JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual The spring type hose clamp applies constant ten-
sion on a hose connection. To remove a spring type
hose clamp, only use constant tension clamp pliers
designed to compress the hose clamp.
DIAGNOSIS AN

Page 247 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual ENGINE
TABLE OF CONTENTS
page page
COOLANT
DESCRIPTION
DESCRIPTION - ENGINE COOLANT.......25
DESCRIPTION - HOAT COOLANT.........25
OPERATION...........................26
COOLANT LEVEL SENSOR
REMOVAL..

Page 251 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual ²Fan control valve
²Two stage G-rotor hydraulic drive
The hydraulic fan and drive is not serviceable.
Therefore any failure of the fan blade, hydraulic fan
drive or fan shroud requires replacement o

Page 258 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual (2) Insert block heater assembly with element loop
pointing at twelve oclock (Fig. 19).
(3) With block heater fully seated, tighten center
screw to 2 N´m (17 in. lbs.) torque.
(4) Refill cooling sys

Page 260 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual The same thermostat is used for winter and sum-
mer seasons. An engine should not be operated with-
out a thermostat, except for servicing or testing.
Operating without a thermostat causes other prob-

Page 264 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual (6) Start the engine and operate at 2400 rpm.
Within ten minutes the air temperature (indicated on
the dial thermometer) should be up to 93É C (200É F).
Fan driveengagementshould have started to occ

Page 265 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual INSTALLATION
(1) Position relay to body and install 2 bolts.
Tighten bolts to 3 N´m (25 in. lbs.) torque.
(2) Connect electrical connector to relay.
(3) Connect vacuum hose to reservoir.