YH4
GRAND
vol.1
0A
0B
1A
1B
3
3A
3B1
3C
3C1
3D
3E
3F
4A2
4B
5
6
7A5A
5B
5C
5E1
6A1
6A2
6A4
6B
6C
6E1
6E2
6F1
6F2
6G
6G1
6H
6K
7A1
7B1
7C1
7D
7E
7F
8
8B
8C
8D
8G
9
10
10A
8A
10B
6-1ENGINE
General Information and
Diagnosis (G16 / J20)
General Information and
Diagnosis (H25)
Engine Mechanical (G16)
Engine Mechanical (H25)
Engine Mechanical (J20)
Engine Cooling
Engine Fuel
Engine and Emission Control
System (SFI for G16 / J20)
Engine and Emission Control
System (SFI for H25)
Ignition System (G16)
Ignition System (J20 / H25)
Cranking System
(Reduction Type)
Cranking System
(No-Reduction Type)
Charging System
Exhaust System
TRANSMISSION, CLUTCH
AND DIFFERENTIAL
Manual Transmission (Type 1)
Manual Transmission (Type 2)
Automatic Transmission
Clutch (Hydraulic Type)
Transfer
Differential (Front)
Differential (Rear)
BODY ELECTRICAL SYSTEM
Wiring Diagram
Lighting System
Instrumentation / Driver
Information
Windows, Mirrors, Security
and Lock
Immobilizer Control System
BODY SERVICE
RESTRAINT SYSTEM
Seat Belt
Air Bag System GENERAL INFORMATION
General Information
Maintenance and Lubrication
TABLE OF CONTENTS TABLE OF CONTENTS SECTIONSECTION
0B
HEATING AND AIR
CONDITIONING
Heater and Ventilation
Air Conditioning
STEERING, SUSPENSION,
WHEELS AND TIRES
Front End Alignment
Power Steering (P / S) System
Steering Wheel and Column
(Not Equipped with Air Bag)
Air Bag Steering Wheel
and Column
Front Suspension
Rear Suspension
Wheel and Tires
1A
3A 0A
1B
3B1
3C
3C1
3D
3E
3F36A16
6A2
6A4
6B
6C
6E1
6E2
6F1
DRIVE SHAFT / PROP. SHAFT
Front Drive Shaft / Shaft
Bearing, Oil Seal
Propeller Shaft
BRAKES
Brake Pipe / Hose / Master
Cylinder
Front Brakes
Parking and Rear Brakes
Antilock Brake System
4A2
4B
5
5A
5B
5C
5E1
6F2
6G
6G1
6H
6K
7A
7A1
7B1
7C1
7D
7E
7F
8
8A
8B
8C
8D
8G
9
10
10A
10B
6-1
NOTE:
The screen toned Sections 6 ± 6K are included in Volume 2 and Section 8A is in Wiring
Diagram Manual.
YH4
GRAND
VITARA
1A
HEATER AND VENTILATION 1A-1
SECTION 1A
HEATER AND VENTILATION
WARNING:
For vehicles equipped with Supplement Restraint (Air Bag) System
Service on and around the air bag system components or wiring must be performed only by an autho-
rized SUZUKI dealer. Refer to ªAir Bag System Components and Wiring Location Viewº under ªGener-
al Descriptionº in air bag system section in order to confirm whether you are performing service on
or near the air bag system components or wiring. Please observe all WARNINGS and ªService Precau-
tionsº under ªOn-Vehicle Serviceº in air bag system section before performing service on or around
the air bag system components or wiring. Failure to follow WARNINGS could result in unintentional
activation of the system or could render the system inoperative. Either or these two conditions may
result in severe injury.
Technical service work must be started at least 90 seconds after the ignition switch is turned to the
ªLOCKº position and the negative cable is disconnected from the battery. Otherwise, the system may
be activated by reserve energy in the Sensing and Diagnostic Module (SDM).
NOTE:
The link mechanism of the heater varies depending on the specifications.
CONTENTS
GENERAL DESCRIPTION1A- 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Body Ventilation1A- 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DIAGNOSIS1A- 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis Table1A- 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Circuit1A- 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ON-VEHICLE SERVICE1A- 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Unit1A- 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor1A- 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor Relay1A- 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Motor Resistor1A- 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Mode Control Switch1A-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Mode Control Actuator1A-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Control Lever Assembly 1A-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Control Cables1A-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Unit1A-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rear Duct1A-19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-3
BODY VENTILATION
The body ventilation system of this vehicle has a fresh air intake located at the cowl top panel. When fresh air intake
control lever is at FRESH AIR position, ventilating air is drawn into the interior from the cowl center garnish and
drawn out from the ventilator outlet provided at each side body outer panel (both right and left side).
DIAGNOSIS
DIAGNOSIS TABLE
TroublePossible causeRemedy
Heater blower won't
work even when its
switch is ON.Blower fuse blown
Blower resistor faulty
Blower motor faulty
Wiring or grounding faultyReplace fuse to check for short.
Check resistor.
Replace motor.
Repair as necessary.
Incorrect temperature
output.Control cables broken or binding
Air damper broken
Air ducts clogged
Heater radiator leaking or clogged
Heater hoses leaking or cloggedCheck cables.
Repair damper.
Repair air ducts.
Replace radiator.
Replace hoses.
When mode control
switch is changed,
air outlet port is not
changed.Mode control switch faulty
Mode actuator faulty
Fuse blown
Wiring or grounding faulty
Air damper broken
Air ducts cloggedCheck and replace as necessary.
Check and replace as necessary.
Replace fuse to check for short.
Repair as necessary.
Repair damper.
Repair air ducts.
YH4
GRAND
VITARA
1A-4 HEATER AND VENTILATION
FOR LH VEHICLE
FOR RH VEHICLE
1. From ignition switch 1
2. From ignition switch 2
3. From blower fuse
4. Head light relay
5. To A / C controller6. Blower motor relay
7. Blower motor switch
8. Blower resistor
9. Blower motor
10. To ECM11. To illumination controller
(if equipped) or body ground
12. Mode control actuator
13. Mode control switch
14. From main fuse15. TAIL fuse 15 A
16. IG METER fuse 20 A
17. HEATER fuse 30 A
18. REAR DEFG fuse 15 A
19. Drive circuit
WIRING CIRCUIT
YH4
GRAND
VITARA
1. Blower motor switch connector
1
1A-14 HEATER AND VENTILATION
HEATER CONTROL LEVER ASSEMBLY
REMOVAL
1) Disconnect negative (±) cable at battery.
2) If equipped with air bag system, disable air bag system.
Refer to DISABLING AIR BAG SYSTEM in Section 10B.
3) Remove mode control switch. Refer to item HEATER MODE
CONTROL SWITCH in this section.
INSPECTION
Check heater blower motor switch for each terminal-to-terminal
continuity. For the detail refer to WIRING CIRCUIT earlier in this
section.
EFLMLMHH
LOW
M1
M2
HIGH
YH4
GRAND
VITARA
1A-18 HEATER AND VENTILATION
11) Remove heater core pipe clamps (1) and grommet (2).
12) Pull out heater core (1) from unit (2).
INSTALLATION
1) Install heater unit by reversing removal procedure, noting the
following items.
When installing each part, be careful not to catch any cable or
wiring harness.
When installing steering column assembly, refer to STEER-
ING COLUMN INSTALLATION in Section 3C or 3C1.
2) Install control cables. (Refer to HEATER CONTROL CABLES in
this section.)
3) Fill engine coolant to radiator.
4) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
5) Evacuate and charge system. Refer to items EVACUATING
SYSTEM and PROCEDURE OF CHARGING in Section 1B.
YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-7
ConditionPossible CauseCorrection
Cool air does not come
out or insufficient
cooling (A / C system
normal operative)Compressor faulty
Air in A / C system
Air leaking from cooling unit or air
duct
Heater and ventilation system faulty
Blower motor faulty
Excessive compressor oil existing in
A / C systemCheck compressor.
Replace condenser dryer, and
evacuation and charging.
Repair as necessary.
Check blower unit.
Check heater control lever assembly.
Check heater assembly.
Check blower motor.
Pull out compressor oil in A / C system
circuit, and replace compressor.
Cool air does not comes
out only intermittentlyWiring connection faulty
Expansion valve faulty
Excessive moisture in A / C system
A / C controller faulty
Magnetic clutch faulty
Excessive charge of refrigerantRepair as necessary.
Check expansion valve.
Replace condenser dryer, and
evacuation and charging.
Check A / C controller.
Check magnetic clutch.
Check charge of refrigerant.
Cool air comes out only
at high speedsCondenser clogged
Insufficient charge of refrigerant
Air in A / C system
Drive belt slipping
Compressor faultyCheck condenser.
Check charge of refrigerant.
Replace condenser dryer, and
evacuation and charging.
Adjust or replace drive belt.
Check compressor.
Cool air does not comes
out only at high speedsExcessive charge of refrigerant
A / C evaporator frostedCheck charge refrigerant.
Check A / C evaporator.
Check A / C thermistor.
Insufficient velocity of
cooled airA / C evaporator clogged or frosted
Air leaking from cooling unit or air
duct
Blower motor faulty
Wiring or grounding faultyCheck A / C evaporator.
Repair as necessary.
Check blower motor.
Repair as necessary.