YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-3
BODY VENTILATION
The body ventilation system of this vehicle has a fresh air intake located at the cowl top panel. When fresh air intake
control lever is at FRESH AIR position, ventilating air is drawn into the interior from the cowl center garnish and
drawn out from the ventilator outlet provided at each side body outer panel (both right and left side).
DIAGNOSIS
DIAGNOSIS TABLE
TroublePossible causeRemedy
Heater blower won't
work even when its
switch is ON.Blower fuse blown
Blower resistor faulty
Blower motor faulty
Wiring or grounding faultyReplace fuse to check for short.
Check resistor.
Replace motor.
Repair as necessary.
Incorrect temperature
output.Control cables broken or binding
Air damper broken
Air ducts clogged
Heater radiator leaking or clogged
Heater hoses leaking or cloggedCheck cables.
Repair damper.
Repair air ducts.
Replace radiator.
Replace hoses.
When mode control
switch is changed,
air outlet port is not
changed.Mode control switch faulty
Mode actuator faulty
Fuse blown
Wiring or grounding faulty
Air damper broken
Air ducts cloggedCheck and replace as necessary.
Check and replace as necessary.
Replace fuse to check for short.
Repair as necessary.
Repair damper.
Repair air ducts.
YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-7
ConditionPossible CauseCorrection
Cool air does not come
out or insufficient
cooling (A / C system
normal operative)Compressor faulty
Air in A / C system
Air leaking from cooling unit or air
duct
Heater and ventilation system faulty
Blower motor faulty
Excessive compressor oil existing in
A / C systemCheck compressor.
Replace condenser dryer, and
evacuation and charging.
Repair as necessary.
Check blower unit.
Check heater control lever assembly.
Check heater assembly.
Check blower motor.
Pull out compressor oil in A / C system
circuit, and replace compressor.
Cool air does not comes
out only intermittentlyWiring connection faulty
Expansion valve faulty
Excessive moisture in A / C system
A / C controller faulty
Magnetic clutch faulty
Excessive charge of refrigerantRepair as necessary.
Check expansion valve.
Replace condenser dryer, and
evacuation and charging.
Check A / C controller.
Check magnetic clutch.
Check charge of refrigerant.
Cool air comes out only
at high speedsCondenser clogged
Insufficient charge of refrigerant
Air in A / C system
Drive belt slipping
Compressor faultyCheck condenser.
Check charge of refrigerant.
Replace condenser dryer, and
evacuation and charging.
Adjust or replace drive belt.
Check compressor.
Cool air does not comes
out only at high speedsExcessive charge of refrigerant
A / C evaporator frostedCheck charge refrigerant.
Check A / C evaporator.
Check A / C thermistor.
Insufficient velocity of
cooled airA / C evaporator clogged or frosted
Air leaking from cooling unit or air
duct
Blower motor faulty
Wiring or grounding faultyCheck A / C evaporator.
Repair as necessary.
Check blower motor.
Repair as necessary.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-9
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
ConditionPossible CauseCorrection
A large rattling noise is heard at
idle or sudden acceleration.Loosen pulley mounting bolt.
Worn or broken bearings.Retighten bolt.
Replace bearings.
ABNORMAL NOISE FROM TENSION PULLEY
ConditionPossible CauseCorrection
Clattering noise is heard from
pulley.
Pulley cranks upon contact.Worn or damaged bearings.
Cracked or loose bracket.Replace bearings.
Replace or retighten bracket.
ABNORMAL NOISE FROM EVAPORATOR
ConditionPossible CauseCorrection
Whistling sound is heard from
evaporator.Depending on the combination of
the interior / exterior
temperatures, engine rpm and
refrigerant pressure, the
refrigerant flowing out of the
expansion valve may, under
certain conditions, make a
whistling sound.At times, slightly decreasing
refrigerant volume may stop this
noise.
Inspect expansion valve and
replace if faulty.
ABNORMAL NOISE FROM BLOWER MOTOR
ConditionPossible CauseCorrection
Blower motor emits a chirping
sound in proportion to its speed of
rotation.
Fluttering noise or large droning
noise is heard from blower motor.Worn or damaged motor brushes
or commutator.
Leaves or other debris
introduced from fresh air inlet to
blower motor.Repair or replace blower motor.
Remove debris and make sure
that the screen at fresh air inlet is
intact.
YH4
GRAND
VITARA
1B-14 AIR CONDITIONING (OPTIONAL)
HIGH PRESSURE CAUGE LOW PRESSURE GAUGE THERMOMETER AT
CENTER DUCT
Insufficient
cooling of
condenser
PERFORMANCE DIAGNOSIS TABLE
TESTING RESULTSPOSSIBLE CAUSEREMEDY
Pressure high
(ªAº area of high side
graph)Refrigerant overcharged
Expansion valve frozen or clogged
Clogged refrigerant passage of high side
Condenser fan malfunction
Dirty or bent condenser fins
Compressor malfunction (Insufficient oil etc.)
Engine overheatRecharge
Check expansion valve
Clean or replace
Check condenser fan
Clean or repair
Check compressor
Check engine cooling
system
Pressure low
(ªBº area of high side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check for leakage, repair if
necessary and recharge
Check expansion valve
Check compressor
Pressure high
(ªAº area of low side
graph)Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check expansion valve
Check compressor
Pressure low
(ªBº area of low side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
narrow)
Clogged refrigerant passage (Crashed pipe)Check for leakage, repair if
necessary and recharge
Check expansion valve
Repair or replace
Outlet air temperature
at center duct is high
(Crossing point is in
area ªAº)Insufficient or excessive charge of refrigerant
Dirty or bent evaporator fins
Air leakage from cooling (heater) unit or air
duct
Malfunctioning, switchover function of damper
in cooling (heater) unit
Compressor malfunctionCheck refrigerant
pressure
Clean or repair
Repair or replace
Repair or replace
Check compressor
Outlet air temperature
at center duct is low
(Crossing point is in
area ªBº)Insufficient air volume from center duct
(Heater blower malfunction)
Compressor malfunctionCheck blower motor and
fan
Check compressor
NOTE:
If ambient temperature is within 30 ± 35C (85 ± 95F), it is possible to do using next page table for more
detail diagnosis.
YH4
GRAND
VITARA
5E1-16 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
-1. Main fuse
-2. Ignition switch
-3. Circuit fuse for IG
-4. ªABSº warning lamp
-5. ABS hydraulic unit / control
module assembly
5-1. Fail-safe relay
5-2. To solenoid valves and
pump motor relay
(ABS hydraulic unit)
-6. Diagnosis connector
(Black connector)
6-1. Diag. switch terminal
6-2. Diag. ground terminal
-7. Combination meter
7-1. ABS lamp driver module
-8. ABS hydraulic unit/
control module connector
of harness
-9. EBD warning lamp
(Brake warning lamp)
-10. Parking brake switch
-11. Brake fluid level switch
TABLE ± A ªABSº WARNING LAMP CIRCUIT CHECK ± LAMP DOES NOT
COME ªONº AT IGNITION SWITCH ON
CIRCUIT DESCRIPTION
Operation (ON / OFF) of the ªABSº warning lamp is controlled by the ABS control module and ABS lamp driver mod-
ule.
If the Antilock brake system is in good condition, the ABS control module turns the ªABSº warning lamp ON at the
ignition switch ON, keeps it ON for 2 seconds only and then turns it OFF. If an abnormality in the system is detected,
the lamp is turned ON by ABS control module. Also, it is turned ON by ABS lamp driver module when the connector
of the ABS control module was disconnected.
INSPECTION
STEPACTIONYESNO
11) Turn ignition switch ON.
Do other warning lamp come ON?Go to step 2.Go to step 4.
21) Disconnect ABS hydraulic unit / control module
connector.
Does ABS warning lamp light with ignition switch ON?Replace ABS
hydraulic unit / control
module assembly.Go to step 3.
31) Remove combination meter.
Is bulb of ABS warning lamp in good condition?ªBl / Oº circuit shorted
to ground. If OK,
replace ABS
warning circuit (lamp
driver module).Replace bulb.
4Is IG fuse in good condition?Open in ªB / Wº wire to
combination meter or
poor connection.Repair and
replace.
YH4
GRAND
VITARA
ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL) 5E1-27
1. ABS hydraulic unit/
control module assembly
2. ABS hydraulic unit/
control module
connector
1. ABS hydraulic
unit / control
module connector
DTC 57 (DTC C1057) ± SOLENOID AND PUMP MOTOR POWER SOURCE
CIRCUIT
DESCRIPTION
The ABS control module monitors the voltage at terminal ( ªA11º and ªA27º) of the fail-safe and pump motor relays
circuit constantly with the ignition switch turned ON. When all solenoid circuit voltages are below the specified value
or the voltage at the terminal ªA27º became below the specified value while the pump motor is operating, this DTC
will be set. As soon as the voltage rises to the specified level, the set DTC will be cleared.
INSPECTION
STEPACTIONYESNO
1Check battery voltage. Is it about 11 V or higher?Go to step 2.Check charging
system referring
to ªCHARGING
SYSTEMº section.
2Check ABS main fuse and connection. Is it in good
condition?Go to step 3.Repair and / or
replace fuse.
31) Ignition switch OFF.
2) Disconnect ABS hydraulic unit / control module
connector. (See Fig. 1)
3) Check proper connection to ABS hydraulic unit /
control module connector at terminal ªA27º.
4) If OK, then measure voltage between connector
terminal ªA27º and body ground.
Is it 10 ± 14 V?Substitute a
known-good
ABS hydraulic
unit / control
module assembly
and recheck.ªW / Blº circuit open.
Fig. 1
YH4
GRAND
VITARA
5E1-32 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
1. ABS hydraulic
unit /control
module
assembly
2. Brake pipe
1. ABS hydraulic
unit / control
module connector 1. Brake pipe
2. ABS hydraulic unit /
control module assembly
3. Bracket
ABS HYDRAULIC UNIT / CONTROL MODULE
ASSEMBLY
CAUTION:
Never disassemble ABS hydraulic unit / control module as-
sembly, loosen blind plug or remove motor. Performing any
of these prohibited services will affect original performance
of ABS hydraulic unit / control module assembly.
HYDRAULIC UNIT INSPECTION
Check hydraulic unit for fluid leakage.
If any, repair or replace.
REMOVAL
1) Disconnect negative cable at battery.
2) Using special tool, disconnect brake pipes from ABS hydraulic
unit / control module assembly and loosen flare nuts as shown
figure.
Special Tool
(A): 09950-78220
NOTE:
Put bleeder plug cap onto pipe to prevent fluid from spilling.
Do not allow brake fluid to get on painted surfaces.
3) Disconnect ABS hydraulic unit / control module assembly con-
nector.