1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.
Page 84 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-13
9) Check for each pressure of low side and high side if it is within
shaded range of graph.
If each gauge reading is out of specified pressure, correct de-
fective part referring to following Test Diagnosis table.
Example:
Gauges should read as follows when ambient
temperature is 30C.
Pressure on high pressure
gauge (HI):1400 ± 1750 kPa
14.0 ± 17.5 kg / cm
2
Pressure on high pressure
gauge (LO):230 ± 350 kPa
2.3 ± 3.5 kg / cm
2
NOTE:
Pressure registered on gauge varies with ambient temper-
ature. Therefore, use left graphs when determining if pres-
sures are normal or not.
10) Check inlet port temperature-to-outlet port temperature rela-
tionship using graph.
For example, if evaporator inlet port temperature is 25C
(77F) and center duct air outlet temperature is 8C (46.4F),
their crossing point is within acceptable range as shown in
graph.
11) If crossing point is out of acceptable range, diagnose trouble
referring to following Performance Diagnosis table.
Page 85 of 801

YH4
GRAND
VITARA
1B-14 AIR CONDITIONING (OPTIONAL)
HIGH PRESSURE CAUGE LOW PRESSURE GAUGE THERMOMETER AT
CENTER DUCT
Insufficient
cooling of
condenser
PERFORMANCE DIAGNOSIS TABLE
TESTING RESULTSPOSSIBLE CAUSEREMEDY
Pressure high
(ªAº area of high side
graph)Refrigerant overcharged
Expansion valve frozen or clogged
Clogged refrigerant passage of high side
Condenser fan malfunction
Dirty or bent condenser fins
Compressor malfunction (Insufficient oil etc.)
Engine overheatRecharge
Check expansion valve
Clean or replace
Check condenser fan
Clean or repair
Check compressor
Check engine cooling
system
Pressure low
(ªBº area of high side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check for leakage, repair if
necessary and recharge
Check expansion valve
Check compressor
Pressure high
(ªAº area of low side
graph)Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check expansion valve
Check compressor
Pressure low
(ªBº area of low side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
narrow)
Clogged refrigerant passage (Crashed pipe)Check for leakage, repair if
necessary and recharge
Check expansion valve
Repair or replace
Outlet air temperature
at center duct is high
(Crossing point is in
area ªAº)Insufficient or excessive charge of refrigerant
Dirty or bent evaporator fins
Air leakage from cooling (heater) unit or air
duct
Malfunctioning, switchover function of damper
in cooling (heater) unit
Compressor malfunctionCheck refrigerant
pressure
Clean or repair
Repair or replace
Repair or replace
Check compressor
Outlet air temperature
at center duct is low
(Crossing point is in
area ªBº)Insufficient air volume from center duct
(Heater blower malfunction)
Compressor malfunctionCheck blower motor and
fan
Check compressor
NOTE:
If ambient temperature is within 30 ± 35C (85 ± 95F), it is possible to do using next page table for more
detail diagnosis.
Page 99 of 801
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-28 AIR CONDITIONING (OPTIONAL)
8) After the system has been charged with specified amount of re-
frigerant or when low pressure gauge (1) and high pressure
gauge (2) have indicated about 2 and 15 kg / cm
2 respectively,
close low pressure side vale (3) of manifold gauge set (4). If
equipped with sight glass in this time, look into the sight glass (6)
of condenser outlet pipe (5) and check that there are no bubbles
(7) in it, which means that the system is fully charged.
Low pressure gauge when charged with specified amount:
About 200 ± 300 kPa (2 ± 3 kg / cm
2, 29 ± 43 psi)
(At A / C inlet temperature 30 ± 35C, 86 ± 95F)
High pressure gauge when charged with specified amount:
About 1370 ± 1670 kPa (14 ± 17 kg / cm
2, 200 ± 244 psi)
(At A / C inlet temperature 30 ± 35C, 86 ± 95F)
Page 101 of 801

YH4
GRAND
VITARA
1. Suction hose
2. Discharge hose
3. Liquid pipe
4. Condenser outlet pipe
5. Expansion valve
6. Dual pressure switch
7. Suction pipe
: Apply compressor oil
(refrigerant oil) to O-ring.
1B-30 AIR CONDITIONING (OPTIONAL)
ON-VEHICLE SERVICE
WARNING:
Should refrigerant HFC-134a (R-134a) strike your eye(s), consult a doctor immediately.
DO NOT USE YOUR HAND TO RUB AFFECTED EYE(S).
Instead, use quantities of fresh cold water to splash it over affected area to thus gradually raise its
temperature above the freezing point.
Obtain proper treatment as soon as possible from a doctor or eye specialist.
Should liquid refrigerant HFC-134a (R-134a) get on your skin, such affected part should be treated
in the same manner as when skin is frostbitten or frozen.
CAUTION:
None of refrigerant, compressor oil and component parts is interchangeable between two types of A / C:
one using CFC-12 (R-12) and the other using HFC-134a (R-134a).
(For identification between these two types, refer to page 1B-2).
When replenishing or changing refrigerant and compressor oil and when replacing parts, make sure
that the material or the part to be used is appropriate to the A / C installed in the vehicle being serviced.
Use of incorrect one will result in leakage of refrigerant, damage in parts or other faulty condition.
PRECAUTION
When servicing air conditioning system, the following rules must be observed.
PIPING
When connecting hoses and pipes, apply a few drops of compressor oil (refrigerant oil) to seats of coupling nuts
and O-ring.
Never use heat for bending pipes. When bending a pipe, try to make its bending radius as slight as possible.
Keep internal parts of air conditioning free from moisture and dirt. When disconnecting any line from system,
install a blind plug or cap to the fitting immediately.
When tightening or loosening a fitting, use two wrenches, one for turning and the other for support.
Page 105 of 801
YH4
GRAND
VITARA
3
1B-34 AIR CONDITIONING (OPTIONAL)
5) Disconnect coupler from dual pressure switch (1).
6) Disconnect condenser outlet pipe (3).
7) Disconnect condenser cooling fan motor coupler (2).
8) Remove condenser with fan.
NOTE:
Be careful not to damage fins of condenser and radiator.
9) Remove A / C condenser cooling fan assembly from condenser.
INSTALLATION
Reverse removal sequence to install condenser, noting following
point.
1) When replacing condenser, add 20 to 30 cc of refrigerating oil
from compressor suction-side.
2) Evacuate and charge system according to previously-described
procedure.
Page 109 of 801
YH4
GRAND
VITARA
1
1. Ears1. Air flow
1B-38 AIR CONDITIONING (OPTIONAL)
CLEAN
Blow off dust by compressed air from air outlet side of the filter ele-
ment.
INSTALLATION
Reverse removal procedure for installation noting the followings:
Install filter into cooling unit directing arrow mark on its end face
to heater unit.
Enable air bag system after installation. Refer to ªENABLING AIR
BAG SYSTEMº in Section 10B.
Page 112 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-41
INSPECTION
1) Check evaporator fins for blockage. If found clogged, use com-
pressed air to clean the fins.
CAUTION:
Do not use water for cleaning of evaporator.
Be careful not to damage evaporator fins. If evaporator
fin is bent, straighten it by using a screwdriver or pair of
pliers. If any leakage is found from fitting or tube, repair
or replace evaporator.
2) Check inlet and outlet fittings for crack or scratch. Repair them
as required.
REASSEMBLY and INSTALLATION
1) Reverse removal and disassembly sequence to install cooling
unit, noting the following points.
Install uniformly the evaporator packing to dash panel hole for
expansion valve.
Adjust fresh air control cable, refer to ªHEATER CONTROL
LEVER ASSEMBLYº in Section 1A.
2) Enable air bag system. Refer to ªEnabling Air Bag Systemº in
Section 10B.
3) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.
NOTE:
When the thermistor removed, it should be reinstalled in
original position.
If cooling unit or evaporator is replaced, pour 25 cc of refrig-
erating oil to compressor suction-side.