MANUAL CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM 7B–17
DAEWOO M-150 BL2
SERVICEABLE
COMPONENTS
(Left–Hand Drive Shown, Right–Hand
Drive Similar)
CONTROL ASSEMBLY AND
CONTROL CABLES
To remove the control assembly and control cables, re-
fer to Section 7A, Heating and Ventilation System (With-
out Air Conditioning).
BLOWER MOTOR AND COOLING
HOSE
To remove the blower motor and cooling hose, refer to
Section 7A, Heating and Ventilation System (Without Air
Conditioning).
BLOWER RESISTOR
To remove the blower resistor, refer to Section 7A, Heat-
ing and Ventilation System (Without Air Conditioning).
BLOWER MOTOR SWITCH
To remove the blower motor switch, refer to Section 7A,
Heating and Ventilation System (Without Air Condition-
ing).
7B -- 30 MANUAL CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM
DAEWOO M-150 BL2
SPECIFICATIONS
GENERAL SPECIFICATIONS
Application
Unit
Description
Compressor
--
SP--10.4PK
Receiver--Dryer
--
AL R/DRIER
Refrigerant
Type
--
R--134a System
Refrigerant
Capacity
g
500 (RHD : 530)
RefrigerantOilinA/CSystem
Type
--
RL 244 PAG OIL RefrigerantOilinA/CSystem
Capacity
cc
150
A/C Cooling Capacity (Airflow rate 8.7 kg/min)
Kcal/h
5,500
Refrigerant Pressure in A/C Sys-
tem(Engine Idle, Fresh Air 30_C
(86_F)AmbientTemperature
Low Pressure Side
kPa (psi)
200 (2.9)
(86_F),AmbientTemperature
25_C--35_C(77_F--95_F), Tempera-
ture to Full Cold)
High Pressure Side
kPa (psi)
1,500 (217.5)
A/C Compressor ON/OFF Condition
(Refer toSection 1F, Engine Controls
AbouttheA/CCompressorON/OFF
Evaporator Therm-
istor Temperature
_C(_F)
2.45(36.81)
1.0 (34.2)
ON
OFF
About theA/CCompressorON/OFF
Condition According to Engine Oper-
ating Status)
Dual Cut Switch
Pressure
kPa
205--245
180--220
ON
OFF300--400
240--280
FASTENER TIGHTENING SPECIFICATIONS
Application
NSm
Lb-Ft
Lb-In
Compressor Upper Bracket Bolts
20
15
--
Compressor Front Head-to-Rear Head Through-Bolt
22
16
--
High Pressure Pipe Line (Compressor→Condenser) Bolt
23
17
--
High Pressure Pipe Line (Compressor→Condenser) Fitting
23
17
--
High Pressure Pipe Line (Compressor→Condenser) Clamp Nut
5
--
44
Receiver--Dryer Flange Nut
14
10.5
--
High Pressure Pipe Line (Condenser→Receiver--Dryer) Fitting Nut
14
10.5
--
High Pressure Pipe Line (Receiver--Dryer→Evaporator) Fitting Nut
14
10.5
--
High Pressure Pipe Line(Receiver--Dryer→Evaporator) Clamp Nut
5
--
44
Low Pressure Pipe Line (Evaporator→Compressor) Fitting Nut
14
10.5
--
Low Pressure Pipe Line (Evaporator→Compressor) Clamp Nut
5
--
44
Low Pressure Pipe Line(Evaporator→Compressor) Compressor Bolt
23
17
--
Dual Cut Switch
13
--
11 5
Receive--Dryer Bracket--to--Body Bolts
5
--
44
Receive--Dryer Bracket Bolt
5
--
44
Expansion Valve Coupling (Receiver--Dryer→Expansion Valve)
17
13
--
Expansion Valve Coupling (Expansion Valve→Evaporator)
22
16
--
Compressor Shaft Bolt
13
--
11 5
Condenser Mounting Nuts
4
--
36