2003 HONDA CIVIC evap

[x] Cancel search: evap

Page 372 of 1139

HONDA CIVIC 2003 7.G Workshop Manual Throttle Body Removal/lnstallation
NOTE: Do not adjust the throttle stop screw.. Afterreassembly,adjustthethrottlecable{seepagell-163) and the cruise control cable (see page 4-45).. The throttle posi

Page 373 of 1139

HONDA CIVIC 2003 7.G Workshop Manual Intake Air System
Throttle Body Disassembly/Reassembly
EVAPORATIVE EMISSION {EVAP)CANISTER PURGE VALVE
A
V
2 N.m{0.2 kgt m, 1 lbf.ft)
3.5 N.m(0.35 kgf m.2.5lbf ft)
MAP SENSOR
THROTTLE BODY
L
TP SENSOR

Page 375 of 1139

HONDA CIVIC 2003 7.G Workshop Manual PCV System
DTC Troubleshooting
DTC P1505: PCV Air Leakage
1. Reset the ECM (see page 11-4).
2. Start the engine. Hold the engine at 3,000 rpm with
no load (in neutral) until the radiator fan comes on

Page 377 of 1139

HONDA CIVIC 2003 7.G Workshop Manual EVAP System
Component Location Index
EVAPORATIVE EMISSION {EVAP)CANISTER VENT SHUT VALVETroubleshooting,step 23 on page 1l 178,step 1g on page l1- 182
EVAPORATIVE EMISSION IEVAPICANISTER PURGE VALVET

Page 378 of 1139

HONDA CIVIC 2003 7.G Workshop Manual DTC Troubleshooting
DTC P0451: FTP Sensor Range/Performa nce
Problem
Special Tools Required
Vacuum Pump/Gauge, 0-30 in. Hg A973X-041-XXXXX
1. Remove the fuel fill cap.
2. Turn the ignition switch ON (

Page 379 of 1139

HONDA CIVIC 2003 7.G Workshop Manual EVAP System
DTC Troubleshooting (contd)
DTC P0452: FTP Sensor Circuit Low Voltage
1. Check the vacuum lines at the FTP sensor for
misrouting, leakage. breakage, or clogging.
Are the vacuum lines OK?

Page 381 of 1139

HONDA CIVIC 2003 7.G Workshop Manual EVAP System
DTC Troubleshooting (contdl
6. Turn the ignition switch OFF.
7. Reinstall lhe fuel fill cap.
8. Disconnect the FTP sensor 3P connector.
9. Turn the ignition switch ON (ll).
10. l\4easure

Page 382 of 1139

HONDA CIVIC 2003 7.G Workshop Manual DTC Pl456: EVAP Control(Fuel Tank Svstem)
System Leakage
The fuel system is designed to allow specified
maximum vacuum and pressure conditions. Do not
deviate from the vacuum and pressure tests as
ind