Page 21 of 72

5-1
5
EAU00372
5-OPERATION AND IMPORTANT RIDING POINTS
EAU00373*
WARNING
_
Become thoroughly familiar
with all operating controls and
their functions before riding.
Consult a Yamaha dealer re-
garding any control or function
that you do not thoroughly un-
derstand.
Never start the engine or oper-
ate it in a closed area for any
length of time. Exhaust fumes
are poisonous, and inhaling
them can cause loss of con-
sciousness and death within a
short time. Always make sure
that there is adequate ventila-
tion.
For safety, always start the en-
gine with the centerstand.
Before starting out, make sure
that the sidestand is up. If the
sidestand is not raised com-
pletely, it could contact the
ground and distract the opera-
tor, resulting in a possible loss
of control.
_
EAU00416*
Starting and warming up a
cold engine
EC000046
CAUTION:_ See page 5-4 for engine break-in in-
structions prior to operating the ve-
hicle for the first time. _1. Turn the key to “ON”.
2. Turn on the starter (choke) and
completely close the throttle grip.
(See page 3-6 for starter (choke)
operation.)3. Start the engine by pushing the
start switch, while applying the
front or rear brake or by pushing
the kickstarter lever down.
NOTE:_ If the engine fails to start, release the
start switch, wait a few seconds, and
then try again. Each starting attempt
should be as short as possible to pre-
serve the battery. Do not crank the en-
gine more than 5 seconds on any one
attempt. If the engine does not start
with the starter motor, try using the
kickstarter with the motorcycle on the
centerstand. _
1. Starter (choke) lever “”
1. Start switch “START”
2. Kickstarter
U5MXE0.book Page 1 Thursday, December 20, 2001 2:08 PM
Page 58 of 72

PERIODIC MAINTENANCE AND MINOR REPAIR
6-31
610. Place the breather hose into the
original position and make sure
that it is properly routed.
11. Hook the battery band onto the
holder.
12. Install the panel.
To store the battery
1. If the motorcycle will not be used
for more than one month, remove
the battery, fully charge it, and
then place it in a cool, dry place.2. If the battery will be stored for
more than two months, check the
specific gravity of the electrolyte at
least once a month and fully
charge the battery whenever nec-
essary.
3. Fully charge the battery before in-
stallation.
4. After installation, make sure that
the battery leads are properly con-
nected to the battery terminals and
that the breather hose is properly
routed, in good condition, and not
obstructed.
EC000099
CAUTION:_ If the breather hose is positioned in
such a way that the frame is ex-
posed to electrolyte or gas expelled
from the battery, the frame could
suffer structural and external dam-
ages. _
EAU01307*
Replacing the fuse The fuse is located behind panel A.
(See page 6-4 for panel removal and
installation procedures.)
If the fuse is blown, replace it as fol-
lows.
1. Turn the key to “OFF” and turn off
all electrical circuits.
2. Pull the battery out of the battery
compartment. (See page 6-29, “To
check the electrolyte level” for bat-
tery removal and installation pro-
cedures.)
1. Battery breather hoseU5MXE0.book Page 31 Thursday, December 20, 2001 2:08 PM
Page 59 of 72
PERIODIC MAINTENANCE AND MINOR REPAIR
6-32
6 3. Pull the starter relay out.
4. Remove the blown fuse, and then
install a new fuse of the specified
amperage.
EC000103
CAUTION:_ Do not use a fuse of a higher amper-
age rating than recommended to
avoid causing extensive damage to
the electrical system and possibly a
fire. _
5. Place the starter relay into the
original position.
6. Place the battery in the battery
compartment.
7. Turn the key to “ON” and turn on
the electrical circuits to check if the
devices operate.
8. If the fuse immediately blows
again, have a Yamaha dealer
check the electrical system.
1. Starter relay
1. Fuse
2. Spare fuseSpecified fuse: 10 A
U5MXE0.book Page 32 Thursday, December 20, 2001 2:08 PM