JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (5) Disconnect the rubber hose from the power
steering reservoir (Fig. 12).
(6) Remove the hose from the vehicle.
REMOVAL - 3/8(GEAR OUTLET HOSE
(1) Drain the power steering fluid from the reser-
voir

Page 1518 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual INSTALLATION - 3/8(PRESSURE HOSE
NOTE: Lubrication and a new o-ring must be used
when reinstalling.
(1) Install the hoses to the vehicle.
(2) Reconnect the high pressure hose to the
hydraulic fan moto

Page 1653 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual TORQUE CONVERTER
DRAINBACK VALVE
DESCRIPTION
The drainback valve is located in the transmission
cooler outlet (pressure) line.
OPERATION
The valve prevents fluid from draining from the
converter into

Page 1687 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (3) Install the ECE check ball into the transfer
plate (Fig. 301). The ECE check ball is approximately
4.8 mm (3/16 in.) in diameter.
(4) Position lower housing separator plate on
transfer plate (Fig.

Page 1703 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (12) Disconnect gearshift cable from transmission
manual valve lever (Fig. 9).
(13) Disconnect transfer case shift cable from the
transfer case shift lever (Fig. 10).
(14) Remove the clip securing the

Page 1714 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (37) Using Alignment Plate 8261, Adapter 8266-17
from End-Play Tool Set 8266 and Dial Indicator
C-3339, measure and record the output shaft end-
play (Fig. 43). The correct output shaft end-play is
0.

Page 1715 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (45) Using Adapter 8266-1 from End-Play Tool Set
8266 and Dial Indicator C-3339, measure and record
the input shaft end-play (Fig. 46). The correct end-
play is 0.46-0.89 mm (0.018-0.035 in.). Adjust

Page 1717 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (5) Carefully insert converter in oil pump. Then
rotate converter back and forth until fully seated in
pump gears.
(6) Check converter seating with steel scale and
straightedge (Fig. 52). Surface of c