Turn ignition switch OFF and remove service wire from diagno-
sis connector.
YH4
GRAND
VITARA
7B1
AUTOMATIC TRANSMISSION (4 A / T) 7B1-1
GENERAL DESCRIPTION7B1- 3 . . . . . . . . . . . . . .
CLUTCH / BRAKE FUNCTIONS 7B1- 5. . . . . . . . .
TABLE OF COMPONENT OPERATION 7B1- 6. . .
ELECTRONIC SHIFT CONTROL
SYSTEM 7B1- 7. . . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOMATIC TRANSMISSION
DIAGNOSIS7B1-17 . . . . . . . . . . . . . . . . . . . . . . . . . .
PRECAUTION IN DIAGNOSING
TROUBLE 7B1-20. . . . . . . . . . . . . . . . . . . . . . . . . .
AUTOMATIC TRANSMISSION
DIAGNOSTIC FLOW TABLE 7B1-21. . . . . . . . . .
Customer Problem Inspection Form 7B1-23. . .
Malfunction Indicator lamp (MIL)
Check 7B1-24. . . . . . . . . . . . . . . . . . . . . . . . . . .
ªO / D OFFº Lamp Check 7B1-24. . . . . . . . . . . . .
ªPOWERº Lamp Check 7B1-24. . . . . . . . . . . . . .
Diagnostic Trouble Code (DTC)
Check 7B1-24. . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic Trouble Code (DTC)
Clearance 7B1-24. . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic Trouble Code (DTC) Table7B1-24 . . .
Fail-Safe Table 7B1-25. . . . . . . . . . . . . . . . . . . . .
Visual Inspection 7B1-26. . . . . . . . . . . . . . . . . . .
A / T Basic Check 7B1-27. . . . . . . . . . . . . . . . . . .
Trouble Diagnosis Table 1 7B1-28. . . . . . . . . . .
Trouble Diagnosis Table 2 7B1-28. . . . . . . . . . . Trouble Diagnosis Table 3 7B1-29. . . . . . . . . . .
Scan Tool Data 7B1-30. . . . . . . . . . . . . . . . . . . . .
Inspection of PCM and Its Circuit 7B1-30. . . . .
Wire Harness and Connectors 7B1-30. . . . . . . .
Diagnostic Flow Table A-1 7B1-31. . . . . . . . . . .
Diagnostic Flow Table A-2 7B1-33. . . . . . . . . . .
Table B-1 ªO / D OFFº Light Circuit
Check 7B1-35. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-2 ªO / D OFFº Light Circuit
Check 7B1-36. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-3 ªPOWERº Light Circuit
Check 7B1-37. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table B-4 ªPOWERº Light Circuit
Check 7B1-38. . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC P0705 Transmission Range
Sensor (Switch) Circuit Malfunction 7B1-39. .
DTC P0715 Input / Turbine Speed
Sensor Circuit Malfunction 7B1-42. . . . . . . . . .
DTC P0720 Output Speed Sensor
Circuit Malfunction 7B1-44. . . . . . . . . . . . . . . . .
DTC P0741 TCC Solenoid Valve
Performance or Stuck Off 7B1-46. . . . . . . . . . .
DTC P0743 TCC Solenoid Electrical 7B1-47. .
DTC P0751 Shift Solenoid Valve-A (#1)
Performance or Stuck Off 7B1-49. . . . . . . . . . .
DTC P0756 Shift Solenoid Valve-B (#2)
Performance or Stuck Off 7B1-49. . . . . . . . . . .
SECTION 7B1
AUTOMATIC TRANSMISSION
(4 A/T)
WARNING:
For vehicles equipped with Supplemental Restraint (Air Bag) System:
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either of these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
CONTENTS
YH4
GRAND
VITARA
7B1-2 AUTOMATIC TRANSMISSION (4 A / T)
DTC P0753 Shift Solenoid-A (#1)
Electrical 7B1-50. . . . . . . . . . . . . . . . . . . . . . . . .
DTC P0758 Shift Solenoid-B (#2)
Electrical 7B1-50. . . . . . . . . . . . . . . . . . . . . . . . .
DTC P1875 4WD Low Switch Circuit
Malfunction 7B1-52. . . . . . . . . . . . . . . . . . . . . . .
Line Pressure Test 7B1-54. . . . . . . . . . . . . . . . . .
Stall Test 7B1-55. . . . . . . . . . . . . . . . . . . . . . . . . .
Road Test 7B1-56. . . . . . . . . . . . . . . . . . . . . . . . .
Manual Road Test 7B1-57. . . . . . . . . . . . . . . . . .
Time Lag Test 7B1-57. . . . . . . . . . . . . . . . . . . . . .
Engine Brake Test 7B1-58. . . . . . . . . . . . . . . . . .
ªPº Range Test 7B1-58. . . . . . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE7B1-59 . . . . . . . . . . . . . . . .
MAINTENANCE SERVICE 7B1-59. . . . . . . . . . . .
Fluid Level 7B1-59. . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Change 7B1-60. . . . . . . . . . . . . . . . . . . . . .
Oil Cooler Hoses 7B1-61. . . . . . . . . . . . . . . . . . .
A / T THROTTLE CABLE 7B1-61. . . . . . . . . . . . . . .
MANUAL SELECTOR ASSEMBLY 7B1-62. . . . .
SELECT CABLE 7B1-63. . . . . . . . . . . . . . . . . . . . . TRANSMISSION RANGE SWITCH 7B1-64. . . . .
A/T OUTPUT SPEED SENSOR 7B1-64. . . . . . . .
O / D CUT SWITCH 7B1-64. . . . . . . . . . . . . . . . . . .
SOLENOID VALVES 7B1-64. . . . . . . . . . . . . . . . . .
THROTTLE POSITION SENSOR 7B1-66. . . . . . .
POWER / NORMAL CHANGE SWITCH 7B1-66. .
OIL COOLER PIPES 7B1-67. . . . . . . . . . . . . . . . . .
BRAKE INTERLOCK SYSTEM 7B1-68. . . . . . . . .
Shift Lock Solenoid Control 7B1-68. . . . . . . . . .
Shift Lock Solenoid Control Operations 7B1-68
Shift Lock (Solenoid) Manual Release 7B1-69.
System Inspection 7B1-69. . . . . . . . . . . . . . . . . .
KEY INTERLOCK CABLE 7B1-71. . . . . . . . . . . . .
DISMOUNTING OF TRANSMISSION
(WITH TRANSFER IF EQUIPPED) 7B1-74. . . .
REMOUNTING 7B1-77. . . . . . . . . . . . . . . . . . . . . . .
UNIT REPAIR7B1-78 . . . . . . . . . . . . . . . . . . . . . . . . .
TIGHTENING TORQUE
SPECIFICATIONS7B1-78 . . . . . . . . . . . . . . . . . . . .
REQUIRED SERVICE MATERIALS7B1-79 . . . . . .
SPECIAL TOOLS7B1-79 . . . . . . . . . . . . . . . . . . . . . .
YH4
GRAND
VITARA
7B1-6 AUTOMATIC TRANSMISSION (4 A / T)
Element
Shift
position
TABLE OF COMPONENT OPERATION
SolenoidSolenoidO/DForwardDirect clutchO/DSecondSecondReverse brakeO/DOne-wayOne-wayvalve
No. 1±Avalve
No. 1±BO/DclutchForwardclutchInner
pistonOuter
pistonO/Dbrakecoast
brakeSecondbrakeInner
pistonOuter
pistonone-way
clutchyclutch
No. 1yclutch
No. 2
PX±±±±±±±±±±
RX±±±±±±
NX±±±±±±±±±±
1st gearX±±±±±±±±
D2nd gear±±±±±±±D3rd gearX±±±±±±±
O/DXX±±±±±±±±
1st gearX±±±±±±±±
22nd gear±±±±±±±2
3rd gear
(Fail safe)X±±±±±±±
1st gearX±±±±±±±
L2nd gear
(Fail safe)±±±±±±±
: ON, X: OFF
YH4
GRAND
VITARA
Engine
Vehicle speed
sensor
Throttle position
sensor
ECT sensor
Cruise control
module
(if equipped)Torque converter Planetary gear
Final gear
reduction unit
Oil pump
Shift and TCC
solenoid valvesClutch and brake
Control valve
ªO / D OFFº lamp
ªPOWERº lamp
MILTransmission range
switch
O / D cut switch
P / N change switch
Transfer 4L switch
(if equipped)
CMP sensor Powertrain (engine) control module
Power transmission
Fluid pressure circuit
Electric signalInput speed sensor Brake pedal switch
Output speed sensor
AUTOMATIC TRANSMISSION (4 A / T) 7B1-7
ELECTRONIC SHIFT CONTROL SYSTEM
The gear ratio change in ªDº or ª2º range and torque converter clutch operation are controlled by Powertrain (En-
gine) Control Module.