Page 202 of 1111
± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
BE±163
2464 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
Start registration of recognition code
The vehicle should be in the following conditions.
Any door is OPEN. (Other doors are CLOSED)
Any door is UNLOCKED.
Insert the key into the ignition key cylinder, then pull it out.
Press the door lock control switch (for manual operation) 5 times to
LOCK/UNLOCK at approx. 1 sec. interval.
1st time 2nd time 3rd time 4th time 5th time
LOCK
OFF
UNLOCK
Approx.
1 sec.Approx.
1 sec.
Close the all door, then open the any door.
Again press the door lock control switch (for manual operation) 5 times to
LOCK/UNLOCK at approx. 1 sec. interval.
1st time 2nd time 3rd time 4th time 5th time
LOCK
OFF
UNLOCK
Approx.
1 sec.Approx.
1 sec.
Insert the key into the ignition key cylinder.
Within
40 secs.
Within
40 secs.
Page 203 of 1111

BE±164
± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
2465 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
Within
3 secs.
Turn the ignition switch from ON to LOCK at approx. 1 sec. interval 1 to 5 times to select the mode.
Pull out the key plate from the ignition key cylinder.
When add mode or rewrite mode
is selected.When confirmation
mode is selected.
ON
ONON
LOCK
LOCKLOCK
Approx.
1 sec.Approx.
1 sec. Approx. 1 sec.Approx.
1 sec.Approx.
1 sec.
Add mode
Rewrite modeConfirmation mode
ON ± LOCK change occurs 1 time
ON ± LOCK change occurs 2 timesON ± LOCK change occurs 3 times
MPX body ECU automatically performs
the LOCK±UNLOCK operation once
or twice at 1 sec. interval to iniform the
operator that either the add mode or
rewrite mode has been selected.
LOCK±UNLOCK occurs once
LOCK±UNLOCK occurs twice
Indicates that add mode has been selected.
Indicates that rewrite mode has been
selected.
1 sec.
LOCK
1 sec.1 sec.
LOCK
UNLOCK
UNLOCK
LOCK
2 secs.2 secs.
UNLOCK MPX body ECU automatically performs the
LOCK±UNLOCK operation 1 to 4 times at
2 sec. interval to inform the operator of
the number of the registered codes.
HINT:
When the number of the registered code
is 0, the operation is automatically
performed 5 times.
Example:
When the operation is performed twice, it
directs that 2 types of recognition code
have been registered.
1st time 2nd time
Registration of recognition code (Confirmation
mode and prohibition mode) is completed.
ON
LOCK
Approx.
1 sec.Approx.
1 sec.
Prohibition mode
ON ± LOCK change occurs 5 times
When prohibition
mode is selected.
Page 204 of 1111

± BODY ELECTRICALWIRELESS DOOR LOCK CONTROL SYSTEM
BE±165
2466 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
MPX body performs LOCK±UNLOCK operation 5 times at a 1 sec.
interval to inform the operator that prohibition mode has been selected.
Press again either one of 3 switches on the transmitter for more than 1 sec.
MPX body ECU automatically performs LOCK±UNLOCK operation once or
twice at a 1 sec. interval to inform the operator that the receiver has received the
signal from the transmitter.
LOCK±UNLOCK occurs once
LOCK±UNLOCK occurs twice Registration of recognition code is completed
Registration of recognition code has not been completed.
Recognition code received first time and second time did not match.
Proceed to continue registration
If even one of the following conditions is satisfied, registration of recognition
codes is completed.
40 secs. elapses since the MPX body ECU response.
The driver's door is closed.
The key plate is inserted in the ignition key cylinder.
4 type recognition codes are registration at one time.
Registration of recognition codes (add mode or rewrite mode) is completed.
Within
3 secs.Within
40 secs.
ON
LOCK
Approx.
1 sec.Approx.
1 sec.
When prohibition
mode is selected.
Press the lock and unlock switches on the transmitter simultaneously within 1 sec.
If LOCK±UNLOCK operation can not be performed at all, the mode returns to the
normal mode, then start with ºStart registration of recognition codeº.
Proceed to finish registration
Within 40 secs.
Page 214 of 1111
BE02J±10
I01368
Mirror Assembly
Mirror Motor
Mirror Switch
Left/Right Adjustment Switch
Mirror Control SwitchIgnition Switch
Driver Side Junction Block
Body ECU No.2
± BODY ELECTRICALPOWER MIRROR CONTROL SYSTEM
BE±175
2476 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
POWER MIRROR CONTROL SYSTEM
LOCATION
Page 221 of 1111

BE0HD±04
I05186
ºBrightº ºDarkº1
2
3
4
Black coloured tape
I04048
Wire Harnes Side BE±182
± BODY ELECTRICALELECTRO CHROMIC MIRROR SYSTEM
2483 Author: Date:
2000 LEXUS GS300/GS400 (RM718U)
INSPECTION
1. INSPECT ELECTRO CHROMIC INNER MIRROR OP-
ERATION
(a) Connect the positive (+) lead from the battery to terminal
1 and the negative (±) lead to terminal 4.
(b) Connect the positive (+) lead from the voltmeter to termi-
nal 2 and the negative (±) lead to terminal 3.
(c) Attach a black coloured tape to forward sensor to prevent
it from sensing.
(d) When the mode is turned to AUTO, check that indicator
light lights up.
(e) Light up the mirror with an electric light, and check that
there is battery positive voltage and mirror surface
changes ºbrightº to ºdarkº.
If operation is not as specified, replace the inner mirror.
2. INSPECT ELECTRO CHROMIC INNER MIRROR CIR-
CUIT
Disconnect the connector from the mirror and inspect the con-
nector on the wire harness side, as shown.
Tester connectionConditionSpecified condition
4 ± GroundConstantContinuity
1 ± GroundIgnition switch LOCK or ACCNo voltage
1 ± GroundIgnition switch ONBattery positive voltage
If circuit is not as specified, inspect the circuits connected to
other parts.
Page 223 of 1111