Page 725 of 801

YH4
GRAND
VITARA
(A)ªA5º
1. Combination meter connector (16p)
2. ªY / Gº wire terminal1. Connection detection pin
AIR BAG SYSTEM 10B-19
TABLE B ± ªAIR BAGº WARNING LAMP DOES NOT COME ªONº (Page 2 of 2)
STEPACTIONYESNO
41) Remove combination meter, referring to
SECTION 8C.
2) Check proper connection to combination
meter at terminal for ªAIR BAGº warning lamp
and to SDM at terminal ªA5º.
3) If OK then check resistance between ªY / Gº
wire terminal of combination meter connector
(16p) and ªA5º terminal of SDM connector.
4) Is resistance 1 or less?Go to step 5.Repair high resistance
or open in ªBIº or ªY / Gº
wire circuit (between
combination meter and
SDM).
51) Measure voltage from ªA5º terminal of SDM
connector to body ground with ignition switch
ON.
2) Is it 9 V or more?Repair short from ªBIº or
ªY / Gº wire circuit
(between combination
meter and SDM) to
power circuit.Go to step 6.
61) Remove and inspect ªAIR BAGº bulb.
2) Is bulb good?Substitute a known-good
combination meter and
recheck.Replace bulb.
Fig. for STEP 2 Fig. for STEP 3 and 5
Fig. for STEP 4
Special Tool
(A): 09932-76010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.
Page 729 of 801

YH4
GRAND
VITARA
1. DLC
2. Scan tool1. ªW/Bº wire terminal
AIR BAG SYSTEM 10B-23
TABLE D ± SDM CANNOT COMMUNICATE THROUGH THE SERIAL DATA CIRCUIT
(Page 2 of 2)
STEPACTIONYESNO
21) Check if communication is possible by
trying communication with other
controller (ECM (or PCM), ICM or ABS
controller).
2) Is it possible to communicate with other
controller?Go to step 3.Repair open in common
section of serial data circuit
(ªW/Bº wire circuit) used by
all controllers or short to
ground or power circuit
which has occurred some-
where in serial data circuit
(ªW/Bº wire circuit).
31) With ignition switch OFF, disconnect
SDM and ªLamp, DLC and Monitor
Coupler Groundº (ªEº) connector.
2) Check proper connection at ªW/Bº wire
terminal for DLC in ªEº connector.
3) If OK, then check resistance between
ªW/Bº wire terminal in ªEº connector and
ªA4º terminal of SDM connector.
4) Is resistance 1 or less?Substitute a known-good
SDM and recheck.Repair high resistance or
open in ªW/Bº wire circuit
(in air bag harness).
Fig. for STEP 1 Fig. for STEP 3
Special Tool
(A): 09932-76010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.
Page 736 of 801
YH4
GRAND
VITARA
1. From ignition switch
2. ªAIR BAGº fuse in ªAIR BAGº fuse box
3. SDM
4. Passenger air bag (inflator) module: Shorting bar
: Air bag harness
10B-30 AIR BAG SYSTEM
CODE 19 ± PASSENGER AIR BAG INITIATOR CIRCUIT SHORT TO POWER CIRCUIT
(Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The voltage measured at passenger air bag initiator circuit is above a specified value for specified time.
Page 737 of 801

YH4
GRAND
VITARA
(A)STEERING WHEEL
AIR BAG SYSTEM 10B-31
CODE 19 ± PASSENGER AIR BAG INITIATOR CIRCUIT SHORT TO POWER CIRCUIT
(Page 2 of 2)
NOTE:
Before executing items in this table, be sure to perform ªAir Bag Diagnostic Check Flow Tableº.
STEP
ACTIONYESNO
11) With ignition switch OFF, disconnect
passenger air bag (inflator) module
connector behind the glove box.
2) Check proper connection to passenger
air bag (inflator) module at terminals in ªBº
connector.
3) If OK then connect Special Tool (B) to
passenger air bag (inflator) module
connector disconnected at the step 1).
4) With ignition switch ON, is DTC 19
current?Go to step 2.1) Ignition switch OFF.
2) Replace passenger air
bag (inflator) module.
21) With ignition switch OFF, disconnect
Special Tool (B) and SDM.
2) Measure voltage from ªA3º terminal to
body ground.
3) With ignition switch ON, is voltage 1 V or
less?Substitute a known-good
SDM and recheck.Repair short from ªYº or
ªY/Rº wire circuit to power
circuit.
Fig. for STEP 1 and 2 Fig. for STEP 2
Special Tool
(A): 09932-76010
(B): 09932-75010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Clear diagnostic trouble codes (refer to ªDiagnostic Trouble Code (DTC) Clearanceº), if any.
3) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.
Page 744 of 801

YH4
GRAND
VITARA
: Shorting bar
: Air bag harness
1. From ignition switch
2. ªAIR BAGº fuse in ªAIR BAGº fuse box
3. SDM
4. Contact coil assembly
5. Driver air bag (inflator) module
10B-38 AIR BAG SYSTEM
CODE 25 ± DRIVER AIR BAG INITIATOR CIRCUIT SHORT TO POWER CIRCUIT (Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The voltage measured at driver air bag initiator circuit is above a specified value for specified time.
NOTE:
Before executing items in this table, be sure to perform ªAir Bag Diagnostic Check Flow Tableº.
STEP
ACTIONYESNO
11) With ignition switch OFF, disconnect contact
coil connector located near the base of the
steering column.
2) Check proper connection to contact coil at
terminals in ªCº connector.
3) If OK then connect Special Tool (B) to contact
coil connector disconnected at step 1).
4) With ignition switch ON, is DTC 25 current?Go to step 2.Go to step 3 on the
next page.
21) With ignition switch OFF, disconnect Special
Tool (B) and SDM.
2) Measure voltage from ªA7º terminal to body
ground.
3) With ignition switch ON, is voltage 1 V or less?Substitute a known-
good SDM and
recheck.Repair short from ªGº or
ªG/Rº wire circuit to
power circuit.
Page 745 of 801

YH4
GRAND
VITARA
AIR BAG SYSTEM 10B-39
(A)
STEERING
WHEELBASE OF COLUMN
CODE 25 ± DRIVER AIR BAG INITIATOR CIRCUIT SHORT TO POWER CIRCUIT (Page 2 of 2)
STEPACTIONYESNO
31) With ignition switch OFF, disconnect Special
Tool (B) then reconnect contact coil connector
located near the base of the steering column.
2) Remove driver air bag (inflator) module from
steering wheel (Refer to SECTION 3C1).
3) Check proper connection to driver air bag
(inflator) module at terminals in ªDº connector.
4) If OK then connect Special Tool (B) to driver
air bag (inflator) module disconnected at
step 2).
5) With ignition switch ON, is DTC 25 current?1) Ignition switch OFF.
2) Replace contact coil
assembly (Refer to
SECTION 3C1).1) Ignition switch OFF.
2) Replace driver air bag
(inflator) module
(Refer to SECTION
3C1).
Fig. for STEP 1 and 2 Fig. for STEP 2
Fig. for STEP 3
Special Tool
(A): 09932-76010
(B): 09932-75010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Clear diagnostic trouble codes (refer to ªDiagnostic Trouble Code (DTC) Clearanceº), if any.
3) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.
Page 746 of 801
YH4
GRAND
VITARA
: Air bag harness
1. From main fuse
2. Ignition switch
3. ªAIR BAGº fuse in ªAIR BAGº fuse box
4. SDM
10B-40 AIR BAG SYSTEM
CODE 31 ± POWER SOURCE VOLTAGE HIGH (Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The power source voltage to SDM is above specified value for specified time.
Page 747 of 801

YH4
GRAND
VITARA
(A)
AIR BAG SYSTEM 10B-41
CODE 31 ± POWER SOURCE VOLTAGE HIGH (Page 2 of 2)
NOTE:
Before executing items in this table, be sure to perform ªAir Bag Diagnostic Check Flow Tableº.
STEP
ACTIONYESNO
11) With ignition switch OFF, disconnect SDM.
2) Check proper connection to SDM at
ªA16º terminal.
3) If OK then ignition switch ON, and then check
voltage from ªA16º terminal on SDM harness
connector to body ground.
4) Is voltage 14 V or less?Go to step 2.Check Charging System
and repair as necessary.
(Refer to SECTION 6H
ªChanging Systemº)
21) With ignition switch OFF, reconnect SDM
2) With ignition switch ON, is DTC 31 current?Substitute a known-
good SDM and recheck.Check Charging System
and repair as necessary.
(Refer to SECTION 6H
ªChanging Systemº)
Fig. for STEP 1
Special Tool
(A): 09932-76010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Clear diagnostic trouble codes (refer to ªDiagnostic Trouble Code (DTC) Clearanceº), if any.
3) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.