2002 JEEP GRAND CHEROKEE Engine control module

[x] Cancel search: Engine control module

Page 1698 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual TRANSMISSION IDENTIFICATION
Transmission identification numbers are stamped
on the left side of the case just above the oil pan
sealing surface (Fig. 1). Refer to this information
when ordering replac

Page 1763 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (23) Install the reverse clutch pack into the input
clutch retainer (Fig. 77).
(24) Install the reverse reaction plate into the
input clutch retainer.
(25) Install the reverse reaction plate selective

Page 1773 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual OUTPUT SPEED SENSOR
DESCRIPTION
The Input and Output Speed Sensors are two-wire
magnetic pickup devices that generate AC signals as
rotation occurs. They are mounted in the left side of
the transmissi

Page 2079 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual OPERATION
OPERATION - HEATER AND AIR CONDITIONER
Outside fresh air enters the vehicle through the
cowl top opening at the base of the windshield, and
passes through a plenum chamber to the HVAC sys-
t

Page 2090 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual A/C COMPRESSOR CLUTCH
DESCRIPTION
The compressor clutch assembly consists of a sta-
tionary electromagnetic coil, a hub bearing and pul-
ley assembly, and a clutch plate (Fig. 4). The
electromagnetic

Page 2093 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual gap should be between 0.35 to 0.65 millimeter (0.014
to 0.026 inch). If the proper air gap is not obtained,
add or subtract shims as needed until the desired air
gap is obtained.
(9) Install the compr

Page 2095 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual Both the manual A/C Heater control panel and the
AZC control panel are serviced only as complete
units and cannot be repaired. If faulty or damaged,
the entire control panel unit must be replaced.
DIA

Page 2097 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual HISTORICAL FAULT CODES
Input faults 33 = IR thermister circuit was open
34 = IR thermister circuit was shorted
35 = Fan pot was shorted
36 = Fan pot was open
37 = Mode pot was shorted
38 = Mode pot wa