YH4
GRAND
VITARA
GENERAL INFORMATION 0A-9
When disconnecting vacuum hoses, attach a tag describing
the correct installation positions so that the hoses can be re-
installed correctly.
After servicing fuel, oil, coolant, vacuum, exhaust or brake
systems, check all lines related to the system for leaks.
For vehicles equipped with fuel injection systems, never dis-
connect the fuel line between the fuel pump and injector
without first releasing the fuel pressure, or fuel can be
sprayed out under pressure.
PRECAUTIONS FOR CATALYTIC CONVERTER
For vehicles equipped with a catalytic converter, use only un-
leaded gasoline and be careful not to let a large amount of un-
burned gasoline enter the converter or it can be damaged.
± Conduct a spark jump test only when necessary, make it as
short as possible, and do not open the throttle.
± Conduct engine compression checks within the shortest
possible time.
± Avoid situations which can result in engine misfire (e.g.
starting the engine when the fuel tank is nearly empty).
YH4
GRAND
VITARA
0B-4 MAINTENANCE AND LUBRICATION
MAINTENANCE RECOMMENDED UNDER SEVERE DRIVING CONDITIONS
If the vehicle is usually used under the conditions corresponding to any severe condition code given below, it is
recommended that applicable maintenance operation be performed at the particular interval as given in the chart
below.
Severe condition code
A ± Repeated short trips E ± Repeated short trips in extremely
B ± Driving on rough and / or muddy roads cold weather
C ± Driving on dusty roads F ± Leaded fuel use
D ± Driving in extremely cold weather G ± ± ± ± ± ± ± ± ±
and / or salted roads H ± Trailer towing (if admitted)
Severe
Condition Code
MaintenanceMaintenance
OperationMaintenance Interval
BCDITEM 1-1IEvery 15,000 km
(9,000 miles) or 12 months
± B C D ± ± ± ±Drive belt (V-rib belt)REvery 45,000 km
(27,000 miles) or 36 months
A ± C D E F ± HITEM 1-4
Engine oil and oil filterREvery 5,000 km
(3,000 miles) or 4 months
± B ± ± ± ± ± ±ITEM 1-6
Exhaust pipe mountingsIEvery 15,000 km
(9,000 miles) or 12 months
CITEM 3-1IEvery 2,500 km
(1,500 miles)
± ± C ± ± ± ± ±Air cleaner filter*1REvery 30,000 km
(18,000 miles) or 24 months
ABC EF HITEM 2-1Nickel plugREvery 10,000 km
(6,000 miles) or 8 months
A B C ± E F ± HSpark plugsIridium plugREvery 30,000 km
(18,000 miles) or 24 months
± B ± D E ± ± HITEM 6-9
Propeller shafts and drive shaftsIEvery 15,000 km
(9,000 miles) or 12 months
± B ± ± E ± ± H
ITEM 6-10, 6-12, 6-13
Manual transmission,
transfer and differential oil
REvery 30,000 km
(18,000 miles) or 24 months
± B ± ± E ± ± HITEM 6-11
Automatic transmission fluidREvery 30,000 km
(18,000 miles) or 24 months
± B ± ± ± ± ± ±ITEM 6-8
Suspension bolts and nutsTEvery 15,000 km
(9,000 miles) or 12 months
± B C D ± ± ± HITEM 6-7
Wheel bearingIEvery 15,000 km
(9,000 miles) or 12 months
CD
ITEM 6-17
Air conditioning filter*2
IEvery 15,000 km
(9,000 miles) or 12 months
± ± C D ± ± ± ±Air conditioning filter 2
(if equipped)REvery 45,000 km
(27,000 miles) or 36 months
NOTES:
ªIº : Inspect and correct, replace or lubricate if necessary
ªRº : Replace or change
ªTº : Tighten to the specified torque
*1 : Inspect or replace more frequently if necessary.
*2 : Clean or replace more frequently if the air from the air conditioning decreases.
YH4
GRAND
VITARA
2
1. Oil filter
2. Oil filter wrench
MAINTENANCE AND LUBRICATION 0B-9
3) Loosen oil filter by using oil filter wrench (special tool).
Special Tool
(A): 09915-47310 (H25 engine)
09915-47330 (G16 and J20 engines)
NOTE:
Before fitting new oil filter, be sure to oil its O-ring. Use engine
oil for this purpose.
4) Screw new filter on oil filter stand by hand until the filter O-ring
contacts the mounting surface.
CAUTION:
To tighten oil filter properly, it is important to accurately
identify the position at which at filter O-ring first contacts
the mounting surface.
5) Tighten the filter 3 / 4 turn from the point of contact with the
mounting surface using an oil filter wrench.
Tightening Torque (Reference)
(b): 14 N
.m (1.4 kg-m, 10.5 lb-ft)
6) Replenish oil until oil level is brought to FULL level mark on dip-
stick. (oil pan and oil filter capacity). The filler inlet is at the top
of the cylinder head cover.
It is recommended to use engine oil of SG, SH or SJ grade.
NOTE:
For temperature between ±20C (±4F) and 30C (86F), it
is highly recommended to use SAE 10W ± 30 oil.
G16 EngineJ20 EngineH25 Engine
Oil pan capacityAbout 4.0 liters
(10.6 / 8.8 US / Imp pt.)About 5.0 liters
(10.6 / 8.8 US / Imp pt.)
Oil filter capacityAbout 0.2 liters
(0.4 / 0.3 US / Imp pt.)About 0.5 liters
(1.1 / 0.9 US / Imp pt.)
OthersAbout 0.3 liters
(0.6 / 0.5 US / Imp pt.)About 0.4 liters
(1.1 / 0.9 US / Imp pt.)About 0.7 liters
(1.5 / 1.2 US / Imp pt.)
TotalAbout 4.5 liters
(9.5 / 7.9 US / Imp pt.)About 5.6 liters
(11.8 / 9.8 US / Imp pt.)About 6.2 liters
(13.1 / 10.9 US / Imp pt.)
YH4
GRAND
VITARA
1. Full level mark (hole)
2. Low level mark (hole)
0B-10 MAINTENANCE AND LUBRICATION
NOTE:
Engine oil capacity is specified. However, note that the
amount of oil required when actually changing oil may
somewhat differ from the data in the table depending on
various conditions (temperature, viscosity, etc.).
7) Check oil filter and drain plug for oil leakage.
8) Start engine and run it for three minutes. Stop it and wait five min-
utes before checking oil level. Add oil, as necessary, to bring oil
level to FULL level mark on dipstick.
NOTE:
Step 1) ± 7) outlined above must be performed with ENGINE
NOT RUNNING. For step 8), be sure to have adequate ven-
tilation while engine is running.
ITEM 1-5
Engine Coolant Change
WARNING:
To help avoid danger of being burned, do not remove radia-
tor cap while engine and radiator are still hot. Scalding fluid
and steam can be blown out under pressure if cap is taken
off too soon.
1) Remove radiator cap when engine is cool.
2) Loosen radiator drain plug to drain coolant.
3) Remove reservoir, which is on the side of radiator, and drain.
4) Tighten plug securely. Also reinstall reservoir.
5) Fill radiator with specified amount of coolant, and run engine for
2 or 3 minutes at idle. This drives out any air which may still be
trapped within cooling system. STOP ENGINE. Add coolant as
necessary until coolant level reaches the filler throat of radiator.
Reinstall radiator cap.
YH4
GRAND
VITARA
MAINTENANCE AND LUBRICATION 0B-11
1. Reservoir
2. FULL level mark
3. LOW level mark
4. Arrow mark
5. Reservoir cap
546) Add coolant to reservoir so that its level aligns with Full mark.
Then, reinstall cap aligning arrow marks on reservoir and cap.
NOTE:
When installing reservoir cap, align arrow marks on reser-
voir and cap.
CAUTION:
When changing engine coolant, use mixture of 50% wa-
ter and 50% ANTIFREEZE / ANTICORROSION COOLANT
for the market where ambient temperature falls lower
than ±16C (3F) in winter, and mixture of 70% water and
30% ANTIFREEZE / ANTICORROSION COOLANT for the
market where ambient temperature doesn't fall lower
than ±16C (3F).
Even in a market where no freezing temperature is antici-
pated, mixture of 70% water and 30% ANTIFREEZE / AN-
TICORROSION COOLANT should be used for the pur-
pose of corrosion protection and lubrication.
ITEM 1-6
Exhaust System Inspection
WARING:
To avoid danger of being burned, do not touch exhaust sys-
tem when it is still hot. Any service on exhaust system
should be performed when it is cool.
When carrying out periodic maintenance, or the vehicle is raised for
other service, check exhaust system as follows:
Check rubber mountings for damage, deterioration, and out of
position.
Check exhaust system for leakage, loose connections, dents and
damages.
If bolts or nuts are loose, tighten them to specification.
Check nearby body areas for damaged, missing, or misposi-
tioned parts, open seams, holes, loose connections or other de-
fects which could permit exhaust fumes to seep into the vehicle.
Make sure that exhaust system components have enough clear-
ance from the underbody to avoid overheating and possible dam-
age to the floor carpet.
Any defects should be fixed at once.
YH4
GRAND
VITARA
1B-8 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS OF ABNORMAL NOISE
There are various types of noise, ranging from those produced in the engine compartment to those from the pas-
senger compartment, also from rumbling noises to whistling noises.
ABNORMAL NOISE FROM COMPRESSOR
ConditionPossible CauseCorrection
During compressor operation, a
rumbling noise is heard
proportional to engine
revolutions.Inadequate clearance in piston
area (piston or swash-plate).Repair or replace compressor as
necessary.
A loud noise is heard at a certain
rpm, disproportionately to engine
revolution.Loose or faulty V-belt.
Loose mounting bolts.Adjust V-belt tension, or
replace belt.
Retighten mounting bolts.
A loud rattle is heard at low
engine rpm.Loose compressor center bolt.Retighten center bolt.
Replace compressor if it was
operated in this condition for a
long time.
ABNORMAL NOISE FROM MAGNETIC CLUTCH
ConditionPossible CauseCorrection
A rumbling noise is heard when
compressor is not operating.Worn or damaged bearings.Replace bearings.
A chattering noise is heard when
compressor is engaged.Faulty clutch gap (excessive).
Worn clutch friction surface.
Compressor oil leaked from shaft
seal, contaminating the friction
surface.Adjust clutch gap.
Replace clutch.
Replace compressor shaft oil
seal.
ABNORMAL NOISE FROM TUBING
ConditionPossible CauseCorrection
A droning noise is heard inside
vehicle, but not particularly
noticeable in engine
compartment.Faulty tubing clamps.
Resonance caused by pulsation
from variations in refrigerant
pressure.Reposition clamps or increase
the number of clamps.
Attach a silencer to tubing, or
modify its position and length.
ABNORMAL NOISE FROM CONDENSER
ConditionPossible CauseCorrection
Considerable vibration in
condenser.Resonance from condenser
mounting stay and body.Firmly insert a silencer between
condenser mounting stay and
body.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-9
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
ConditionPossible CauseCorrection
A large rattling noise is heard at
idle or sudden acceleration.Loosen pulley mounting bolt.
Worn or broken bearings.Retighten bolt.
Replace bearings.
ABNORMAL NOISE FROM TENSION PULLEY
ConditionPossible CauseCorrection
Clattering noise is heard from
pulley.
Pulley cranks upon contact.Worn or damaged bearings.
Cracked or loose bracket.Replace bearings.
Replace or retighten bracket.
ABNORMAL NOISE FROM EVAPORATOR
ConditionPossible CauseCorrection
Whistling sound is heard from
evaporator.Depending on the combination of
the interior / exterior
temperatures, engine rpm and
refrigerant pressure, the
refrigerant flowing out of the
expansion valve may, under
certain conditions, make a
whistling sound.At times, slightly decreasing
refrigerant volume may stop this
noise.
Inspect expansion valve and
replace if faulty.
ABNORMAL NOISE FROM BLOWER MOTOR
ConditionPossible CauseCorrection
Blower motor emits a chirping
sound in proportion to its speed of
rotation.
Fluttering noise or large droning
noise is heard from blower motor.Worn or damaged motor brushes
or commutator.
Leaves or other debris
introduced from fresh air inlet to
blower motor.Repair or replace blower motor.
Remove debris and make sure
that the screen at fresh air inlet is
intact.
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-15
AMBIENT TEMPERATURE WITHIN 30 ± 35C (85 ± 95F)
CONDITION
MANIFOLD
GAUGEMPa
(kg/cm2)
(psi)DETAILCAUSECORRECTION
LoHi
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Normal condition.ÐÐÐÐ
Negative
pressure0.5 ± 0.6
(5 ± 6)
(71.2 ± 85.3)
The low pressure side
reads a negative pressure,
and the high pressure side
reads an extremely low
pressure.
Presence of frost around
tubing to and from receiver /
dryer and expansion valve. Dust particles or water
droplets are either stuck or
frozen inside expansion
valve, preventing the
refrigerant from flowing.Clean expansion valve.
Replace it if it cannot be
cleaned.
Replace receiver / dryer.
Evacuate the A / C
system and recharge
with fresh refrigerant.
Normal:
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)
Abnormal:
Negative
pressureNormal:
1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Abnormal:
0.69 ± 0.98
(7 ± 10)
(100 ± 142) During A / C operation, the
low pressure side
sometimes indicates
negative pressure, and
sometimes normal
pressure. Also high
pressure side reading
fluctuates between the
abnormal and normal
pressure.Expansion valve is frozen
due to moisture in the
system, and temporarily
shuts off the refrigeration
cycle.Replace expansion
valve.
Replace receiver / dryer.
Evacuate A / C system
and recharge with fresh
refrigerant.
0.05 ± 0.15
(0.5 ± 1.5)
(4.2 ± 21.3)
0.69 ± 0.98
(7 ± 10)
(100 ± 142)
Both low and high pressure
sides indicate low readings.
Continuous air bubbles are
visible through sight glass.
Output air is slightly cold.Insufficient refrigerant in
system. (Refrigerant
leaking)Using a gas leak
detector, check for leaks
and repair as necessary.
Recharge refrigerant to a
specified amount.
If the pressure reading is
almost 0 when the
manifold gauges are
attached, check for any
leaks, repair them, and
evacuate the system.
0.4 ± 0.6
(4 ± 6)
(56.9 ± 85.3)
Pressure on low pressure
side is high.
Pressure on high pressure
side is low.
Both pressure becoming
equal right after A / C is
turned OFF.Internal leak in compressor.Inspect compressor and
repair or replace as
necessary.
035 045
High pressure reading on
both low and high pressure
sides.
Air bubbles are not visible
even when engine rpm is
lowered.Overcharged A / C system.
Faulty condenser cooling
operation.
Faulty condenser fan
operation.Adjust refrigerant to
specified amount.
Clean condenser.
Inspect and repair
condenser fan.
0.35 ± 0.45(3.5 ± 4.5)
(50 ± 64)
1.96 ± 2.45
(20 ± 25)
(285 ± 355)
High pressure reading on
both low and high pressure
sides.
Low pressure side tubing is
not cold when touched.
Air bubbles are visible
through sight glass.Presence of air in A / C
system. (Improperly
evacuated)Replace receiver / dryer.
Inspect quantity of
compressor oil and
presence of
contaminants in oil.
Evacuate system and
recharge with fresh
refrigerant.
0.45 ± 0.55
(4.5 ± 5.5)
(64 ± 78)
High pressure reading on
both low and high pressure
sides.
Large amount of frost or
dew on the low pressure
side tubing.Faulty expansion valve.
Refrigerant flow is not
regulated properly.Replace expansion
valve.