01-133
Read Measuring Value Block (scan tool
function 08)
Carrying out "Read Measuring Value Block"
function 08
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -8- to select "Read Measuring Value Block"
function 08.
Rapid data transfer
Q
08 - Read Measurin
g Value Block
Indicated on display
- Press -Q- button to confirm input.
Read Measuring Value BlockInput displa
y group number XXX
Indicated on display
The selected measuring value block is now indicated in standard format.
Evaluation page 01
-134
. - Press buttons -0-, -0- and -1- to input display group number 1 (001).
- Press -Q- button to confirm input.
Pa
ge 36 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
01-134
Read Measuring Value Block, overview
Display group 001
Indicated on Display
Display value
Identification
Read Measuring Value Block 1 0100 1) 1 = switch positions
1 2 3 4
100% 1) 2 = sensitivity of the sensors
3 = not assigned
4 = not assigned 1) Example of display.
Display value table
1
2
Switch for Int. Monitoring:
Driver-side door contact switch
Anti-theft warning system:
Glass breakage system 2): : pressed = 1, not pressed = 0
: driver-side door open = 1, driver-side door closed = 0
: armed = 1, not armed = 0
: present = 1, not present = 0 50 ... 100% 3)
2) Avant only. 3) Refer to "Adaptation" function 10 page 01
-135
.
Pa
ge 37 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4