Convertible Tops - 19
EM TOP INITIALIZATION
Initialization of the system is required for the CVM to learn the end limits of the top storage
cover. The CVM counts the pulses from the integrated hall sensor in the cover motor to
determine the cover position.
An initialization run occurs automatically after every eighth operation of the top. This
ensures that the hall sensor counting circuit is not adversely affected by any backlash or
elasticity of the top cover drive mechanism.
The hall sensor counter reading is
stored in a NV RAM, however it is
possible for this data to be incor-
rect or out of sync for the following
conditions:
Power supply interrupted while
top is in operation
Electrical failures that require
manual closing of the top.
Follow the procedures on this page
or refer to Group 54 in the Repair
Manual of TIS.
INITIALIZATION PROCEDURE
1. The top must be placed in the storage compartment
Motors engaged with the drives.
Top storage cover closed
2. Ignition key switched OFF.
3. Press and hold the top switch in the lowering direction.
4. Switch the ignition on (KL R).
5. After approximately 10 seconds the top storage cover will start to close and lock.
6. At this point release the the top switch. The initialization procedure will continue run-
ning. The procedure is complete approximately 0.5 seconds after the top storage cover
is closed and locked.
NOTE: The initialization procedure can be interrupted by switching the ignition off.