6E2-14 ENGINE AND EMISSION CONTROL SYSTEM (SFI FOR G13)
IDLE SPEED / IDLE AIR CONTROL (IAC) DUTY
INSPECTION
Before idle speed / IAC duty check, make sure of the following.
Lead wires and hoses of Electronic Fuel Injection and engine
emission control systems are connected securely.
Accelerator cable has some play, that is, it is not tight.
Valve lash is checked and adjusted according to maintenance
schedule.
Ignition timing is within specification.
All accessories (wipers, heater, lights, A / C, etc.) are out of ser-
vice.
Air cleaner has been properly installed and is in good condition.
No abnormal air inhaling from air intake system.
After above items are all confirmed, check idle speed and IAC duty
as follows.
NOTE:
Before starting engine, place transmission gear shift lever in
“Neutral” (shift selector lever to “P” range for A / T vehicle),
and set parking brake and block drive wheels.
1) Connect SUZUKI scan tool (1) to DLC with ignition switch OFF,
if it is available.
2) Warm up engine to normal operating temperature.
3) Check engine idle speed and “IAC duty” as follow:
Select “Data List” mode on scan tool to check “IAC duty” and en-
gine speed.
Special Tool
(A): 09931-76011 (SUZUKI scan tool)
(B): Mass storage cartridge
(C): 09931-76030 (16 / 14 pin DLC cable)
If duty and/or idle speed is out of specifications, inspect idle air
control system referring to Diagnostic Flow Table B-4 IDLE AIR
CONTROL SYSTEM CHECK in Section 6.
ENGINE IDLE SPEED AND IAC DUTY
A/C OFFA/C ON
M / T vehicle750±50 r / min (rpm)875±50 r/minA / T vehicle
at P/N range750 ±50 r/min (rpm)
8 – 25 or *8 – 35%
875 ±50 r/min
(rpm)
NOTE:
Duty values with (*) are applicable to vehicle used at high
altitude (higher than 2,000 m or 6,560 ft).
4) Check that 875 ± 50 r / min. idle speed is obtained with lighting
switch ON and heater blower switch in 2 – 4 position.
If not, check “Electric load (+)” circuit and “Heater blower switch
signal” circuit referring to “ELECTRONIC CONTROL SYSTEM”
in this section and idle air control system.
5) Check that specified engine idle speed is obtained with A / C ON
if vehicle is equipped with A / C.
If not, check A / C ON signal circuit.
8G-14 IMMOBILIZER CONTROL SYSTEM
1. Main fuse
2. Main relay
3. ECM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler)For G10 engine
For G13B engine
For G10 engine For G13B engine
A-2 IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP DOSE NOT LIGHT AT IGNITION SWITCH ON)
STEPACTIONYESNO
11) Turn ignition switch ON.
Do other indicator / warning lights in
combination meter come ON?Go to Step 2.“IG” fuse blown, main fuse blown,
ignition switch malfunction,
“(d)” circuit between “IG” fuse
and combination meter or poor
coupler connection at
combination meter.
21) Turn ignition switch OFF and
disconnect connectors from ECM.
2) Check for proper connection to ECM
at terminal C02-18 for G10 engine or
C01-28 for G13B engine.
3) If OK, then using service wire, ground
terminal C02-18 for G10 engine or
C01-28 for G13B engine in connector
disconnected.
Does immobilizer indicator lamp turn on
at ignition switch ON?Substitute a known-
good ECM and
recheck.Bulb burned out or “(P)” wire
circuit open.
1
1. Ignition key with built-in transponder 1. Data link connector (DLC)
8G-16 IMMOBILIZER CONTROL SYSTEM
HOW TO REGISTER IGNITION KEY
Register the ignition key with a built-in transponder in Immobilizer
Control Module by using the following procedure.
1) Prepare Suzuki scan tool (TECH 1A kit and cartridge for immobi-
lizer control system).
2) With ignition switch OFF, connect Suzuki scan tool to data link
connector (DLC) located on underside of instrument panel at
driver’s seat side.
Special Tool
(A): 09931-76011 (Tech 1A)
(B): Immobilizer cartridge
(C): 09931-76030 (16 / 14-pin DLC cable)
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator’s manual.
3) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
4) Number of Transponder codes for ignition key with a built-in
transponder that can be registered in Immobilizer Control Mod-
ule is limited to 4. If needed, clear all Transponder codes for igni-
tion key with a built-in transponder that have been registered in
Immobilizer Control Module by executing the “CLR. TRANS
COD (CLEAR TP CODE)” command in the SELECT MODE
menu by using Suzuki scan tool.
NOTE:
When “CLR. TRANS COD (CLEAR TP CODE)” command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicles equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
5) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing “ENT. TRANS COD (ENT. TP
CODE)” command in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
IMMOBILIZER CONTROL SYSTEM 8G-17
7) If any other Transponder code for ignition key with a built-in
transponder needs to be registered, repeat above Steps 3), 5)
and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
PROCEDURE AFTER IMMOBILIZER
CONTROL MODULE REPLACEMENT
When Immobilizer Control Module was replaced, including when
replaced because rechecking by using a known-good Immobilizer
Control Module was necessary during trouble diagnosis, register
Transponder code and ECM / Immobilizer Control Module code in
Immobilizer Control Module and ECM / Immobilizer Control Module
code in ECM by performing following procedure.
1) Perform Steps 1) and 2) described in “How to register ignition
key” section.
2) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
3) Using Suzuki scan tool, clear all transponder codes registered
in Immobilizer Control Module by executing “CLR. TRANS COD
(CLEAR TP CODE)” command in SELECT MODE menu.
NOTE:
When “CLR. TRANS COD (CLEAR TP CODE)” command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicles equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
4) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing “ENT. TRANS COD (ENT. TP
CODE)” command in SELECT MODE menu.
5) Using Suzuki scan tool, register ECM / Immobilizer Control Mod-
ule code in both Immobilizer Control Module and ECM by
executing “RECORD ECU (RECORD ECM / PCM / ICM)” com-
mand in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
7) If any other Transponder code for ignition key with a built-in trans-
ponder needs to be registered, repeat above Steps 2), 4) and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
8G-18 IMMOBILIZER CONTROL SYSTEM
09931-76030
16 / 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)1. Storage case
2. Operator’s manual
3. Tech 1A
4. DLC cable
(14 / 26 pin, 09931-76040)
5. Test lead / probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version 1.5 or more
PROCEDURE AFTER ECM
REPLACEMENT
When ECM was replaced, including when replaced because re-
checking by using a known-good ECM was necessary during
trouble diagnosis, register ECM/Immobilizer Control Module code
in ECM by performing following procedure.
1) Perform Steps 1) and 2) described in “How to register ignition
key” section. And then turn ignition switch ON.
2) Using Suzuki scan tool, register ECM/Immobilizer Control Module
code in ECM by executing “RECORD ECU (RECORD ECM / Im-
mobilizer Control Module)” command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator’s manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS