1999 HONDA CIVIC ect

[x] Cancel search: ect

Page 630 of 2189

HONDA CIVIC 1999 6.G Workshop Manual Transmission Assembly
Removal(contd)
14. Remove the driveshafts and the intermediate shaft(see section 16).
NOTE: Coat all precision the finished surfaces with
clean engine oil or grease. Tie plastic

Page 632 of 2189

HONDA CIVIC 1999 6.G Workshop Manual Transmission Assembly
lnstallation
Install the transmission assembly in the reverse order of
removal.
. Before installing, check that the two dowel pins are
installed in the clutch housing.
. When ins

Page 633 of 2189

HONDA CIVIC 1999 6.G Workshop Manual . Apply grease to the slave cylinder push rod.
NOTE: Use only Super High Temp Urea Grease
(P/N 08798 - 9002).
6x1.0mm9.8 Nm (1.0 kgl m,
7.2 tbl.ft)
-6,4- 9m2)
Refillthe transmission with oil (see pag

Page 634 of 2189

HONDA CIVIC 1999 6.G Workshop Manual lllustrated Index
t
Refer to the drawing below for transmission disassembly/reassembly.
Clean all the parts thoroughly in solvent and dry with compressed air.
I Luoricate att the pans with oil before

Page 635 of 2189

HONDA CIVIC 1999 6.G Workshop Manual Bolt SizeTorque Value
cn
E
F
6x1.0mm
6x1.0mm
8 x 1.0 mm
8 x 1.25 mm
8 x 1.25 mm
8 x 1,0 mm
12 N.m (1.2 kgnm, 8 lbfft)
15 N.m (1.5 kgfm, 11 lbf ft)
15 N.m (l.5 kgf.m, 11 lbift)
24 Nm (2.4 kgim, 17

Page 637 of 2189

HONDA CIVIC 1999 6.G Workshop Manual Reverse Shift Holder,
Reverse ldler Gear
Separate the transmission housing from the clutch
housing, and wipe it clean of the sealant.
Remove the 72 mm thrust shim and the oil guide
plate from the tran

Page 638 of 2189

HONDA CIVIC 1999 6.G Workshop Manual Reverse Shift Holder, Reverse ldler Gear
Clearance Inspection (contdl
3. Measure the clearance between the reverse
gear and the reverse shift holder.
Standard: 0.5 - 1.0 mm 10.02 - 0.04 inl
Service L

Page 639 of 2189

HONDA CIVIC 1999 6.G Workshop Manual Change Holder AssemblY
,Glearance InsPection
1.Measure the clearance between the shift piece and
the shift arm holder.
Standard: 0.1 - 0.3 mm {0.004 - 0.012 in)
service Limit: 0.6 mm {0.02 in)
lf the