2002 JEEP GRAND CHEROKEE pressure testing

[x] Cancel search: pressure testing

Page 1597 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual GEARSHIFT CABLE
DIAGNOSIS AND TESTING - GEARSHIFT
CABLE
(1) The floor shifter lever and gate positions
should be in alignment with all transmission PARK,
NEUTRAL, and gear detent positions.
(2) Engine

Page 1653 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual TORQUE CONVERTER
DRAINBACK VALVE
DESCRIPTION
The drainback valve is located in the transmission
cooler outlet (pressure) line.
OPERATION
The valve prevents fluid from draining from the
converter into

Page 1685 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual Wipe the governor pressure sensor and solenoid
valve with dry, lint free shop towels only. The O-rings
on the sensor and solenoid valve are the only service-
able components. Be sure the vent ports in

Page 1696 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual AUTOMATIC TRANSMISSION - 545RFE
TABLE OF CONTENTS
page page
AUTOMATIC TRANSMISSION - 545RFE
DESCRIPTION........................178
OPERATION..........................179
DIAGNOSIS AND TESTING
DIAGNOSI

Page 1698 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual TRANSMISSION IDENTIFICATION
Transmission identification numbers are stamped
on the left side of the case just above the oil pan
sealing surface (Fig. 1). Refer to this information
when ordering replac

Page 1699 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual Diagnosis of these problems should always begin
by checking the easily accessible variables: fluid level
and condition, gearshift cable adjustment. Then per-
form a road test to determine if the probl

Page 1700 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual DIAGNOSIS AND TESTING - HYDRAULIC
PRESSURE TEST
An accurate tachometer and pressure test gauges
are required. Test Gauge C-3293-SP has a 300 psi
range and is used at all locations where pressures
exce

Page 1701 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual NOTE: The 545RFE utilizes closed loop control of
pump line pressure. The pressure readings may
therefore vary greatly but should always follow line
pressure.
Some common pressures that can be measured