2002 SUZUKI GRAND VITARA Top

[x] Cancel search: Top

Page 51 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
0B-24 MAINTENANCE AND LUBRICATION
FINAL INSPECTION
Seats
Check that seat slides smoothly and locks securely at
any position. Also check that reclining mechanism of
front seat back all

Page 55 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-3
BODY VENTILATION
The body ventilation system of this vehicle has a fresh air intake located at the cowl top panel. When fresh air intake
control lever is a

Page 64 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
1A-12 HEATER AND VENTILATION
1. Temperature control lever
2. Fresh air control lever
1. Fresh air control cable 1. Heater unit
2. Control cable1
2
INSTALLATION
1) Install in reverse o

Page 80 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-9
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
ConditionPossible CauseCorrection
A large rattling noise is heard at
idle or sudden acceleration.Loosen pulley

Page 91 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
1B-20 AIR CONDITIONING (OPTIONAL)
A / C CONTROLLER VOLTAGE VALUES TABLE
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC1-1B/WController main
power supplyGround to
engine

Page 92 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150

Page 96 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
AIR CONDITIONING (OPTIONAL) 1B-25
EVACUATING
EVACUATING PROCEDURE
CAUTION:
Do not evacuate before recovering refrigerant in sy

Page 97 of 801

SUZUKI GRAND VITARA 2002 2.G Service Workshop Manual YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-26 AIR CONDITIONING (OPTIONAL)
CHARGING
CAUTION:
ALWAYS CHARGE THROUGH LOW PRESSURE-SIDE of A / C system at after the init
Page:   < prev 1-8 9-16 17-24 25-32 33-40 41-48 ... 128 next >