24-58
- Repair open circuit or short circuit if
necessary.
If no malfunctions are detected:
- Replace Fuel Pump (FP) relay -J17-.
- Re-connect Engine Control Module (ECM).
Check voltage supply for Fuel Pump (FP) and
components
- Remove fuses S228, S232, and S234 (positions 28, 32, and 34) from
fuse holder.
- Initiate output Diagnostic Test Mode (DTM) Page 01
-49
and activate
Evaporative Emission (EVAP) canister purge regulator valve -N80-.
- Connect multimeter for voltage measurement to Ground (GND) and to
one terminal of following fuses in fuse holder. Circlip
Specified value at one of the terminals
S228 approx. battery voltage
S232 approx. battery voltage
S234 approx. battery voltage
Pa
ge 67 of 81 Motronic fuel in
jection s
ystem, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.1
24-59
If specified values are not obtained:
- Repeat test at another terminal of fuse socket.
If specified values are not obtained again:
- Check wire connections.
Electrical Wiring Diagrams, Troubleshooting &
Component Locations If no malfunctions are detected:
- Replace Fuel Pump (FP) relay -J17-.
- Re-insert fuses.
Pa
ge 68 of 81 Motronic fuel in
jection s
ystem, servicin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.1