YH4
GRAND
VITARA
8D-24 WINDOWS, MIRRORS, SECURITY AND LOCKS
STEPACTIONYESNO
10Check that hazard warning lights flash with hazard
switch ON.
Is check result OK?Go to Step 11.Refer to ªTurn Signal
and Hazard Warning
Lightsº in DIAGNOSIS
and repair.
And go to Step 4.
11Check door knob switch and turn signal relay
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
POWER DOOR LOCK OPERATION
INSPECTION
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
KEYLESS ENTRY OPERATION
INSPECTION
1) With the IG switch OFF and all doors closed, push LOCK button
on transmitter. Check all power doors are locked.
2) Push UNLOCK button on transmitter. Check only driver side
power door is unlocked.
3) Push UNLOCK button on transmitter again within 5 seconds.
Check all power doors are unlocked.
But if any door is not opened within 30 seconds after power
door(s) unlocked, all power doors are locked again automatical-
ly.
If check result of Step 1) to Step 3) is satisfactory, this operation is
OK.
HAZARD WARNING LIGHTS OPERATION
INSPECTION
1) Check that hazard warning lights flash one time when power
doors are locked by pushing LOCK button on transmitter.
2) Check that hazard warning lights flash two times when power
door(s) is (are) unlocked by pushing UNLOCK button on trans-
mitter.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
YH4
GRAND
VITARA
8D-26 WINDOWS, MIRRORS, SECURITY AND LOCKS
IGNITION SWITCH AND DOOR SWITCH CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-4 and
When ignition switch is OFF
position0 V
groundWhen ignition switch is ON
position10 ± 14 V
E02 10 andWhen all doors are closedNo continuityE02-10 and
groundWhen any one door is
openedContinuity
If check result is satisfactory, this circuit is OK.
DOOR KNOB SWITCH AND TURN SIGNAL RELAY CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-6 and
groundAnytime10 ± 14 V
E02-11 and
When driver side door lock
knob is pulled upContinuity
groundWhen driver side door lock
knob is pushed downNo continuity
If check result is satisfactory, this circuit is OK.