YH4
GRAND
VITARA
8D-26 WINDOWS, MIRRORS, SECURITY AND LOCKS
IGNITION SWITCH AND DOOR SWITCH CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-4 and
When ignition switch is OFF
position0 V
groundWhen ignition switch is ON
position10 ± 14 V
E02 10 andWhen all doors are closedNo continuityE02-10 and
groundWhen any one door is
openedContinuity
If check result is satisfactory, this circuit is OK.
DOOR KNOB SWITCH AND TURN SIGNAL RELAY CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-6 and
groundAnytime10 ± 14 V
E02-11 and
When driver side door lock
knob is pulled upContinuity
groundWhen driver side door lock
knob is pushed downNo continuity
If check result is satisfactory, this circuit is OK.
YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-27
POWER DOOR LOCK SWITCH
INSPECTION
Refer to POWER DOOR LOCK SWITCH INSPECTION of POWER
DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT EQUIPPED)
in this section.
KEY CYLINDER SWITCH (DRIVER SIDE)
INSPECTION
Refer to KEY CYLINDER SWITCH (DRIVER SIDE) INSPECTION
of POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
POWER DOOR LOCK ACTUATOR
INSPECTION
Refer to POWER DOOR LOCK ACTUATOR INSPECTION of
POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.