Page 27 of 38
24-115
- Press buttons -0- and -6- to select "End Output"
function 06, and press -Q- button to confirm
input.
- Switch ignition off.
Note:
The values displayed in display field 3 depend on
the calibration of the Throttle Position (TP)
sensor and do not correspond with the actual
throttle valve opening in degrees. The maximum
displayed value is 90.0 . If the throttle angle value does not increase
uniformly:
- Replace throttle valve control module -J338-.
- Carry out adaptation of throttle valve control
module to ECM Page 24
-119
.
- Check readiness code Page 01
-59
. If
Diagnostic Trouble Code (DTC) memory has
been erased, or ECM was disconnected,
generate new readiness code Page 01
-62
.
Evaluating display group 3
Pa
ge 27 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 35 of 38

24-120
Test procedure
- Connect VAG 1551 or VAG 1552 scan tool and
press buttons -0- and -1- to insert "Engine
Electronics" address word 01 (with ignition
switched on; engine not running) Page 01
-7 .
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -4- to select "Basic Setting" function 04, and
press -Q- button to confirm input.
System in Basic Settin
g
HELP
Input displa
y group number XXX
Indicated on display
- Press buttons -0-, -6- and -0- to input display group number 60, and
press -Q- button to confirm input.
System in Basic Setting 60 1 2 3 4
Indicated on display (1-4 display fields)
Note:
After confirming input of display group 60, adaptation is started. The
Throttle Position (TP)sensor is positioned in the closed throttle, wide
open throttle and limp-home positions. Following this procedure, other
intermediate steps will create a characteristic curve of the relationship
between Throttle Position (TP) sensor -G69- and angle sensor for
throttle drive -G187-. The Motronic ECM stores these values in permanent memory.
Afterward, the throttle valve assumes the starting position.
Pa
ge 35 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2
Page 38 of 38
24-122
If displayed values are OK:
- Allow at least 30 seconds.
- End adaptation as soon as possible after 30
seconds by pressing button.
- Press buttons -0- and -6- to select "End Output"
function 06, and press -Q- button to confirm
input.
Pa
ge 38 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2