2002 JEEP GRAND CHEROKEE Valve cover

[x] Cancel search: Valve cover

Page 1684 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual VALVE BODY LOWER HOUSING
(1) Remove timing valve cover.
(2) Remove 3-4 timing valve and spring.
(3) Remove 3-4 quick fill valve, spring and plug.
(4) Remove 3-4 shift valve and spring.
(5) Remove conv

Page 1685 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual Wipe the governor pressure sensor and solenoid
valve with dry, lint free shop towels only. The O-rings
on the sensor and solenoid valve are the only service-
able components. Be sure the vent ports in

Page 1688 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual UPPER HOUSING VALVE AND PLUG
Refer to (Fig. 318), (Fig. 319) and (Fig. 320) to per-
form the following steps.
(1) Lubricate valves, plugs, springs with clean
transmission fluid.
(2) Assemble regulator

Page 1689 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (6) Install limit valve housing and cover plate.
Tighten screws to 4 N´m (35 in. lbs.).
(7) Install shuttle valve as follows:
(a) Insert plastic guides in shuttle valve second-
ary spring and install

Page 1690 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual Fig. 320 Upper Housing Shift Valve And Pressure Plug Locations
1 - UPPER HOUSING 8 - RETAINER
2 - 1-2 SHIFT VALVE AND SPRING 9 - 1-2 SHIFT CONTROL VALVE AND SPRING
3 - 2-3 SHIFT VALVE AND SPRING 10 -

Page 1692 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual 3-4 ACCUMULATOR
(1) Position converter clutch valve and 3-4 shift
valve springs in housing (Fig. 324).
(2) Loosely attach accumulator housing with right-
side screw (Fig. 324). Install only one screw

Page 1693 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (19) Attach solenoid case connector to 3-4 accumu-
lator with shoulder-type screw. Connector has small
locating tang that fits in dimple at top of accumula-
tor housing (Fig. 328). Seat tang in dimple

Page 1701 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual NOTE: The 545RFE utilizes closed loop control of
pump line pressure. The pressure readings may
therefore vary greatly but should always follow line
pressure.
Some common pressures that can be measured