AUDI A6 1999 C5 / 2.G AEB Engine Motronic MFI And Ignition System 24-73
      
-  Check wiring for short circuit between ECM/test 
box and 2-pin harness connector according to 
wiring diagram. 
     
 
Connector terminal 1 to vehicle Ground
     
 Connector terminal

Page 105 of 135

AUDI A6 1999 C5 / 2.G AEB Engine Motronic MFI And Ignition System 24-78
      
-  Check battery positive voltage (B+) in display 
field 2. 
  
Display fields  
  
1   2   3   4  
Display group 4: Basic engine setting  
Display   xxx RPM   xx.xxx V  
xxx.x C  
xxx.x

Page 106 of 135

AUDI A6 1999 C5 / 2.G AEB Engine Motronic MFI And Ignition System 24-79
 Evaluation of display group 4  Display group: 4  
  
  
Display field: 2  
Possible cause  
Corrective action  
No VAG 1551 display  
Fuse for ECM faulty- Replace fuse
  Open circuit in wiring-

Page 115 of 135

AUDI A6 1999 C5 / 2.G AEB Engine Motronic MFI And Ignition System 24-84
       If the LED test light does not light up:  
     
-  Repeat test at other terminal of fuse 34.
    
If the LED test light does not light up:  
Checking fuel pump relay voltage supply  