2002 SUZUKI GRAND VITARA compressor

[x] Cancel search: compressor

Page 103 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
1. New compressor
2. Removed compressor
3. Excess oil (A ± B)
1B-32 AIR CONDITIONING (OPTIONAL)
REPLENISHING COMPRESSOR OIL
When replacing air conditioning parts with new ones, it is

Page 104 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
2. Bolt
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-33
A / C CONDENSER ASSEMBLY
INSPECTION
Check
a) condenser fins for blockage
b) condense

Page 105 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
3
1B-34 AIR CONDITIONING (OPTIONAL)
5) Disconnect coupler from dual pressure switch (1).
6) Disconnect condenser outlet pipe (3).
7) Disconnect condenser cooling fan motor coupler (2)

Page 107 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
12
2. Condenser dryer section
1B-36 AIR CONDITIONING (OPTIONAL)
CONDENSER DRYER (RECEIVER / DRYER)
REMOVAL
1) Remove A / C condenser assembly (1) from vehicle (Refer to
ªA / C CONDEN

Page 110 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-39
COOLING UNIT (EVAPORATOR)
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Disable air bag system. Refer to ªDisabling Air Bag Systemº in
S

Page 112 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-41
INSPECTION
1) Check evaporator fins for blockage. If found clogged, use com-
pressed air to clean the fins.
CAUTION:
Do not use water for cleaning of

Page 113 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
3. Pipe clamp
1B-42 AIR CONDITIONING (OPTIONAL)
EXPANSION VALVE
INSPECTION
Refer to ªTroubleshooting Procedure Using Manifold Gauge Setº in
this section.
REMOVAL
1) Recover refriger

Page 115 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
1B-44 AIR CONDITIONING (OPTIONAL)
REFRIGERANT PIPES AND HOSES
INSPECTION
1) Use a leak tester to check hoses and pipes for any gas leakage.
2) Check each hose or pipe clamp for tightn