COMPRESSION SYSTEM DIAGNOSIS
Compressor troubles are mainly following three types: gas leakage, noise and insufficient pressure.
Compressor gas leakages in most cases develop from the shaft seal. When detecting gas leakage, always use
a leak tester. If a small amount of oil seeps out from the shaft seal, there is no necessity of replacing the seal. The
shaft seal has been designed to allow a small amount of oil to leak out for lubricating purpose. Thus, the shaft seal
should be replaced only when a large amount of compressor oil is leaking out or when gas leakage is discovered
by using gas tester.
In regard to noise and insufficient pressure, repairs should be made only after diagnosing the trouble properly.
CONDITION
POSSIBLE CAUSESCORRECTION
Noise from compressorDefective bearing
Defective cylinder and / or shaftReplace.
Replace.
Noise from magnetic clutchDefective bearing
Defective clutch faceReplace.
Replace.
Insufficient coolingDefective gasketReplace.
Defective reed valveReplace.
Not rotatingLocked compressor
Seized magnetic clutch
Rotating parts seized by insufficient oil
amountReplace.
Replace.
Replace.
Oil and / or gas leakageDefective seal
Defective O-ringReplace.
Replace.
Page 154 of 801

YH4
GRAND
VITARA
1. P / S fluid reservoir
2. Attachment
3. Gasket4. Union bolt
5. High pressure side
6. Low pressure side
1. P / S fluid reservoir
2. Gauge valve (open)
3. P / S pump4. P / S gear box
5. High pressure side
6. Low pressure side
3B1-10 POWER STEERING (P / S) SYSTEM
HYDRAULIC PRESSURE IN P / S CIRCUIT
HYDRAULIC PRESSURE CHECK
1) After cleaning joint of high pressure hose and P / S pump thor-
oughly, disconnect hose from pump and install special tool (oil
pressure gauge, attachment and hose).
Tighten each flare nut to specified torque.
CAUTION:
Take care not to cause damage to A / C condenser during
service operation, if equipped.
Special Tool
(A): 09915-77410 (Oil pressure gauge)
(B): 09915-77420
2) Check each connection for fluid leakage and bleed air.
Refer to ªAIR BLEEDING PROCEDUREº in this section.
3) With engine idling, turn steering wheel and warm up engine till
temperature of fluid in P/S fluid reservoir rises to 50 ± 60C (122
± 140F).
4) Check back pressure by measuring hydraulic pressure with en-
gine idling and hands off steering wheel.
Back pressure: Lower than 1000 kPa (10 kg / cm
2, 142 psi)
When back pressure is higher than specified values, check con-
trol valve and piping for clogging.
Page 467 of 801

YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-65
1. Drain plug
2. Propeller shaft
1. Oiler (with transmission fluid)
2. Solenoid valve
3. BatteryA: Hole (Should be dry)
B: Exhausting fluid Terminal Arrangement of PCM Coupler
(Viewed from harness side)
WITH BATTERY VOLTAGE WITHOUT BATTERY VOLTAGE
H25 Engine
Shift solenoid valve ± A (#1)C51-1-6
Shift solenoid valve ± B (#2)C51-1-1
TCC (Lock-up) solenoid valveC51-1-2
REMOVAL
1) Pull out dipstick and lift up vehicle.
2) With engine cooled, remove drain plug from oil pan and drain
A / T fluid.
3) Install drain plug with gasket.
Tightening Torque
(a): 23 N
.m (2.3 kg-m, 17.0 lb-ft)
4) Remove exhaust pipe bracket and disconnect front propeller
shaft from front differential (if equipped).
5) Remove oil pan bolts.
6) Remove oil pan.
7) Remove oil tubes.
8) Remove solenoid valve No.1 (shift solenoid valve A and B) or so-
lenoid valve No.2 (TCC solenoid valve).
OPERATION CHECK
Whenever shift solenoid valves and TCC (lock-up) solenoid valve
are removed from transmission, verify their valve function physical-
ly before they are reinstalled.
1) Apply oiler to solenoid valve and give compression by hands
and then check to be sure that transmission fluid from oiler does
not come out of holes in solenoid valve when battery voltage is
not conducted.
2) Under the same conditions as above, conduct battery voltage
and then make sure that fluid comes out with vigor.
NOTE:
If fluid does not come out with vigor in above step 2 in-
spection, do not re-use that solenoid valve.
Figure at the left shows shift solenoid valve check.
Check TCC solenoid valve also in the same way.
Page 468 of 801
YH4
GRAND
VITARA
7B1-66 AUTOMATIC TRANSMISSION (4 A / T)
14
2
3
INSTALLATION
Reverse removal procedure to install solenoid valves and noting
the following points.
For details of solenoid valve installation, refer to ªUnit Repairº
section. Use new gasket and O-ring.
Install oil tubes in such order as shown in figure.
For details of oil pan installation, refer to ªUnit Repairº section.
Use new oil pan gasket.
Tighten universal joint flange bolts & nuts and exhaust pipe brack-
et bolts to specified torque.
Fill A / T fluid and check fluid level according to procedure de-
scribed in ªCHANGING FLUIDº previously.
Check for fluid leakage after warming up A / T.
THROTTLE POSITION SENSOR
INSPECTION
Refer to SECTION 6E1 / 6E2 for inspection.
POWER / NORMAL CHANGE SWITCH
INSPECTION
Check Power / Normal change switch for operation referring to Step
4 of Diag. Flow Table B-4 in this section.
If malfunction is found, replace.