YH4
GRAND
VITARA
7E-8 DIFFERENTIAL (FRONT)
1. ECM (PCM); viewed from harness side
Voltage Check [H25 engine model]
TER-
MINALCIRCUITWIRE
COLORNORMAL
VOLTAGECONDITION
C51 110 ± 14 VTransfer shift lever: 2H or NC51-1
-74WD Indicator lampOr / B0 ± 1 V4 seconds after transfer shift lever shifted
to 4H or 4L
C51 1Air pump assembly0 ± 1 VTransfer shift lever: 2H or NC51-1
-15(Pump motor and release
valve)R10 ± 14 V1 seconds after transfer shift lever shifted
to 4H or 4L
C51-14WD switchB/Or10 ± 14 VTransfer shift lever: 2H or N
-114WD switchB/Or0 ± 1 VTransfer shift lever: 4H or 4L
C51-3
-26GroundB/Bl0 ± 1 V±
C51-1Airpumpassembly0 ± 1 VTransfer shift lever: 2H or NC51-1
-18
Air um assembly
(pressure switch)P10 ± 14 V4 seconds after transfer shift lever shifted
to 4H or 4L
YH4
GRAND
VITARA
7E-10 DIFFERENTIAL (FRONT)
1. Plugged hose
2. Adjusting screw
3. Pipe (to air pump assembly)
4. Hose (to differential carrier)
5. Differential housing
4 5
INSPECTION
4WD Control System
1) Install special tool to air hose connecting between air pump as-
sembly and differential (actuator) as shown in figure. Tighten ad-
justing screw of special tool as far as it stops. Close air check
side opening by using fuel hose as blind plug.
Special Tool
(A): 09918-18110
(B): 09367-04002
NOTE:
Use care not to bend any part of hose.
2) Turn ON ignition switch and shift transfer lever from 2H to 4H
range.
3) Check that motor starts running (a sound can be heard) within
1 second and it stops when gauge of special tool indicates speci-
fied pressure value.
Check also for air leakage.
Pressure specification:
30.0 ± 45.0 kPa (0.30 ± 0.45 kg / cm
2, 4.25 ± 6.40 psi)
4) Check that pressure value indicated on gauge of special tool
drops as soon as transfer lever is shifted to 2H position.
5) Start motor by shifting transfer lever to 4H position again. Loos-
en adjusting screw to lower pressure value on gauge. Motor
should start to run again and stop in about 4 seconds.
6) With the adjusting screw of special tool loosened, shift transfer
shift lever to N or 2H position and then 4L or 4H position.
Pump motor should stop about 10 seconds after motor starts to
run.