2000 HONDA CIVIC air condition

[x] Cancel search: air condition

Page 1451 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Recovery
Use only service equipment that is U.L.-listed and is cer-
tified to meet the requirements of SAE J2210 to remove
HFC-134a (R-134a) from the air conditioner system
CAUTION: Exposure to air co

Page 1454 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Compressor (SANDENI
Replacement
1.lf the compressor is marginally operable, run the
engine at idle speed, and let the air conditioner
work for a few minutes. then shut the engine off.
Disconnect the n

Page 1461 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Compressor (DENSO)
Replacement
1.lf the compressor is marginally operable, run the
engine at idle speed, and let the air conditioning work
for a few minutes, then shut the engine off
Disconnect the ne

Page 1469 of 2189

HONDA CIVIC 2000 6.G Workshop Manual A/C System Service
Evacuation
Use only service equipment that is U L.-listed and is cer-
tified to meet the requirements oJ SAE J2210 to remove
HFC-134a (R-134a) from the air conditioner system
CAUTI

Page 1470 of 2189

HONDA CIVIC 2000 6.G Workshop Manual A/C System Service
Charging
Use only service equipment that is U.L.-listed and is cer-
tified to meet the requirements of SAE J2210 to remove
HFC-134a (R-134a) from the air conditioner system.
CAUTION

Page 1471 of 2189

HONDA CIVIC 2000 6.G Workshop Manual lf .
Electrical
Special Toofs .,....................,23-2
Troubleshooting
Tips and Precautions ..............,.................... . 23-3
Five-step Troubleshooting .............. ......... . . 23-5
w

Page 1575 of 2189

HONDA CIVIC 2000 6.G Workshop Manual -lgnition Timing Inspection and Setting
1.Check the idle speed, and adjust it it necessary (see
section l 1 ).
Pull out the service check connector 2P (BRN and BLK
wires) from the connector holder l

Page 1616 of 2189

HONDA CIVIC 2000 6.G Workshop Manual Interlock System
Control Unit Input Test
1. Disconnect the 8P connector from the interlock con-trol unit.
2. Inspect the connector and socket terminals to besure they are all making good contact.. lf