2001 SUZUKI GRAND VITARA air condition

[x] Cancel search: air condition

Page 43 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-18 AIR CONDITIONING (OPTIONAL)
Terminal Wire CircuitMeasurement 
groundNormal value Condition
AC-B-2WHT/
BLKA/C evaporator 
temperature 
sensor (A/C 
evaporator ther-
mistor) inputGround to 
engine

Page 44 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-19
Refrigerant Recovery, Evacuation and Charging
Operation Procedure for Charging A/C with Refrigerant
WARNING:
Your eyes should not be exposed to refrigerant (liquid).

Page 45 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-20 AIR CONDITIONING (OPTIONAL)
Recovery
NOTE:
When discharging refrigerant out of A/C system,
always recover it by using refrigerant recovery and
recycling equipment (1). Discharging it into atmo-

Page 46 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-21
Evacuating
Evacuating procedure
1) Connect high charging hose (1) and low charging hose (2) of
manifold gauge set (3) respectively as follows: 
High Charging Hose (1)

Page 47 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-22 AIR CONDITIONING (OPTIONAL)
Checking system for pressure leaks
After completing the evacuation, close manifold gauge high pres-
sure valve (HI) and low-pressure valve (LO) and wait 10 minutes.
V

Page 48 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-23
The initial charging of the A/C system is performed from the high-
pressure side with the engine stopped.
And next, this method must be followed by charging from the

Page 49 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-24 AIR CONDITIONING (OPTIONAL)
c) Purge any air existing in center charging hose 
When using refrigerant container tap valve, use following
procedure to purge air.
i) Once fully tighten refrigerant

Page 50 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-25
On-Vehicle Service
Precaution
When servicing air conditioning system, the following rules must be observed.
Piping
When connecting hoses and pipes, apply a few drops