ZKE - 39
WINDOW ANTI-TRAP DETECTION
The window anti-trap detection feature is only active in the one touch and convenience
close modes of operation. If the window switch is pushed/pulled and held, the Anti-trap
feature will not function.
The rubber pressure guard located at the top
edge of each door frame consists of two contact
strips that close when subjected to pressure.
This provides anti-trap detection and signal
generation to the GM.
When the contact strip closes, the window
immediately (10ms) reverses direction as with
previous anti-trap systems. The contact strip
does not require that the anti-trap feature be
initialized prior to operation.
The pressure sensor finger guard has a
resistance of 3.0 KOhm and it is monitored for
open circuit. When pressed, the monitored
resistance changes to <1KOhm. Faults with the
anti-trap system require that the window switch
be held to close the window.
CONVENIENCE OPENING/CLOSING
The GM and Front Door Switchblock Modules provide the convenience open/close feature
providing control of the power windows (and sunroof) from outside the vehicle with the key
in the driver’s door lock. The FZV provides the same function for the opening only.
• The anti-trap feature is active during convenience closing from the driver’s door lock.
• The convenience open feature provides outside activation of the windows and sunroof
in the same manner.
• If the GM receives a request to operate convenience close or open for more than 110
seconds, the function is deactivated and a fault code is stored.
• The Car Memory Feature can activate and deactivate the Convenience Open Feature
from the FZV’s control.
ZKE - 49
INTERIOR PROTECTION (UIS)
The UIS monitors the vehicle interior for motion through ultrasonic sound waves. The UIS
is a combined transmitter and receiver.
The X5 UIS sensor is incorporated into the
rear seat interior light trim cover. It is a two
piece unit with cable connection to the rear
transmitter/receiver.
The UIS and trim panel are clearly identified
with arrows indicating forward mounting
direction.
Due to the design of the vehicles interior,
the sensor is uni-directional and must be
installed in the proper direction to ensure
proper operation of the system (trim cover
ensures directional installation).
Every time the DWA system is armed (signal STDWA), the sensor adapts to what ever
objects might be stationary in the interior.
The sensor emits ultra sonic waves in a pro-
grammed timed cycle. It receives echos of
the emitted waves.
The UIS amplifies the received sound wave
signals and compares them with the trans-
mitted waves. The UIS also checks the
incoming echos for background hiss (wind
noise through a partially open window) and
adapts for this.
• If the echos are consistently similar, no movement is detected,
• If the echos are altered, (inconsistent), the UIS determines motion in the interior com-
partment.
If motion is detected, the UIS changes to a constant cycle and the echo is compared again.
If the inconsistency is still present the UIS sends the activate siren signal (INRS) to the GM.
As with the tilt sensor, the UIS is also switched OFF when the vehicle is locked two times
within ten seconds. This allows the sensor to be switched OFF for transportation purpos-
es.