Page 460 of 801

YH4
GRAND
VITARA
7B1-58 AUTOMATIC TRANSMISSION (4 A / T)
ENGINE BRAKE TEST
WARNING:
Before test, make sure that there is no vehicle behind so as
to prevent rear-end collision.
1) While driving vehicle in 3rd gear of ªDº range, shift select lever
down to ª2º range and check if engine brake operates.
2) In the same way as in step 1, check engine brake for operation
when select lever is shifted down to ªLº range.
3) If engine brake fails to operate in above tests, possible causes
for such failure are as follows. Check each part which is sus-
pected to be the cause.
Condition
Possible cause
Fails to operate when shifted
down to ª2º rangeSecond coast brake defec-
tive
Fails to operate when shifted
down to ªLº rangeReverse brake defective
ªPº RANGE TEST
1) Stop vehicle on a slope, shift select lever to ªPº range and at the
same time apply parking brake.
2) After stopping engine, depress brake pedal and release parking
brake.
3) Then, release brake pedal gradually and check that vehicle re-
mains stationary.
4) Depress brake pedal and shift select lever to ªNº range.
5) Then, release brake pedal gradually and check that vehicle
moves.
WARNING:
Before test, check to make sure no one is around vehicle
or down on a slope and keep watchful for safety during
test.
Page 461 of 801

YH4
GRAND
VITARA
1. Dipstick (G16 / J20)
2. Dipstick (H25)
AUTOMATIC TRANSMISSION (4 A / T) 7B1-59
ON-VEHICLE SERVICE
MAINTENANCE SERVICE
FLUID LEVEL
LEVEL CHECK AT NORMAL OPERATING TEMPERATURE
1) Stop vehicle and place it level.
2) Apply parking brake and place chocks against wheels.
3) With selector at P position, start engine.
4) Warm up engine till fluid temperature reaches normal operating
temperature (70 ± 80C / 158 ± 176F). As a guide to check fluid
temperature, warm up engine till engine coolant temperature
meter indicated around 1 unit above ªCº point.
5) Keep engine idling and shift selector slowly to L and back to P
position.
6) With engine idling, pull out dipstick, wipe it off with a clean cloth
and put it back into place.
7) Pull out dipstick again and check fluid level indicated on it. Fluid
level should be between FULL HOT and LOW HOT. If it is below
LOW HOT, add an equivalent of DEXRON-III up to FULL HOT.
Fluid specification
An equivalent of DEXRON-III
NOTE:
DO NOT RACE ENGINE while checking fluid level, even af-
ter the engine start.
DO NOT OVERFILL. Overfilling can causes foaming and
loss of fluid through breather. Then slippage and trans-
mission failure can result.
Bringing the level from LOW HOT to FULL HOT requires
0.3 liters (0.64/0.53 US/lmp.pt).
If vehicle was driven under high load such as pulling a
trailer, fluid level should be checked about half an hour af-
ter it is stopped.
Page 464 of 801

YH4
GRAND
VITARA
1. Manual selector assembly
(Select lever assembly)
2. Manual lever assembly
3. Select cable bracket
4. Select indicator
5. Slide cover
6. Select lever knob7. Spring
8. Knob button
9. Shift lock solenoid rod
10. Shift lock solenoid
11. Cover
12. Illumination lamp
13. Interlock cam
1. Interlock cam pin
(only for new selector assembly) Tightening Torque
(a): 18 N
.m (1.8 kg-m, 13.5 lb-ft)1. Manual lever
assembly
2. Select indicator
assembly
3. Illumination lamp
assembly
4. Bulb filter
5. Bulb
6. Knob assembly
7. Shift lock solenoid
Type-1 Type-2
Type-1
7B1-62 AUTOMATIC TRANSMISSION (4 A / T)
MANUAL SELECTOR ASSEMBLY
REMOVAL
1) Disconnect negative cable at battery.
2) Remove console box.
3) Disconnect connector for illumination lamp, shift lock solenoid
and overdrive OFF switch.
4) Disconnect interlock cable from interlock cam of selector as-
sembly.
5) Remove selector assembly mounting bolts.
6) Disconnect select cable from lever of selector assembly.
INSTALLATION
NOTE:
New selector assembly of Type-1 is supplied with held inter-
lock cam at interlock cable connecting position with pin. Re-
move this pin after connecting interlock cable to interlock cam
and tightening cable nut.
Reverse removal procedure to install noting the followings.
Connect interlock cable end to cam referring to steps 2) to 8) of
ªInterlock Cable Installationº section.
Upon completion of installation, confirm that brake (key) interlock
system operates properly.
Page 465 of 801

YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-63
1. Select lever assembly
2. Bolt
3. Select cable
4. Cable bracket
5. Bolt
6. Blank
7. Washer
8. Clip
9. Nut
10. Manual select lever
11. Lock washer
12. Nut
13. Select cable joint
14. Bush
15. Washer
16. E-ring
17. Transmission range switch assembly
18. Bolt
1. Transmission range
sensor (switch)
2. Select cable
3. Manual shift lever
4. Select cable joint
1. Select cable joint
A. Align with cable joint
B. Tighten with wrench
Tightening Torque
(a): 13 N.m (1.3 kg-m, 9.5 lb-ft)
(b): 7 N.m (0.7 kg-m, 5.5 lb-ft)
INSPECTION
Check select lever for smooth and clear-cut movement and position
indicator for correct indication.
For operation of select lever, refer to left figure.
SELECT CABLE
ADJUSTMENT
1) Before tightening cable end nut, shift select lever to ªNº.
2) Also shift manual shift lever to ªNº.
NOTE:
Make sure that nut and cable joint have clearance under
above conditions.
If select cable has been moved, push it in arrow C direc-
tion as shown in figure at the left till it stops and then con-
firm that select lever is in ªNº position.
3) Turn nut A by hand till it contacts manual select cable joint.
Then tighten nut B with wrench.
4) After select cable was installed, check for the following.
Push vehicle with select lever shifted to ªPº.
Vehicle should not move.
Vehicle can not be driven in ªNº.
Vehicle can be driven in ªDº, ª2º, and ªLº.
Vehicle can be backed in ªRº.
Page 466 of 801

YH4
GRAND
VITARA
7B1-64 AUTOMATIC TRANSMISSION (4 A / T)
1. A / T vehicle (output) speed sensor
ªNº reference
line
Center line on
manual valve shaft
G16 / J20
1. Service wire
2. PCM connectors disconnected
Switch
position
TRANSMISSION RANGE SWITCH (SENSOR)
INSPECTION & ADJUSTMENT
1) Shift select lever to ªNº range.
2) Check that center line on manual valve shaft and ªNº reference
line on switch are aligned. If not, loosen switch bolt and align
them.
3) Check that engine starts in ªNº and ªPº ranges but it doesn't start
in ªDº, ª2º, ªLº or ªRº range. Also, check that back-up lamp lights
in ªRº range.
4) If faulty condition cannot be corrected by adjustment, discon-
nect transmission range switch coupler and check that continu-
ity exists as shown by moving select lever.
Terminal No.54982310765498231076
P
R
N
D
2
L
A / T OUTPUT SPEED SENSOR
INSPECTION
Check A / T output speed sensor for resistance between terminals
of sensor or PCM coupler.
A / T output speed sensor
resistance value : 387 ± 473 at 20C, 68F
O / D CUT SWITCH
INSPECTION
Check O / D cut switch for operation referring to step 4 of Diag. Flow
Table B-2 in this section.
If malfunction is found, replace.
SOLENOID VALVES
(Shift solenoid valves & TCC solenoid valve)
INSPECTION
With couplers of PCM disconnected and using service wire as
shown at the left, check each solenoid valve for clicking sound.
G16 / J20 Engines
Shift solenoid valve - A (#1)C51-1-2
Shift solenoid valve - B (#2)C51-1-1
TCC (Lock-up) solenoid valveC51-1-8
Page 467 of 801

YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-65
1. Drain plug
2. Propeller shaft
1. Oiler (with transmission fluid)
2. Solenoid valve
3. BatteryA: Hole (Should be dry)
B: Exhausting fluid Terminal Arrangement of PCM Coupler
(Viewed from harness side)
WITH BATTERY VOLTAGE WITHOUT BATTERY VOLTAGE
H25 Engine
Shift solenoid valve ± A (#1)C51-1-6
Shift solenoid valve ± B (#2)C51-1-1
TCC (Lock-up) solenoid valveC51-1-2
REMOVAL
1) Pull out dipstick and lift up vehicle.
2) With engine cooled, remove drain plug from oil pan and drain
A / T fluid.
3) Install drain plug with gasket.
Tightening Torque
(a): 23 N
.m (2.3 kg-m, 17.0 lb-ft)
4) Remove exhaust pipe bracket and disconnect front propeller
shaft from front differential (if equipped).
5) Remove oil pan bolts.
6) Remove oil pan.
7) Remove oil tubes.
8) Remove solenoid valve No.1 (shift solenoid valve A and B) or so-
lenoid valve No.2 (TCC solenoid valve).
OPERATION CHECK
Whenever shift solenoid valves and TCC (lock-up) solenoid valve
are removed from transmission, verify their valve function physical-
ly before they are reinstalled.
1) Apply oiler to solenoid valve and give compression by hands
and then check to be sure that transmission fluid from oiler does
not come out of holes in solenoid valve when battery voltage is
not conducted.
2) Under the same conditions as above, conduct battery voltage
and then make sure that fluid comes out with vigor.
NOTE:
If fluid does not come out with vigor in above step 2 in-
spection, do not re-use that solenoid valve.
Figure at the left shows shift solenoid valve check.
Check TCC solenoid valve also in the same way.
Page 468 of 801
YH4
GRAND
VITARA
7B1-66 AUTOMATIC TRANSMISSION (4 A / T)
14
2
3
INSTALLATION
Reverse removal procedure to install solenoid valves and noting
the following points.
For details of solenoid valve installation, refer to ªUnit Repairº
section. Use new gasket and O-ring.
Install oil tubes in such order as shown in figure.
For details of oil pan installation, refer to ªUnit Repairº section.
Use new oil pan gasket.
Tighten universal joint flange bolts & nuts and exhaust pipe brack-
et bolts to specified torque.
Fill A / T fluid and check fluid level according to procedure de-
scribed in ªCHANGING FLUIDº previously.
Check for fluid leakage after warming up A / T.
THROTTLE POSITION SENSOR
INSPECTION
Refer to SECTION 6E1 / 6E2 for inspection.
POWER / NORMAL CHANGE SWITCH
INSPECTION
Check Power / Normal change switch for operation referring to Step
4 of Diag. Flow Table B-4 in this section.
If malfunction is found, replace.
Page 469 of 801
YH4
GRAND
VITARA
AUTOMATIC TRANSMISSION (4 A / T) 7B1-67
1. Oil cooler pipes
2. Union gaskets
3. Pipe bolt
OIL COOLER PIPES
REMOVAL
1) Lift up vehicle.
2) Make sure to wash dirt off from around pipe joints.
3) With engine is cool, loosen oil cooler pipe union bolts with oil out-
let union locked and remove oil cooler pipes from oil outlet
unions and hoses.
NOTE:
To avoid fluid leakage, plug open ends of oil outlet unions
and hoses right after they are disconnected.
INSTALLATION
1) Use new union gaskets and connect oil cooler pipes to oil outlet
unions.
2) Connect hoses to pipes and clamp them securely.
3) Tighten union bolts to specified torque with oil outlet union
locked.
Tightening Torque
(a): 35 N
.m (3.5 kg-m, 25.5 lb-ft)
4) Tighten pipe bolt securely.
5) Check A / T fluid level according to procedure described in ªFluid
Levelº section.
Add if necessary.
6) Check for fluid leakage after warming up A / T.