2001 INFINITI QX4 Blower

[x] Cancel search: Blower

Page 924 of 2395

INFINITI QX4 2001  Factory Service Manual 12 CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK©GO TO 13.
NG©Clean the rubber tube using

Page 925 of 2395

INFINITI QX4 2001  Factory Service Manual 14 CHECK EVAP CANISTER VENT CONTROL VALVE
With CONSULT-II
1. Perform ªVENT CONTROL/Vº in ªACTIVE TESTº mode.
2. Check air passage continuity and operation delay time under the following conditions

Page 926 of 2395

INFINITI QX4 2001  Factory Service Manual 16 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
INever apply force to the air hole protector of the sensor if

Page 932 of 2395

INFINITI QX4 2001  Factory Service Manual 8) Stop vehicle.
9) Select ªMODE 3º with GST.
IIf P0455 is displayed on the screen, go to ªDiagnostic
Procedureº, EC-397.
IIf P0440 or P1440 is displayed on the screen, go to ªDiagnos-
tic Proced

Page 934 of 2395

INFINITI QX4 2001  Factory Service Manual 6 CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
©GO TO 7.
7 CHECK EVAP CANISTER VENT CONTROL VALVE, O-RING AND CIRCUIT
Refer to ªDTC Confirmation Procedureº,

Page 1064 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0643
1 CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch ªOFFº.
2. Check for genuine NISSAN fuel filler cap design.
SEF915U
OK or NG
OK©GO TO 2.
NG©Replace with genuine

Page 1074 of 2395

INFINITI QX4 2001  Factory Service Manual 20 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
INever apply force to the air hole protector of the sensor if

Page 1084 of 2395

INFINITI QX4 2001  Factory Service Manual 9 CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK©GO TO 10.
NG©Clean the rubber tube using